background image

SuperServer 1019D-(12C/14C/16C-)FRN5TP User's Manual

76

JSLOT1 ~ JSLOT4 OPROM

Use this feature to select which firmware type to be loaded for the add-on card in this slot. 

The options are Disabled, 

Legacy PXE

, EFI, and Legacy iSCSI.

Onboard Video Option ROM

Use this feature to select the onboard Video Option ROM type. The options are Disabled, 

Legacy,

 and EFI.

Onboard 1G LAN OPROM

Use this feature to select which firmware type to be loaded for onboard 1G LAN devices. 

The options 

Legacy

 and EFI.

Onboard 10G LAN OPROM

Use this feature to select which firmware type to be loaded for onboard 1G LAN devices. 

The options 

Legacy

 and EFI.

Onboard LAN1 OPROM

Use this feature to select which firmware function to be loaded for the specified LAN port 

used for system boot. The options are 

Disabled

, Legacy, and EFI.

Onboard LAN2 OPROM

Use this feature to select which firmware function to be loaded for the specified LAN port 

used for system boot. The options are 

Disabled

, Legacy, and EFI.

Onboard LAN3 OPROM

Use this feature to select which firmware function to be loaded for the specified LAN port 

used for system boot. The options are Disabled, 

Legacy

, and EFI.

Onboard LAN4 OPROM

Use this feature to select which firmware function to be loaded for the specified LAN port 

used for system boot. The options are 

Disabled

, Legacy, and EFI.

Network Stack Configuration

Network Stack

Select Enabled to enable PXE (Preboot Execution Environment) or UEFI (Unified Extensible 

Firmware Interface) for network stack support. The options are 

Enabled

 and Disabled.

*If the feature above is set to Enabled, the next six features will be available for 

configuration:

Ipv4 PXE Support

Select Enabled to enable IPv4 PXE boot support. The options are Disabled and 

Enabled

.

Содержание SuperServer 1019D-12C-FRN5TP

Страница 1: ...USER S MANUAL Revision 1 0b SuperServer 1019D FRN5TP 1019D 12C FRN5TP 1019D 14C FRN5TP 1019D 16C FRN5TP B...

Страница 2: ...commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful in...

Страница 3: ...necessary drivers utilities and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities https www supermicro com wftp Product...

Страница 4: ...g for Setup 20 Choosing a Setup Location 20 Rack Precautions 20 Server Precautions 21 Rack Mounting Considerations 21 Ambient Operating Temperature 21 Reduced Airflow 21 Mechanical Loading 21 Circuit...

Страница 5: ...Checking the Server s Airflow 38 Power Supply 39 Installing an Optional Hard Drive 40 Chapter 4 Motherboard Connections 4 1 Power Connections 42 4 2 Headers and Connectors 43 4 3 Jumpers 47 Explanatio...

Страница 6: ...Server 1019D 12C 14C 16C FRN5TP User s Manual Appendix A BIOS Error Codes Appendix B Standardized Warning Statements for AC Systems Appendix C UEFI BIOS Recovery Instructions Appendix D System Specifi...

Страница 7: ...puter B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma...

Страница 8: ...90 00102 0N MCP 290 00108 0B 2 sets SuperServer Model Variation Table SuperServer Model Motherboard Model Processor Name 1019D FRN5TP X11SDS 8C D 2146NT 1019D 12C FRN5TP X11SDS 12C D 2163IT 1019D 14C...

Страница 9: ...Maximum Memory Speed 2133MHz 2133MHz 2133MHz 2400MHz Embedded Options Available Yes Yes Yes Yes Intel Hyper Threading Technology Yes Yes Yes Yes Intel Virtualization Technology VT x Yes Yes Yes Yes I...

Страница 10: ...a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the server It should be situated in a clean dust free area that is well ventilated Avoi...

Страница 11: ...ECC LRDIMM DDR4 memory Speed of up to 2133MHz for 1019D FRN5TP 1019D 12C FRN5TP and 1019D 14C FRN5TP Speed of up to 2400MHz for 1019D 16C FRN5TP Chipset System on Chip Expansion Slots Two M 2 M Key 22...

Страница 12: ...C 14C 16C FRN5TP User s Manual System Features Power 400W AC DC 80 Platinum level Cooling Five 40 x 40 x 56 mm 13K 11K RPM counter rotating fans Form Factor 1U rackmount Dimensions WxHxD 17 2 x 1 7 x...

Страница 13: ...p to four AIOM modules chassis comes with four dummy covers up to two EDSFF modules chassis comes with two dummy trays Control Panel Power switches and status LEDs are located on the control panel on...

Страница 14: ...le interface 5 10G GbE Ports 1 and 2 One 10G GbE ports that can function as IPMI ports to access the system The system does not need to be turned on for this feature 6 SFP Ports 1 and 2 Small Form fac...

Страница 15: ...ition 1Hz Blinking Red The node is detecting a fan failure 25Hz Blinking Red The node is detecting a power failure Solid Blue The node local UID is on 1Hz Blinking Blue The node remote UID is on No Il...

Страница 16: ...OS LICENSE 1 C A C A X11SDS 8C REV 1 01 DESIGNED IN USA 10G MAC E KEY B KEY M KEY M KEY SRW6 SRW1 PWR1 PWR2 JMD3 JMD4 JEDSFF1 JEDSFF2 JSLOT4 JSLOT3 JSLOT2 JSLOT1 JPWRST JRK1 JP1 BT1 JBT1 JMA1 JSIM1 JL...

Страница 17: ...EDSFF1 JEDSFF2 EDSFF Short Header Shared with M 2 M Keys JL1 Chassis Intrusion Header JMA1 Receptacle for AOM SMF TP4F JMD1 M 2 Slot E Key 2230 PCI E 3 0 x2 USB2 0 JMD2 M 2 Slot B Key 2242 3042 PCI E...

Страница 18: ...3 0 Port JLAN2 Dual 10G RJ45 Ports JMA1 Receptacle for X11SDS 8C 16C JSFP1 Dual 10G SFP Ports JUSB1 Micro USB Serial Console Port Shared with Serial Console Port PWR1 PWR2 Bus Bar Connector BAR CODE D...

Страница 19: ...HUB USB2 0 X 1 DEFAULT CPU D 2146 NT USB2 0 X 4 JMP TO DISABLE DEFAULT DEFAULT UART JMP TO DISABLE TRANCEIVER UART AOM SMF TP4F 4x SIOM 2x4 EACH PCIe3 0 8 x4 USB3 0 X 2 SPI 2 USB 3 0 PORTS PCH 2666 2...

Страница 20: ...t free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated It will also require a grounded AC power outlet nearby Leave enough clearance in fr...

Страница 21: ...o keep your system operating in case of a power failure Allow any drives and power supplies to cool before touching them When not servicing always keep the front door of the rack and all covers panels...

Страница 22: ...r supply connections other than the direct connections to the branch circuit e g the use of power strips etc To prevent bodily injury when mounting or servicing this unit in a rack you must take speci...

Страница 23: ...sembly consists of two sections an inner fixed chassis rail that secures directly to the server chassis and an outer fixed rack rail that secures directly to the rack itself Inner Rails Inner rail is...

Страница 24: ...s is simple and can be accomplished with a standard head screwdriver Installing the Inner Rails 1 Place the inner rail on the side of the chassis aligning the hooks of the chassis with the inner rail...

Страница 25: ...s of the rail with the slides The ends of each bracket must angle in the same direction 2 Adjust both the short and long brackets to the proper distance so that the rail fits snuggly into the rack 3 S...

Страница 26: ...k rails 3 Slide the chassis rails into the rack rails keeping the pressure even on both sides It may be necessary to depress the locking tabs when inserting When the server has been pushed completely...

Страница 27: ...e removed from the system Please follow the procedures given in each section 3 1 Removing Power Use the following procedure to ensure that power has been removed from the system This step is necessary...

Страница 28: ...he Top Cover 1 Remove the power from the system as described in Section 3 1 2 Remove the two screws securing the cover to the chassis See Figure 3 1 3 Slide the cover back toward the rear of the chass...

Страница 29: ...ed memory which will improve memory performance Check the Supermicro website for possible updates to memory support DIMM Module Population Configuration For optimal memory performance follow the table...

Страница 30: ...ormance install DIMM modules in pairs to activate memory interleaving 1 A B C D E F G H 1 S N CODE IPMI CODE S N LABEL BIOS LICENSE 1 C A C A X11SDS 8C REV 1 01 DESIGNED IN USA 10G MAC E KEY B KEY M K...

Страница 31: ...ey of the DIMM with the receptive point on the memory slot and with your thumbs on both ends of the module press it straight down into the slot until the module snaps into place 4 Push the release tab...

Страница 32: ...ry 1 Remove power from the system as described in section 3 1 and remove the node from the chassis 2 Push aside the small clamp that covers the edge of the battery When the battery is released lift it...

Страница 33: ...AIOM and EDSFF in the chassis Removing the Dummy Device from the Chassis 1 Remove the dummy AIOM insert from the front side of the chassis by holding the lever and gently pulling the insert out from...

Страница 34: ...dummy AIOM insert is removed the Supermicro AIOM network module may be installed 2 Gently slide the AIOM module into the slot by aligning the PCB edge into the chassis rail 3 Once the AIOM module is...

Страница 35: ...g loaded push pin Push the pin inward to engage with the chassis 5 Slide the lock on the metal bracket to the right This prevents the push pin from accidental release 6 Optional Secure the AIOM module...

Страница 36: ...1 Once the dummy EDSFF insert is removed the Supermicro EDSFF network module may be installed 2 Gently slide the EDSFF module into the slot 3 Once the EDSFF module is inserted gently push the module i...

Страница 37: ...termine which fan requires changing Never run the server for an extended period of time with the chassis open 2 Power down the system as described in section 3 1 3 Remove the failed fan s cable from t...

Страница 38: ...te the server without the AIOM module or AIOM dummy insert and EDSFF drives or EDSFF dummy insert Use only recommended parts Make sure no wires or foreign objects obstruct airflow through the chassis...

Страница 39: ...illuminated on the power supply when the power is off An illuminated green light indicates that the power supply is operating New units can be ordered directly from Supermicro or authorized distribut...

Страница 40: ...re the drive s to the enclosure with four screws 2 Secure the HDD enclosure to the top side of the motherboard 3 Connect HDD cabling Figure 3 9 Inserting a 2 5 Hard Drive to the Mounting Enclosure HDD...

Страница 41: ...ting Enclosure with Hard Drive to the top side of the Motherboard Screws Screws Caution Do not unplug or pull the cables around the drive bay when the enclosure screws are not secured to the system Un...

Страница 42: ...he safety precautions in Appendix B before installing or removing components 4 1 Power Connections 12V Power Connector JPWR1 is the 12V DC power connector that provides power to the motherboard if use...

Страница 43: ...1 Ground Black 2 2 5A 12V Red 3 Tachometer 4 PWM_Control Chassis Intrusion A Chassis Intrusion header is located at JL1 on the motherboard Attach the appropriate cable from the chassis to inform you o...

Страница 44: ...B 3 0 Gen 1 Type A Pin Definitions Pin Definition Pin Definition 1 VBUS 5 SSRX 2 USB_N 6 SSRX 3 USB_P 7 GND 4 GND 8 SSTX 9 SSTX Universal Serial Bus USB Ports The motherboard has one front access USB...

Страница 45: ...d with a right angle connector the EDSFF Short device allows better airflow in a 1U server set up JEDSFF1 JEDSFF2 each offers PCI E3 0 x4 lanes for the latest low latency NVMe storage module Please no...

Страница 46: ...Indicator A Unit Identifier UID LED indicator is located on the control panel and motherboard and the switch is only located on the motherboard Note UID can also be triggered via IPMI on the control p...

Страница 47: ...etting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear the CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidental clearing of the CMOS Note Sh...

Страница 48: ...per Settings Jumper Setting Definition Pins 1 2 BMC Normal Pins 2 3 PCH Watch Dog JWD1 controls the Watch Dog function Watch Dog is a monitor that can reboot the system when a software application han...

Страница 49: ...N3 IPMI LAN Enable Disable Jumper Settings Jumper Setting Definition Pins 1 2 Enabled Default Pins 2 3 Disabled TPM Enable Disable Use JPT1 to enable or disable support for the TPM module Refer to the...

Страница 50: ...n this LED is lit it means power is present on the motherboard In suspend mode this LED will blink on and off Be sure to turn off the system and unplug the power cord s before removing or installing c...

Страница 51: ...g the website go into the CDR_Images in the parent directory of the above link and locate the ISO file for your motherboard Download this file to create a DVD of the drivers and utilities it contains...

Страница 52: ...one at a time After installing each item you must re boot the system before moving on to the next item on the list The bottom icon with a CD on it allows you to view the entire contents When making a...

Страница 53: ...and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server you can remotely control power on off and reset chassis intrusion for multiple syst...

Страница 54: ...IPMI IPMI is used to provide remote access monitoring and management There are several BIOS settings that are related to IPMI IPMI management is supported when the lower 10G LAN port is connected Fig...

Страница 55: ...as F1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be...

Страница 56: ...Date or System Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in MM DD YYYY format The time is enter...

Страница 57: ...ter 6 UEFI BIOS 57 Memory Information Total Memory This feature displays the total size of memory available in the system Memory Speed This feature displays the speed of the memory detected by the sys...

Страница 58: ...ootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the normal POST messages The options are Disabled and Enabled Option ROM Messages Use this feature...

Страница 59: ...on If enabled the Watch Dog timer will allow the system to reboot when it is inactive for more than five minutes The options are Disabled and Enabled Power Button Function This feature controls how th...

Страница 60: ...e CPU Set to Enable for Execute Disable Bit support which will allow the processor to designate areas in the system memory where an application code can execute and where it cannot thus preventing a w...

Страница 61: ...Enable for DCU Data Cache Unit IP Prefetcher support which will prefetch IP addresses to improve network connectivity and system performance The options are Enable and Disable LLC Prefetch If set to E...

Страница 62: ...Performance Balanced Power and Power CPU P State Control Use this submenu to configure the following CPU power settings SpeedStep Pstates Intel SpeedStep Technology allows the system to automatically...

Страница 63: ...Disable and Enable This feature must be set to Disable to be able to configure the next two features CPU C6 report Select Enable to allow the BIOS to report the CPU C6 State ACPI C3 to the operating s...

Страница 64: ...his feature to enable or disable data scrambling for DDR4 memory The options are Auto Disable and Enable tCCD_L Relaxation Select Auto to get TCDD settings from SPD Serial Presence Detect into memory...

Страница 65: ...given time The default setting is 100 SDDC Single device data correction 1 SDDC Plus One organizes data in a single bundle x4 x8 DRAM If any or all of the bits become corrupted corrections occur The x...

Страница 66: ...ifuraction setting for a PCI E port speci fied by the user The options are x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 and Auto IOU1 II0 PCIe Br2 Use this feature to configure the PCI E port Bifuraction setting f...

Страница 67: ...ort which will allow certain transac tions to violate the strict ordering rules of PCI bus for a transaction to be completed prior to other transactions that have already been enqueued The options are...

Страница 68: ...o enhance system performance The options are Enable and Disable Intel VMD Technology Note After you ve enabled VMD on a PCI E slot of your choice this PCI E slot will be dedicated for NVMe storage dev...

Страница 69: ...t up the VMD configuration BAR attribute The options are 32 bit prefetchable 64 bit non prefetchable and 64 bit prefetchable VMD Config for PStack1 Intel VMD for Volume Management Device Select Enable...

Страница 70: ...it prefetchable VMD Config for PStack2 Intel VMD for Volume Management Device Select Enable to use the Intel Volume Management Device Technology for this stack The options are Disable and Enable If th...

Страница 71: ...idge Configuration The following South Bridge information will display USB Module Version USB Devices Legacy USB Support Select Enabled to support onboard legacy USB devices Select Auto to disable leg...

Страница 72: ...The options are Disable and Enable If the feature above is set to Enable SATA HDD Unlock is available for configuration Configure sSATA as Select AHCI to configure an sSATA drive specified by the use...

Страница 73: ...w the user to replace a SATA drive without shutting down the system The options are Disable and Enable SATA Port 0 4 Spin Up Device Set this feature to enable or disable the PCH to initialize the devi...

Страница 74: ...n I O activity resumes The op tions are Disable and Enable sSATA RAID Option ROM UEFI Driver Select UEFI to load the EFI driver for system boot Select Legacy to load a legacy driver for system boot Th...

Страница 75: ...emory size according to memory address mapping for the IO hub The options are 1G 4G 16G 64G 256G and 1024G PCI PERR SERR Support Use this feature to enable or disable the runtime event for PCI errors...

Страница 76: ...options are Disabled Legacy and EFI Onboard LAN2 OPROM Use this feature to select which firmware function to be loaded for the specified LAN port used for system boot The options are Disabled Legacy a...

Страница 77: ...g is 1 Super IO Configuration Super IO Chip AST2500 Serial Port 1 Configuration Serial Port 1 Select Enabled to enable the onboard serial port specified by the user The options are Disabled and Enable...

Страница 78: ...11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 and IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Serial Port 2 Attribute Select SOL to use COM Port 2 as a Serial Over LAN SOL port for console redirection The options are...

Страница 79: ...ptions are None Even Odd Mark and Space Stop Bits A stop bit indicates the end of a serial data packet Select 1 Stop Bit for standard serial data communication Select 2 Stop Bits if slower devices are...

Страница 80: ...r a serial port used in Console Redirection Make sure that the same speed is used in the host computer and the client computer A lower transmission speed may be required for long and busy lines The op...

Страница 81: ...port The options are Disabled and Enabled Putty KeyPad This feature selects Function Keys and KeyPad settings for Putty which is a terminal emulator designed for the Windows OS The options are VT100 L...

Страница 82: ...ns are COM1 and SOL COM2 Terminal Type Use this feature to select the target terminal emulation type for Console Redirection Select VT100 to use the ASCII character set Select VT100 to add color and f...

Страница 83: ...viding smooth playback and reducing the dependency on other timestamp calculation devices such as an x86 RDTSC Instruction embedded in the CPU The High Performance Event Timer is used to replace the 8...

Страница 84: ...ement hierarchy for privacy control The options are Disabled and Enabled PH Randomization Use this feature to disable or enable Platform Hiearchy PH Randomization The options are Disabled and Enabled...

Страница 85: ...y are detected by the system Note After you ve enabled VMD on a PCI E slot of your choice this PCI E slot will be dedicated for NVMe storage devices use only and it will no longer support PCI E de vic...

Страница 86: ...lled in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at boot up The options are Disabled and Enabled Erasing Settings Erase SEL Se...

Страница 87: ...n IPMI Network Link Status Station MAC address VLAN IPv4 Address Source Station IP Address Subnet mask Gateway IP address IPV6 address status Station IPV6 address IPV6 Router IP Address Prefix Length...

Страница 88: ...the network that is attached to and request the next available IP address for this computer The options are Static and DHCP If the feature above is set to Static the Station IP Address Subnet Mask Ga...

Страница 89: ...st Configuration Protocol server in the network that is attached to and request the next available IP address for this computer The options are Unspecified Static and DHCP If the feature above is set...

Страница 90: ...rom three to 20 characters long User Password Use this feature to set the user password to enter the BIOS setup utility Password Check Select Setup for the system to check for a password at Setup Sele...

Страница 91: ...Management settings Factory Key Provision Select Enabled to install the default Secure Boot keys set by the manufacturer The options are Disabled and Enabled If the feature above is set to Enabled all...

Страница 92: ...efault db or No to load from a file on an external media Append Select Yes to add the db from the manufacturer s defaults list to the existing db Select No to load the db from a file The options are Y...

Страница 93: ...ate Select Yes to load a factory default dbr or No to load from a file on an external media Append Select Yes to add the dbr from the manufacturer s defaults list to the existing dbr Select No to load...

Страница 94: ...elect Enabled to erase all error events in the SMBIOS System Management BIOS log before an event logging is initialized at bootup The options are No Yes Next reset and Yes Every reset When Log is Full...

Страница 95: ...een 1 to 255 The default setting is 1 METW Multiple Event Count Time Window This feature is used to determine how long in minutes the multiple event counter should wait before generating a new event l...

Страница 96: ...GACY to EFI Support Select Enabled to boot EFI OS support after Legacy boot order has failed The options are Disabled and Enabled Fixed BOOT ORDER Priorities This option prioritizes the order of boota...

Страница 97: ...he boot priority list Delete Driver Option Use this feature to remove an EFI driver option from the driver order UEFI Application Boot Priorities Boot Option This feature sets the system boot order of...

Страница 98: ...Select Discard Changes and Exit from the Exit menu and press Enter Save Changes and Reset When you have completed the system configuration changes select this option to save all changes made and rese...

Страница 99: ...faults from the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults from the Exi...

Страница 100: ...m to continue the boot up procedure If a fatal error occurs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audibl...

Страница 101: ...com support manuals AMI BIOS POST Codes User s Guide When BIOS performs the Power On Self Test it writes checkpoint codes to I O port 0080h If the computer cannot complete the boot process a diagnost...

Страница 102: ...ment for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassi...

Страница 103: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...

Страница 104: ...at werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummer...

Страница 105: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...

Страница 106: ...orrientes del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de...

Страница 107: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...

Страница 108: ...troomkabels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipm...

Страница 109: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...

Страница 110: ...acceso a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L...

Страница 111: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...

Страница 112: ...rikant aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection...

Страница 113: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...

Страница 114: ...tung Advertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectri...

Страница 115: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...

Страница 116: ...nationale elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled...

Страница 117: ...e recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...

Страница 118: ...los destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs so...

Страница 119: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSE Supermicro Supermicro UL CSA UL CSA Supermicro U...

Страница 120: ...iqu sur le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el prod...

Страница 121: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...

Страница 122: ...boot the system The UEFI offers a clean hands off control to a computer system at bootup C 2 Recovering the UEFI BIOS Image A UEFI BIOS flash chip consists of a recovery BIOS block and a main BIOS bl...

Страница 123: ...ROM file if the media size becomes too large because it contains too many folders and files To perform UEFI BIOS recovery using a USB attached device follow the instructions below 1 Using a different...

Страница 124: ...dures below 4 When the screen as shown above displays use the arrow keys to select the item Proceed with flash update and press the Enter key You will see the BIOS recovery progress as shown in the sc...

Страница 125: ...to enter the BIOS Setup utility From the top of the tool bar select Boot to enter the submenu From the submenu list select Boot Option 1 as shown below Then set Boot Option 1 to UEFI AP UEFI Built in...

Страница 126: ...o not interrupt this process until the BIOS flashing is complete 10 Press Del continuously to enter the BIOS Setup utility 11 Press F3 to load the default settings 12 After loading the default setting...

Страница 127: ...TC Wakeup Memory Supports up to 256GB of ECC RDIMM or 512GB of ECC LRDIMM DDR4 memory Operating speed up to 2133MHz for 1019D FRN5TP 1019D 12C FRN5TP and 1019D 14C FRN5TP Operating speed up to 2400MHz...

Страница 128: ...ance Electromagnetic Emissions FCC Class A EN 55032 Class A EN 61000 3 2 3 3 CISPR 32 Class A Electromagnetic Immunity EN 55024 CISPR 24 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4...

Отзывы: