USER’S MANUAL 

 

1.0

SUPERSERVER

®

1028UX-LL1-B8

1028UX-LL2-B8

1028UX-LL3-B8

Содержание SUPERSERVER 1028UX-LL1-B8

Страница 1: ...USER S MANUAL 1 0 SUPERSERVER 1028UX LL1 B8 1028UX LL2 B8 1028UX LL3 B8...

Страница 2: ...and is supplied only under a license Any use or reproduction of this product is not allowed except as expressly permitted by the terms of said license IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT...

Страница 3: ...ollow the procedures given in this chapter when installing removing or reconfiguring hardl drives and when replacing system power supply units and cooling fans Chapter 7 BIOS The BIOS chapter includes...

Страница 4: ...Interface 3 1 Overview 3 1 3 2 Control Panel Buttons 3 2 3 3 Control Panel LEDs 3 2 Overheating 3 3 3 4 Drive Carrier LEDs 3 4 3 5 Power Supply LEDs 3 4 Chapter 4 Standardized Warning Statements for...

Страница 5: ...d 6 7 6 7 System Cooling 6 8 System Fan Replacement 6 8 Installing the Air Shroud 6 10 6 8 Power Supply 6 11 Chapter 7 BIOS 7 1 Introduction 7 1 Starting BIOS Setup Utility 7 1 How To Change the Confi...

Страница 6: ...uds one for each CPU MCP 310 81907 0N Add on Riser Cards One AOC UR I4G Ultra riser card One AOC S3108L H8IR 16DD riser card One RSC R1UW 2E16 riser card One RSC R1UW E8R riser card SAS Accessories On...

Страница 7: ...guidelines ftp ftp supermicro com driver SAS LSI LSI_SAS_EmbMRAID_SWUG pdf Input Output The rear I O includes a VGA port a COM port two USB 3 0 ports quad Gb LAN ports and one dedicated IPMI LAN port...

Страница 8: ...VGA DDR3 NCSI LAN UART Onboard TPM Optional 1 4 Contacting Supermicro Headquarters Address Super Micro Computer Inc 980 Rock Ave San Jose CA 95131 U S A Tel 1 408 503 8000 Fax 1 408 503 8008 Email mar...

Страница 9: ...1 6 SUPERSERVER 1028UX LL1 B8 LL2 B8 LL3 B8 User s Manual Notes...

Страница 10: ...l noise and electromagnetic fields are generated A nearby grounded power outlet is required The box your chassis was shipped in should include two sets of rail assemblies two rail mounting brackets an...

Страница 11: ...e ambient temperature of the room Therefore consideration should be given to installing the equipment in an environment compatible with the manufacturer s maximum rated ambient temperature Tmra Reduce...

Страница 12: ...assis if you decide not to install it into a rack Figure 2 1 Identifying the Sections of the Rack Rails Figure 2 2 Installing the Inner Rail Extensions Installing the Optional Inner Rail Extensions At...

Страница 13: ...assembled outer rail includes a bracket with square pegs to fit into your rack holes If you have an older rack with round holes these brackets must be removed and you must use screws to secure the rai...

Страница 14: ...nto a Telco type rack use the two L shaped brackets on either side of the chassis four total First determine how far follow the server will extend out the front of the rack Larger chassis should be po...

Страница 15: ...2 10 SUPERSERVER 1028UX LL1 B8 LL2 B8 LL3 B8 User s Manual Notes...

Страница 16: ...ntrol panel on the front that houses power buttons and status monitoring lights Status lights on externally accessable hard drives Status lights for the power supply visible from the back of the chass...

Страница 17: ...erative fan Blinking red 0 25Hz Power failure check for a non operational power supply Solid blue Local UID has been activated Use this function to locate the server in a rack mount environment Blinki...

Страница 18: ...ED indicates a drive failure You should be notified by your system management software 3 5 Power Supply LEDs On the rear of the power supply module an LED displays the status Solid Green When illumina...

Страница 19: ...certified technicians should attempt to install or configure components Read this chapter in its entirety before installing or configuring components in the Supermicro chassis Some warnings may not ap...

Страница 20: ...g in den bersetzten Sicherheitshinweisen die zusammen mit diesem Ger t ausgeliefert wurden BEWAHREN SIE DIESE HINWEISE GUT AUF INSTRUCCIONES IMPORTANTES DE SEGURIDAD Este s mbolo de aviso indica pelig...

Страница 21: ...spositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l installation lectrique du local V rifiez qu...

Страница 22: ...t installeren of verwijderen van systeem onderdelen dient u alle spanningsbronnen en alle stroomkabels aangesloten op de voeding en van de behuizing te verwijderen Power Disconnection Warning Warnung...

Страница 23: ...d ha sido dise ada para instalaci n en reas de acceso restringido S lo puede obtenerse acceso a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio d...

Страница 24: ...el mismo tipo o el equivalente recomendado por el fabricante Desechar las bater as gastadas seg n las instrucciones del fabricante Waarschuwing Er is ontploffingsgevaar indien de batterij verkeerd ver...

Страница 25: ...servicing Waarschuwing Deze eenheid kan meer dan n stroomtoevoeraansluiting bevatten Alle aansluitingen dienen verwijderd te worden om het apparaat stroomloos te maken Warnung Dieses Ger t kann mehr...

Страница 26: ...elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Comply with Local and National Electrical Codes Warning Installation...

Страница 27: ...ntilateur Waarschuwing Het is mogelijk dat de ventilator nog draait tijdens het verwijderen van het ventilatorsamenstel uit het chassis Houd uw vingers schroevendraaiers en eventuele andere voorwerpen...

Страница 28: ...signated connection cables power cables and AC adaptors Using any other cables and adaptors could cause a malfunction or a fire Electrical Appliance and Material Safety Law prohibits the use of UL or...

Страница 29: ...4 20 SUPERSERVER 1028UX LL1 B8 LL2 B8 LL3 B8 User s Manual Notes...

Страница 30: ...uit boards it is important to handle them very carefully see Chapter 4 Also note that the size and weight of the serverboard can cause it to bend if handled improperly which may result in damage To pr...

Страница 31: ...lever labeled Open 1st OPEN1st OPEN1st Release the lever labeled Close 1st 2 Press the second load lever labeled Close 1st to release the load plate from its locked position 3 With the second lever f...

Страница 32: ...four mounting holes are aligned with those on the serverboard s and the heatsink bracket underneath 3 Screw in two diagonal screws until just snug to avoid possible damage to the CPU do not over tight...

Страница 33: ...8 UID Button UID LED 9 VGA Port 5 5 Installing Memory Note The system comes with memory already preinstalled Follow the instructions below when adding or replacing DIMMs Installing DIMMs 1 Push the r...

Страница 34: ...RST JVRM1 JVRM2 I2 C Bus for VRM Pins 1 2 BMC Normal Connector Description COM1 COM Serial Port 1 FAN1 FAN8 System Cooling Fan Header IPMI LAN Dedicated IPMI LAN Port I SATA0 5 SATA 3 0 Ports supporte...

Страница 35: ...AN port 1 are located on pins 11 and 12 of JF1 and the LED connection for GLAN Port 2 are on pins 9 and 10 Attach the NIC LED cables here to display network activity Refer to the table on the right fo...

Страница 36: ...backward compatible with tradi tional 3 pin fans Fan speed control is available for 4 pin fans only The fan speeds are controlled by thermal management via IPMI See the table on the right for pin defi...

Страница 37: ...r system SMB Header Pin Definitions Pin Definition 1 Data 2 Ground 3 Clock 4 No Connection 5 8 Jumper Settings Explanation of Jumpers To modify the operation of the serverboard jumpers can be used to...

Страница 38: ...n Pins 1 2 BMC Enable Pins 2 3 Normal I2 C Bus for VRM Jumpers JVRM1 and JVRM2 allow the BMC or the PCH to access CPU and memory VRM controllers See the table on the right for jumper set tings 5 9 Onb...

Страница 39: ...our serverboard Download this file to create a CD DVD of the drivers and utilities it contains You may also use a utility to extract the ISO file if preferred Another option is to go to the Supermicro...

Страница 40: ...t chassis intrusion for multiple systems with SuperDoctor 5 or IPMI SD5 Management Server monitors HTTP FTP and SMTP services to optimize the efficiency of your operation Note The default User Name an...

Страница 41: ...5 22 SUPERSERVER 1028UX LL1 B8 LL2 B8 LL3 B8 User s Manual Notes...

Страница 42: ...boards PCBs it is important to handle them very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a grounded wrist strap designed to...

Страница 43: ...m JF1 on the serverboard to the appropriate header on the Control Panel PCB printed circuit board Make sure the red wire plugs into pin 1 on both connectors Pull all excess cabling out of the airflow...

Страница 44: ...s during system operation Removing Drive Carriers from the Chassis 1 Press the release button on the drive carrier This extends the drive carrier handle 2 Use the handle to pull the drive carrier out...

Страница 45: ...The riser card bracket is toolless and has pins that snap into holes on the rear of the chassis Internal Expansion Card The pre installed Ultra Riser card that provides the four LAN ports may be repla...

Страница 46: ...check that the fan is working properly and that the LED on the control panel has turned off Finish by replacing the chassis cover 6 8 Fans in Housing 6 7 System Cooling Eight 4 cm counter rotating fan...

Страница 47: ...ement units can be ordered directly from Supermicro Replacing the Power Supply 1 Unplug the AC power cord from the failed power supply module 2 Push in the locking tab at the back of the module to rel...

Страница 48: ...6 12 SUPERSERVER 1028UX LL1 B8 LL2 B8 LL3 B8 User s Manual Notes...

Страница 49: ...plays all the options that can be configured Grayed out options cannot be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an ar...

Страница 50: ...IOS related issue In no event shall the manufacturer be liable for direct indirect special incidental or consequential damage arising from a BIOS update If you have to update the BIOS do not shut down...

Страница 51: ...ptors will capture Interrupt 19 at bootup and allow the drives that are attached to these host adaptors to func tion as bootable disks If this item is set to Disabled the ROM BIOS of the host adaptors...

Страница 52: ...lines for 128 bytes as comprised if this feature is set to Enabled DCU Streamer Prefetcher Available when supported by the CPU Select Enabled to enable the DCU Data Cache Unit Streamer Prefetcher whi...

Страница 53: ...QLRU Config 31 0 Hex This feature is set to 0 Advanced Power Management Configuration This section is used to configure the following CPU Power Management settings Power Technology Select Energy Effi...

Страница 54: ...ation Time Window This item indicates the time window over which time duration power should be maintained Package Clamping Limit1 Use this item to set the limit on power performance states for the run...

Страница 55: ...5 GT s Gen 2 Generation 2 5 GT s and Gen 3 Generation 3 8 GT s IOAT Intel IO Acceleration Configuration Enable IOAT Select Enable to enable Intel I OAT I O Acceleration Technology support which signif...

Страница 56: ...abled to enable data scrambling to enhance system performance and data integrity The options are Auto Disabled and Enabled DRAM RAPL Baseline Use this feature to set the run time power limit baseline...

Страница 57: ...or EFI applications only The options are Enabled Disabled and Auto XHCI Hand Off This is a work around solution for operating systems that do not support XHCI Ex tensible Host Controller Interface han...

Страница 58: ...ive The options are Hard Disk Drive and Solid State Drive If the item above Configure SATA as is set to IDE the following items will display Serial ATA Port 0 Port 5 This item indicates that a SATA po...

Страница 59: ...and Enabled sSATA Port 0 Port 1 Hot Plug Select Enabled to enable hot plugging support for a port specified by the user which will allow the user to replace a sSATA disk drive installed on this port...

Страница 60: ...bove 4G Decoding Available if the system supports 64 bit PCI decoding Select Enabled to decode a PCI device that supports 64 bit in the space above 4G Address The options are Enabled and Disabled SR I...

Страница 61: ...e user Change Port 1 Settings Change Port 2 Settings This feature specifies the base I O port address and the Interrupt Request address of Serial Port 1 or Serial Port 2 Select Auto for the BIOS to au...

Страница 62: ...The options are Dis abled and Enabled Legacy OS Redirection Resolution Use this item to select the number of rows and columns used in Console Redi rection for legacy OS support The options are 80x24...

Страница 63: ...olumns used in Console Redirection for legacy OS support The options are 80x24 and 80x25 Putty KeyPad This feature selects Function Keys and KeyPad settings for Putty which is a terminal emulator desi...

Страница 64: ...ect Enabled to activate the High Precision Event Timer HPET that produces periodic interrupts at a much higher frequency than a Real time Clock RTC does in synchronizing multimedia streams providing s...

Страница 65: ...tiple event counter wait before generating a new event log Enter a number between 0 to 99 The default setting is 60 Note Please reboot the system for the changes to take effect View SMBIOS Event Log T...

Страница 66: ...ll The options are Do Nothing and Erase Immediately Note After making changes on a setting be sure to reboot the system for the changes to take effect BMC Network Configuration The following items wil...

Страница 67: ...password at Setup Select Always for the system to prompt for a password at bootup and upon entering the BIOS Setup utility The options are Setup and Always Administrator Password Use this feature to s...

Страница 68: ...iver that the new boot option is added to Path for Boot Option This item is used to specify the path to the driver that the new boot option is added to The format for the path is fsx path filename efi...

Страница 69: ...lect this option to save all changes made This will not reset reboot the system Discard Changes Select this option and press Enter to discard all the changes and return to the AMI BIOS Utility Program...

Страница 70: ...ossible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list correspond to the number of beeps for the corresponding error BIOS Err...

Страница 71: ...A 2 SUPERSERVER 1028UX LL1 B8 LL2 B8 LL3 B8 User s Manual Notes...

Страница 72: ...mory Preinstalled memory eight 8 GB memory modules for a total of 64 GB DDR4 2400 MHz low profile registered ECC memory SATA Controller Ten SATA 3 0 ports RAID 0 1 5 and 10 supported Drive Bays The ch...

Страница 73: ...cm counter rotating cooling fans fan speed controlled by IPMI System Input Requirements AC Input Voltage 100 240 VAC Rated Input Current 9 5 4 5 Amps Rated Input Frequency 50 60 Hz Power Supply 80 plu...

Страница 74: ...B 4 SUPERSERVER 1028UX LL1 B8 LL2 B8 LL3 B8 User s Manual Notes...