background image

115

114

SuperServer 1019S-M2 User's Manual

Appendix B: Standardized Warning Statements

Backplane Voltage

バックプレーンの電圧

システムの稼働中は危険な電圧または電力が、バックプレーン上にかかっています。

修理する際には注意ください。

警告
当系统正在进行时,背板上有很危险的电压或能量,进行维修时务必小心。

警告
當系統正在進行時,背板上有危險的電壓或能量,進行維修時務必小心。

Warnung 
Wenn das System in Betrieb ist, treten auf der Rückwandplatine gefährliche Spannungen 
oder Energien auf. Vorsicht bei der Wartung.

¡Advertencia! 

Cuando el sistema está en funcionamiento, el voltaje del plano trasero es peligroso. Tenga 

cuidado cuando lo revise.

Attention 
Lorsque le système est en fonctionnement, des tensions électriques circulent sur le fond de 
panier. Prendre des précautions lors de la maintenance.

Warning! 

Hazardous voltage or energy is present on the backplane when the system 

is operating. Use caution when servicing.

 

ירוחאה לנפב חתמ

 

 

זא

!הרה

 

 ךלהמב רהזיהל שי .תכרעמה לועפת ןמזב ירוחאה לנפב חתמ תנכס תמייק

.הדובעה

 

Comply with Local and National Electrical Codes

地方および国の電気規格に準拠

機器の取り付けはその地方および国の電気規格に準拠する必要があります。

Warnung 
Die Installation der Geräte muss den Sicherheitsstandards entsprechen.

¡Advertencia! 
La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales.

كانه

 

زطخ

 

هم

 

يئابزهكلا رايتلا

 

ىلع ةدىجىملا ةقاطلاوأ

 

ةحىللا

 

 نىكي امدنع

ماظنلا

 

لمعي

 

دنع ارذح هك

 

ةمدخ

 

ساهجلا اذه

 

 

경고!

시스템이 동작 중일 때 후면판 (Backplane)에는 위험한 전압이나 에너지가 발생 합니다. 
서비스 작업 시 주의하십시오. 

Waarschuwing 

Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in 
gebruik is. Voorzichtigheid is geboden tijdens het onderhoud.

Attention 
L'équipement doit être installé conformément aux normes électriques nationales et locales.

警告

设备安装必须符合本地与本国电气法规。

警告

設備安裝必須符合本地與本國電氣法規。

Warning! 

Installation of the equipment must comply with local and national electrical 

codes.

Содержание SuperServer 1019S-M2

Страница 1: ...nce when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s...

Страница 2: ...o website for possible updates to the manual revision level Warnings Special attention should be given to the following symbols used in this manual Warning Indicates high voltage may be encountered wh...

Страница 3: ...ower Cables 48 4 3 Ports 49 Rear I O Ports 49 4 4 Jumpers 51 Explanation of Jumpers 51 4 5 LED Indicators 54 Chapter 5 Software 5 1 OS Installation 56 Installing the Windows OS for a RAID System 56 In...

Страница 4: ...V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermi...

Страница 5: ...Appendix B Main Parts List Description Part Number Quantity Heatsink passive SNK P0046P 1 Cooling Fans FAN 0156L4 4 Bracket for Two Fixed 2 5 Internal Hard Drives MCP 220 51401 0N 1 Riser Card RSC RR...

Страница 6: ...fore servicing Figure 1 1 Control Panel View 1 4 Server Chassis Features Control Panel The switches and LEDs located on the control panel are described below See Chapter 4 for more details on the cont...

Страница 7: ...PCI E 3 0 X4 IN X8 DP1 DP2 VGA DVI LAN3 4 LAN1 2 USB2 3 3 0 IPMI_LAN USB0 1 1 1 1 1 1 1 1 1 1 X11SSZ F REV 1 02 MAC CODE MAC CODE MAC CODE MAC CODE MAC CODE BAR CODE DESIGNED IN USA BIOS LICENSE CPU S...

Страница 8: ...ts I SGPIO1 Serial Link General Purpose I O Header J15 4 pin Connector for HDD to provide power from the motherboard to onboard devices J18 Extended CMOS Battery Connector JD1 Speaker Buzzer Header JF...

Страница 9: ...GT s SVID IMVP8 DDR4 CHA DIMMA1 DDR4 CHB DIMMB1 2133 1866 1600MHz 8GT s x4 DMI SATA III 6Gb s 4 X SATA III RJ45 2 5GT s I219V PCH H C236 Q170 Socket H4 Audio Pin Header AZALIA Realtek ALC888S VD2 RJ45...

Страница 10: ...on the bottom of the rack are extended to the floor so that the full weight of the rack rests on them In single rack installations stabilizers should be attached to the rack In multiple rack in stall...

Страница 11: ...nent at the bottom of the rack If the rack is provided with stabilizing devices install the stabilizers before mounting or servicing the unit in the rack 2 3 Installing the Rails There are a variety o...

Страница 12: ...rack first Installing the Outer Rails onto the Rack Each end of the assembled outer rail includes a bracket with square pegs to fit into your rack holes If you have an older rack with round holes thes...

Страница 13: ...he front of the server to the rack Figure 2 3 Installing the Server into a Rack Figure 2 4 Installing the Server into a Telco Rack Installing the Server into a Telco Rack Optional brackets p n MCP 290...

Страница 14: ...n removing or installing non hot swap components or when replacing a non redundant power supply 1 Use the operating system to power down the system 2 After the system has completely shut down disconne...

Страница 15: ...from its locked position Load Lever Load Plate Bottom Edge Top Edge 2 Gently lift the load lever to open the load plate Remove the plastic cover plate 3 Use your thumb and your index finger to hold th...

Страница 16: ...t drop the processor on the socket move or rub the processor against the socket or against any socket pins which may damage the components Figure 3 5 Installing Removing the Heatsink Figure 3 4 Inspec...

Страница 17: ...le press it straight down into the slot until the module snaps into place 4 Press the release tabs to the locked positions to secure the DIMM module into the slot Repeat for other DIMM slots as needed...

Страница 18: ...ttery must be replaced only with the same or an equivalent type recommended by the manufacturer CR2032 Figure 3 9 Populating DIMMs PCI Expansion Card Installation The system includes a pre installed r...

Страница 19: ...ently pulling it out of the housing 5 Place the new fan into the vacant space in the housing Make sure that the arrows on the sides of the fan indicating air direction point in the same direction as t...

Страница 20: ...ate at a 100V 240V input voltage When only one power supply is deployed it is installed in the right power bay when viewed from the rear with the left bay occupied by a dummy power supply For redundan...

Страница 21: ...and the 8 pin power connectors to the power supply Failure to do so may void the manufacturer s warranty on your power supply and motherboard ATX Power 24 pin Connector Pin Definitions Pin Definition...

Страница 22: ...ions Pin Definition Pin Definition 1 LCLK 2 GND 3 LFRAME 4 No Pin 5 LRESET 6 5V X 7 LAD3 8 LAD2 9 3 3V 10 LAD1 11 LAD0 12 GND 13 SMB_CLK4 X 14 SMB_DAT4 X 15 P3V3_STBY 16 SERIRQ 17 GND 18 GND 19 P3V3_S...

Страница 23: ...has been opened Chassis Intrusion Pin Definitions Pins Definition 1 Intrusion Input 2 Ground Power SMB I2 C Header Power System Management Bus I2 C header at JPI2 C1 monitors the power supply fan and...

Страница 24: ...d Figure 4 1 JF1 Control Panel Pins Control Panel JF1 contains header pins for various control panel connections See the figure below for the pin locations and definitions of the control panel buttons...

Страница 25: ...cable to pins 7 and 8 of JF1 to use the Overheat Fan Fail LED connections NIC1 NIC2 LAN1 LAN2 The NIC Network Interface Controller LED connection for LAN port 1 is located on pins 11 and 12 of JF1 and...

Страница 26: ...Pin Definitions JF1 Pin Definition 19 Control 20 Ground 4 3 Ports Serial Ports Two COM ports COM1 COM2 are provided on the motherboard Both are located near the PCI E slot 4 Rear I O Ports See the fig...

Страница 27: ...layPorts located on the rear I O back panel DisplayPort developed by the VESA consortium delivers digital display at a fast refresh rate It can connect to virtually any display using a DisplayPort ada...

Страница 28: ...h Dog Jumper Settings Jumper Setting Definition Pins 1 2 Reset Pins 2 3 NMI Open Disabled SMBus to PCI E Slots Use jumpers JI2 C1 and JI2 C2 to connect the System Management Bus I2 C to PCI Express sl...

Страница 29: ...dentified Unit ID LED A rear UID LED LED1 is located next to the I O back panel This UID indicator provides easy identification of a system unit that may be in need of service Refer to the table for t...

Страница 30: ...Windows OS Setup screen will display 3 From the Windows OS Setup screen press the Enter key The OS Setup will automatically load all device files and then continue with the Windows installation 4 Aft...

Страница 31: ...th SuperDoctor 5 Management Server SSM Server you can remotely control power on off and reset chassis intrusion for multiple systems with SuperDoctor 5 or IPMI SuperDoctor 5 Management Server monitors...

Страница 32: ...ages built in We retain the option to include omit or change any of these text messages Settings printed in Bold are the default values A indicates a submenu Highlighting such an item and pressing the...

Страница 33: ...evert to the default to the manufacture default settings Boot Feature Quiet Boot Use this feature to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to...

Страница 34: ...or more than 5 minutes The options are Enabled and Disabled Power Button Function This feature controls how the system shuts down when the power button is pressed Select 4_Seconds_Override for the use...

Страница 35: ...to reduce power consumption and heat dissipation The options are Disabled and Enabled Turbo Mode Select Enabled for processor cores to run faster than the frequency specified by the manufacturer The o...

Страница 36: ...Warning Setting the wrong values in the following features may cause the system to malfunc tion System Agent SA Configuration The following System Agent information will display System Agent Bridge N...

Страница 37: ...setting is 75 SLOT6 Power Limit Scale Use this feature to select the scale used for the slot power limit value The options are 1 0x 0 1x 0 01x and 0 001x Program PCIe ASPM After OPROM PCIe ASPM the A...

Страница 38: ...for a PCI E device Select Auto for the system BIOS to automatically set the ASPM level based on the system configuration Select Disabled to disable ASPM support The options are Disabled L0s L1 L0s L1...

Страница 39: ...device The options are Enabled and Disabled Port 0 Port 3 SATA Device Type Use this item to specify if the SATA port specified by the user should be connected to a Solid State drive or a Hard Disk Dr...

Страница 40: ...ws the user the configure settings of Serial Port 1 Serial Port 1 Select Enabled to enable the selected onboard serial port The options are Enabled and Disabled Logical Device Settings This item displ...

Страница 41: ...Select ANSI to use the Extended ASCII Character Set Select VT UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes The options are VT100 VT100 VT UTF8 and ANSI COM1 Bits Per sec...

Страница 42: ...transmission speed for a serial port used in Console Redirection Make sure that the same speed is used in the host computer and the client computer A lower transmission speed may be required for long...

Страница 43: ...ake sure that the same speed is used in the host computer and the client computer A lower transmission speed may be required for long and busy lines The options are 9600 19200 57600 and 115200 bits pe...

Страница 44: ...ce the name of the iSCSI Initiator is entered into the system configure the proper settings for the following items Add an Attempt Delete Attempts Change Attempt order Intel I210 Gigabit Network Conne...

Страница 45: ...ect a value UEFI Driver This item displays the UEFI driver version Adapter PBA This item displays the Processor Bus Adapter PBA model number The PBA number is a nine digit number i e 010B00 000 locate...

Страница 46: ...ly for all messages to be automatically erased from the event log when the event log memory is full The options are Do Nothing and Erase Immediately SMBIOS Event Long Standard Settings Log System Boot...

Страница 47: ...e to reboot the system for the changes to take effect BMC Network Configuration BMC Network Configuration The BMC network information is only valid when the IPMI Function is enabled IPMI LAN Selection...

Страница 48: ...ter power on time wthout using Supermicro Update Manager SUM or extended IPMI features The BMC network configuration in the BIOS setup is also invalid when IPMI Function Support is disabled The genera...

Страница 49: ...re Yes and No Key Exchange Key Set New Key Select Yes to load the KEK from the manufacturer s defaults Select No to load the KEK from a file The options are Yes and No Append Key Select Yes to add the...

Страница 50: ...UEFI Dual Boot Option 6 Legacy UEFI Dual Boot Option 7 Legacy UEFI Dual Boot Option 8 Legacy UEFI Dual Boot Option 9 Legacy UEFI Dual Boot Option 10 Legacy UEFI Dual Boot Option 11 Legacy UEFI Dual Bo...

Страница 51: ...anges you have made This will not reset reboot the system Discard Changes Select this option and press Enter to discard all the changes and return to the AMI BIOS utility Program Default Options Resto...

Страница 52: ...hose which will not allow the system to continue the boot up procedure If a fatal error occurs you should consult with your system manufacturer for possible repairs These fatal errors are usually comm...

Страница 53: ...mit den Gefahren elektrischer Schaltungen und den blichen Verfahren zur Vorbeugung vor Unf llen vertraut Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen berse...

Страница 54: ...DEZE INSTRUCTIES Installation Instructions Warning Read the installation instructions before connecting the system to the power source Warnung Vor dem Anschlie en des Systems an die Stromquelle die I...

Страница 55: ...che installatie Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 250V 20A Power Disconnection Warning Warnung Das System muss von allen Quellen der Energie und vom Netzanschluss...

Страница 56: ...dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o utilizar este equipo Restricted Area Waarschuwi...

Страница 57: ...alleen verkregen worden door gebruik te maken van speciaal gereedschap slot en sleutel of andere veiligheidsmaatregelen Battery Handling Warnung Bei Einsetzen einer falschen Batterie besteht Explosion...

Страница 58: ...e unit Warnung Dieses Ger t kann mehr als eine Stromzufuhr haben Um sicherzustellen dass der Einheit kein trom zugef hrt wird m ssen alle Verbindungen entfernt werden Waarschuwing Deze eenheid kan mee...

Страница 59: ...enance Warning Hazardous voltage or energy is present on the backplane when the system is operating Use caution when servicing Comply with Local and National Electrical Codes Warnung Die Installation...

Страница 60: ...rtencia Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales Waarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemmi...

Страница 61: ...nschlusskabel Stromkabel und Netzteile Verwendung anderer Kabel und Adapter kann zu einer Fehlfunktion oder ein Brand entstehen Elektrische Ger te und Material Safety Law verbietet die Verwendung von...

Страница 62: ...appareils lectriques que les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA UL CSA Supermicro UL CSA AC Electrical Appliance and Material Safety Law UL CSA UL CSA Waarschuwing Bij het...

Страница 63: ...5 SATA drives PCI Expansion Slots One PCI Express 3 0 x4 in x8 slot PCH Slot 4 One PCI Express 3 0 x16 CPU Slot 6 with riser card installed One PCI Express 3 0 x4 in x8 slot PCH Slot 7 Motherboard X11...

Страница 64: ...EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe Perchlorate Warning California Best Management Practices R...

Отзывы: