background image

S

UPER

S

ERVER

®

 

 

1018R-WC0R

USER’S MANUAL

 

 

1.0a

Содержание SUPERSERVER 1018R-WC0R

Страница 1: ...SUPERSERVER 1018R WC0R USER S MANUAL 1 0a ...

Страница 2: ...erms of said license IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN PARTICULAR SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE SOFTWARE OR DATA STORED OR USED WITH THE PRODUCT INCLUDING THE COSTS OF REPA...

Страница 3: ...g uring the motherboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC116AC R706WB server chassis You should follow the procedures given in this chapter when installing removing or reconfiguring drives and when replacing system power supply units and cooling fans Chapter 7 BIOS The BIOS chapter includes an introduction to BIOS and provides detailed informa t...

Страница 4: ...ew 3 1 3 2 Control Panel Buttons 3 1 vii SUPERSERVER 1018R WC0R User s Manual Power 3 1 UID 3 2 3 3 Control Panel LEDs 3 2 Universal Information LED 3 2 NIC1 3 3 NIC2 3 3 HDD 3 3 Power 3 3 3 4 Hard Drive Carrier LEDs 3 4 Hard Drives 3 4 Chapter 4 Standardized Warning Statements for AC Systems 4 1 About Standardized Warning Statements 4 1 Warning Definition 4 1 Installation Instructions 4 4 Circuit...

Страница 5: ... Setup 6 1 Static Sensitive Devices 6 1 Precautions 6 1 Unpacking 6 1 6 2 Control Panel 6 2 6 3 Removing the Chassis Cover 6 2 6 4 System Fans 6 3 System Fan Failure 6 3 Checking the Airflow 6 5 6 5 Drive Bay Installation Removal 6 5 Accessing the Drive Bays 6 5 Hard Drive Installation 6 6 6 6 Power Supply 6 8 Power Supply Failure 6 8 Chapter 7 BIOS 7 1 Introduction 7 1 7 2 Main Setup 7 2 7 3 Adva...

Страница 6: ...4 cm PWM fans FAN 0101L4 One air shroud MCP 310 19002 0N SATA Accessories One SAS SATA backplane BPN SAS3 116A Ten drive carriers MCP 220 00047 0B Two riser cards RSC R1UW 2E16 O P RSC R1UW E8R O P Note For your system to work properly please follow the links below to download all necessary drivers utilities and the user s manual for your server Supermicro product manuals http www supermicro com s...

Страница 7: ...rt two USB 3 0 ports two USB 2 0 ports two gigabit Ethernet ports and one dedicated IPMI port A UID Unit Identifier button and LED are also included beside the VGA port 1 3 Server Chassis Features The SC116AC R706WB is Supermicro s third generation 1U chassis The following is a general outline of the main features of the SC116AC R706WB chassis System Power The SC116AC R706WB features a 750W power ...

Страница 8: ...ermicro nl Customer Support Web Site www supermicro nl Asia Pacific Address Super Micro Computer Inc 3F No 150 Jian 1st Rd Zhonghe Dist New Taipei City 235 Taiwan R O C Tel 886 2 8226 3990 Fax 886 2 8226 3992 Email support supermicro com tw Web Site www supermicro com tw SPI LAN3 RGRMII Debug Card FRONT PANEL SYSTEM POWER CTRL FAN SPEED PCI E X1 G2 USB 2 0 P13 USB2 0 PCH 6 0 Gb S USB 2 0 LPC USB 1...

Страница 9: ...1 6 SUPERSERVER 1018R WC0R User s Manual Notes ...

Страница 10: ... a suitable location for the rack unit that will hold the SuperServer 1018R WC0R It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated You will also need it placed near a grounded power outlet Read the Rack and Server Precautions in the next section 2 3 Preparing for Setup The box the SuperServer 101...

Страница 11: ... installed in a closed or multi unit rack assembly the ambient operating tempera ture of the rack environment may be greater than the ambient temperature of the room Therefore consideration should be given to installing the equipment in an environment compatible with the manufacturer s maximum rated ambient tempera ture Tmra Reduced Airflow Equipment should be mounted into a rack so that the amoun...

Страница 12: ...ions of the Rack Rails Inner Rails Inner rails are pre installed on the chassis Inner Rail Extensions Figure 2 2 Identifying the Sections of the Rack Rails right side rail shown Inner Rail Extension The SC116 chassis includes a set of inner rails in two sections inner rails and inner rail extensions The inner rails are pre attached and do not interfere with normal use of the chassis if you decide ...

Страница 13: ... bracket to the rear side of the outer rail with three M5 screws 4 Repeat steps 1 4 for the left outer rail Secure to the Front of the Rack Secure to the Rear of the Rack Figure 2 3 Assembling the Outer Rails Attach Outer Rails together Figure 2 4 Installing the Outer Rails to the Server Rack 1 2 1 3 1 3 Stability hazard The rack stabilizing mechanism must be in place or the rack must be bolted to...

Страница 14: ...ng tabs click into position 4 Optional Insert and tighten the thumbscrews that hold the front of the server to the rack Installing the Chassis into a Telco rack To install the chassis into a Telco or post style rack use two L shaped brackets on either side of the chassis four total 1 First determine how far follow the server will extend out the front of the rack Larger chassis should be positioned...

Страница 15: ...2 10 SUPERSERVER 1018R WC0R User s Manual Figure 2 6 Installing the Chassis into a Telco Rack Note figures are for illustrative purposes only Always install servers to the bottom of a rack first ...

Страница 16: ...priate responses that need to be taken 3 2 Control Panel Buttons There are two buttons located on the front of the chassis a power on off button and a UID button Figure 3 1 Control Panel Buttons and LEDs Power The main power switch is used to apply or remove power from the power supply to the server system Turning off system power with this button removes the main power but keeps standby power sup...

Страница 17: ...hich may be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm Check the routing of the cables and make sure all fans are present and operating normally You should also check to make sure that the chassis covers are installed Finally verify that the heatsinks are installed properly see Chapter 5 This LED will remain flashing or on as long as the i...

Страница 18: ...ive carrier has two LEDs Blue When illuminated this blue LED on the front of the hard drive carrier indicates drive activity A connection to the backplane enables this LED to blink on and off when that particular drive is being accessed Red The red LED indicates a drive failure If one of the drives fail you should be notified by your system management software ...

Страница 19: ... configuring components in the Supermicro chassis These warnings may also be found on our web site at http www supermicro com about policies safety_information cfm Warning This warning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preve...

Страница 20: ... couramment utilisées pour éviter les accidents Pour prendre connaissance des traductions des avertissements figurant dans les consignes de sécurité traduites qui accompagnent cet appareil référez vous au numéro de l instruction situé à la fin de chaque avertissement CONSERVEZ CES INFORMATIONS 안전을 위한 주의사항 경고 이 경고 기호는 위험이 있음을 알려 줍니다 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다 모든 장비에 대한 작업을 수행하기 전에 전기회로와 관련된 ...

Страница 21: ...em op de voedingsbron aansluit サーキッ ト ブレーカー この製品は 短絡 過電流 保護装置がある建物での設置を前提としています 保護装置の定格が250 V 20 Aを超えないこ とを確認下さい Warnung Dieses Produkt ist darauf angewiesen dass im Gebäude ein Kurzschluss bzw Überstromschutz installiert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A beträgt Advertencia Este equipo utiliza el sistema de protección contra cortocircuitos o ...

Страница 22: ...r of het beveiligde aparaat niet groter gedimensioneerd is dan 220V 20A Advertencia El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le système doit être débranché de toutes les sources de puissance ainsi qu...

Страница 23: ...אזהרה רש בלבד מוסמך צוות את להחליף להתקין אי הציוד עבור שירות לתת או הציוד والمدربيه و لتزكيب استبدال أو خدمة الجهاس هذا يسمح أن يجب فقط المؤهليه للمىظفيه 경고 훈련을 받고 공인된 기술자만이 이 장비의 설치 교체 또는 서비스를 수행할 수 있습니다 Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd vervangen of hersteld door geschoold en gekwalificeerd personeel Warnung Diese Einheit ist zur Installation in Bereichen mit beschrän...

Страница 24: ...نتركُبها مناطق محظورة تم انىص َمكن ً إن ىل منطقت محظورة فقط استخذاو خالل من خاصت أداة أو ٌ أ نال أخري وسُهت مألما ومفتاح قفم 경고 이 장치는 접근이 제한된 구역에 설치하도록 되어있습니다 특수도구 잠금 장치 및 키 또는 기타 보안 수단을 통해서만 접근 제한 구역에 들어갈 수 있습니다 Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een beperkte toegang Toegang tot dergelijke gebieden kunnen alleen verkregen worden door gebruik te maken van speciaa...

Страница 25: ...o el sistema está en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le système est en fonctionnement des tensions électriques circulent sur le fond de panier Prendre des précautions lors de la maintenance Warning Hazardous voltage or energy is present on the backplane when the system is operating Use caution when servicing Redundant Power ...

Страница 26: ...חשמל לחוקי תואמת להיות חייבת הציוד المعدات تركيب الكهربائية لل يمتثل أن يجب قىاويه والىطىية المحلية المتعلقة بالكهرباء 경고 시스템이 동작 중일 때 후면판 Backplane 에는 위험한 전압이나 에너지가 발생 합니다 서비스 작업 시 주의하십시오 Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is geboden tijdens het onderhoud האחורי בפנל מתח אז הרה במהלך להיזהר יש המערכת תפעול...

Страница 27: ...ncia Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis Mandtenga los dedos los destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez le bloc ventilateur du châssis Prenez garde à ce que doigts tournevis et autres objets soient éloignés du ...

Страница 28: ... tienen UL o CSA se muestra en el código de otros dispositivos eléctricos que los productos designados por Supermicro solamente 電源コードとACアダプター 製品を設置する場合 提供または指定された接続ケーブル 電源コードとACアダプター を使用下さい 他のケーブルやアダプタを使用すると故障や火災の原因になるこ とがあ り ます 電気用品安全法は ULまたはCSA認定のケーブル UL CSEマークがコードに表 記 を Supermicroが指定する製品以外に使用するこ とを禁止しています ומתא חשמליים מ י AC אזהרה ומתאמים ספקים בכבלים להשתמש יש המוצר את מתקינים כאשר AC אשר או ל...

Страница 29: ...4 20 SUPERSERVER 1018R WC0R User s Manual Notes ...

Страница 30: ...ne hand under the center of the board to support it when handling The following measures are generally sufficient to protect your equipment from electric static discharge Precautions Use a grounded wrist strap designed to prevent ESD Touch a grounded metal object before removing boards from antistatic bags Handle a board by its edges only do not touch its components peripheral chips memory modules...

Страница 31: ...power supply connector J24 for connection to the ATX power supply In addition there is a 8 pin 12V processor power con nector JPWR1 that must be connected to your power supply See Section 5 9 for power connector pin definitions Connecting the Control Panel JF1 contains header pins for various front control panel connectors See Figure 5 1 for the pin locations of the various front control panel but...

Страница 32: ...se contact your retailer immediately Refer to the Supermicro web site for updates on CPU support OPEN1st WARNING OPEN1st WARNING Press down on the lever labeled Close 1st Pull lever away from the socket Gently push down to pop the load plate open 3 With the lever labeled Close 1st fully retracted gently push down on the Open 1st lever to open the load plate Lift the load plate to open it completel...

Страница 33: ...Screw in two diagonal screws i e the 1 and the 2 screws until just snug to avoid possible damage to the CPU do not over tighten the screws 4 Add the two remaining screws then fully tighten all four screws Figure 5 3 Installing the Heatsink Note be aware that the heatsink for CPU1 must be installed in the correct orien tation the air tunnel must be on the right side when viewed from the front of th...

Страница 34: ...ace in the slot Repeat for all modules 4 Press the release tabs to the locked positions to secure the DIMM module into the slot Caution Exercise extreme care when installing or removing DIMM modules to prevent any possible damage 5 5 Installing Memory Figure 5 4 DIMM Installation DIMM Module Population Table Follow the table below when installing memory Socket Key Populating RDIMM LRDIMM DDR4 Memo...

Страница 35: ...B 256 MB 3 51 PCI Enumeration Area 2 if needed Aligned on 256 MB boundary 512 MB 3 01 TSEG 1 MB 2 84 Memory available to OS and other applications 2 84 5 6 Adding PCIe Add On Cards The 1018R WC0R can accommodate two full height full length PCIe 3 0 x16 and one low profile half length PCIe 3 0 x8 add on expansion cards installed to the riser cards included in the system Installing an Add on Card 1 ...

Страница 36: ...F Quick Reference Jumper Description Default JBR1 BIOS Recovery Pins 1 2 Normal JBRSET1 FIQ Request Pins 1 2 Normal JBT1 CMOS Clear See Section 5 9 JI2 C1 JI2 C2 SMB to PCI E Slots Pins 2 3 Disabled JPB1 BMC Enable Disable Pins 1 2 Enabled JPG1 VGA Enable Pins 1 2 Enabled JPL1 LAN Enable Pins 1 2 Enabled JWD1 Watch Dog Enable Pins 1 2 Reset Connector Description COM1 COM2 COM1 Port COM2 Header FAN...

Страница 37: ...er supply and serverboard Power Connectors A 24 pin main power supply connector J24 and an 8 pin CPU power con nector JPWR1 must be connected to the power supply These power connectors meet the SSI EPS 12V specification See the table on the right for pin definitions NC No Connection Overheat OH Fan Fail PWR Fail UID LED Connect an LED cable to pins 7 and 8 of Front Control Panel to use the Overhea...

Страница 38: ...Four Universal Serial Bus ports USB 0 1 USB 2 3 are located on the I O backpanel In addition three USB headers USB 4 5 6 7 9 10 two USB 3 0 headers USB 11 12 and a Tpe A header USB 8 are provided for front accessible USB connections cables are not included See the tables on the right for pin definitions FP USB Pin Definitions USB 4 8 6 Pin Definition USB 5 9 Pin Definition 1 5V 1 5V 2 PO 2 PO 3 PO...

Страница 39: ...vide 5V power to a solid state DOM storage device connected to one of the SATA ports See the table on the right for pin definitions DOM PWR Pin Definitions Pin Definition 1 5V 2 Ground 3 Ground Power Supply SMBus I2 C Header The power System Management Bus header at JPI2 C1 is used to monitor the status of the power supply fan and system temperature See the table on the right for pin definitions T...

Страница 40: ...on the system Note Do not use the PW_ON connector to clear CMOS LAN Enable Disable Use JPL1 and JPL2 to enable disable LAN ports 1 2 See the table on the right for jumper settings The default setting is Enabled LAN1 2 Enable Jumper Settings Jumper Setting Definition Pins 1 2 Enabled Pins 2 3 Disabled VGA Enable Disable JPG1 allows you to enable or disable the VGA port The default position is on pi...

Страница 41: ...reen Solid Amber Solid 100 Mbps 1 Gbps Activity Right Yellow Blink ing Active LAN 1 LAN 2 Link LED Left LED State LED Color Definition Off 10 Mbps or No Connection Green 100 Mbps Amber 1 Gbps Watch Dog Enable Disable Jumper JWD controls the Watch Dog function Watch Dog is a system moni tor that can reboot the system when a software application hangs Jumping pins 1 2 will cause WD to reset the sys ...

Страница 42: ...the drivers and utilities it contains You may also use a utility to extract the ISO file if preferred Another option is to go to the Supermicro Website at http www supermicro com products Find the product page for your serverboard here where you may down load individual drivers and utilities After creating a CD DVD with the ISO files insert the disk into the CD DVD drive on your system and the dis...

Страница 43: ...tors system health information such as CPU temperature system voltages system power consumption fan speed and provides alerts via email or Simple Network Management Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Man agement Server SSM Server you can remotely control power on off and r...

Страница 44: ...5 28 SUPERSERVER 1018R WC0R User s Manual Notes ...

Страница 45: ...em very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded metal object before removing any board from its antistatic bag Handle a board by its edges only do not touch its components peripheral chips memory modules or gold contacts When handling chips or mod...

Страница 46: ...the JF1 connector on the motherboard to provide you with system status indications A ribbon cable has bundled these wires together to simplify the connection Connect the cable from JF1 on the motherboard to the Control Panel PCB printed circuit board Make sure the red wire plugs into pin 1 on both connectors Pull all excess cabling out of the airflow path The LEDs inform you of system status See C...

Страница 47: ...s the inside of the chassis or power down the system to install or replace hard drives Refer to the figure below for the drive bay configuration on the 1018R WC0R Replacing a System Fan 1 Open the chassis while the system is running to determine which fan has failed Never run the server for an extended period of time with the chassis open 2 Turn off the power to the system and unplug the power cor...

Страница 48: ...on is on the right side When the carrier reaches the rear of the bay the release handle will retract 5 Push the handle in until it clicks into its locked position Figure 6 5 Installing a Drive into a Carrier Removing a Hard Drive 1 To remove a carrier push the release button located beside the drive LEDs 2 Swing the handle fully out and use it to pull the unit straight out Note Your operating syst...

Страница 49: ...edundant power supply which allows the server to continue running when one power supply has been removed Replacement units can be ordered directly from Supermicro Replacing the Power Supply 1 Check the LEDs on the power supplies to determine which module has failed 2 Unplug the power cord from the failed module 3 Push the release tab on the back of the power supply as illustrated then pull the pow...

Страница 50: ... configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in the left frame it is highlighted in white Often a text message will accompany it Note the AMI BIOS has default text messages built in Supermicro retains the option to include omit or change any of these text mess...

Страница 51: ...the Setup Utility Normally the only visible Power On Self Test POST routine is the memory test As the memory is being tested press the Delete key to enter the main menu of the AMI BIOS setup utility From the main menu you can access the other setup screens An AMI BIOS identification string is displayed at the left bottom corner of the screen below the copyright message Warning Do not upgrade the B...

Страница 52: ... of the host adaptors will not capture Interrupt 19 immediately and allow the drives attached to these adaptors to function as bootable devices at bootup The options are Immediate and Postponed Re try Boot When EFI Boot is selected the system BIOS will automatically reboot the system from an EFI boot device after its initial boot failure Select Legacy Boot to allow the BIOS to automatically reboot...

Страница 53: ...state P0 lasts less than two seconds The options are Traditional and Power Optimized Execute Disable Bit Available if supported by the OS the CPU Set to Enabled for Execute Disable Bit support which will allow the processor to designate areas in the system memory where an application code can execute and where it cannot thus preventing a worm or a virus from flooding illegal codes to over whelm th...

Страница 54: ...gh the DMAR ACPI Tables This feature offers fully protected I O resource sharing across the Intel platforms providing the user with greater reliability security and availability in networking and data sharing The settings are Enable and Disable Advanced Power Management Configuration Power Technology Select Energy Efficient to support power saving mode Select Custom to custom ize system power sett...

Страница 55: ...r with P0 being the state with the highest frequency clock speed and power consumption and P1 a step lower in performance than P0 with its frequency and voltage scaled back a notch The options are Between P1 P0 and Below P1 Short Duration Power Limit Enable Select Enable to support Short Duration Power Limit Power Limit 2 The options are Enable and Disable Short Duration Power Limit This item disp...

Страница 56: ...nable Relaxed Ordering Select Enable to enable Relaxed Ordering support which will allow certain trans actions to violate the strict ordering rules of PCI and to be completed prior to other transactions that have already been enqueued The options are Disable and Enable Intel VT for Directed I O VT d Intel VT for Direct I O VT d Intel VT for Directed I O VT d Select Enable to use Intel Virtualizati...

Страница 57: ...ble and Disable Data Scrambling Select Enabled to enable data scrambling to enhance system performance and data integrity The options are Auto Disabled and Enabled Enable ADR Select Enabled for ADR Automatic Diagnostic Repository support to enhance memory performance The options are Enabled and Disabled DRAM RAPL Running Average Power Limit Baseline Use this feature to set the run time power limit...

Страница 58: ...he error is corrected and sent to the requestor the original source Memory is corrected as well Select Enable to use Demand Scrubbing for ECC memory correction The options are Enable and Disable Device Tagging Select Enable to support device tagging The options are Disable and Enable South Bridge The following South Bridge information will display USB Configuration USB Module Version USB Devices L...

Страница 59: ...wer Management When this item is set to Enabled the SATA AHCI controller manages the power usage of the SATA link The controller will put the link in a low power mode during extended periods of I O inactivity and will return the link to an active state when I O activity resumes The options are Enabled and Disabled SATA Port 0 Port 5 This item displays the information detected on the installed SATA...

Страница 60: ...tate drive or a Hard Disk Drive The options are Hard Disk Drive and Solid State Drive sSATA Configuration When this submenu is selected the AMI BIOS automatically detects the presence of the SATA devices that are supported by the SCU controller and displays the following items sSATA Controller This item enables or disables the onboard SATA controller supported by the Intel SCU chip The options are...

Страница 61: ...T initialization to the device The options are Enabled and Disabled Port 0 Port 3 sSATA Device Type Use this item to specify if the sSATA port specified by the user should be con nected to a Solid State drive or a Hard Disk Drive The options are Hard Disk Drive and Solid State Drive If the item above Configure sSATA as is set to IDE the following items will display sSATA Port 0 Port 3 This item in...

Страница 62: ...4 Bytes 2048 Bytes and 4096 Bytes ASPM Support Use this item to set the Active State Power Management ASPM level for a PCI E device Select Auto for the system BIOS to automatically set the ASPM level based on the system configuration Select Disabled to disable ASPM support The options are Disabled and Auto Warning Enabling ASPM support may cause some PCI E devices to fail MMIOHBase Use this item t...

Страница 63: ...T100 to use the ASCII Character set Select VT100 to add color and function key support Select ANSI to use the Extended ASCII Char acter Set Select VT UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes The options are ANSI VT100 VT100 and VT UTF8 Bits Per second Use this item to set the transmission speed for a serial port used in Console Redirection Make sure that the same ...

Страница 64: ...es The options are ANSI VT100 VT100 and VT UTF8 Bits Per second Use this feature to set the transmission speed for a serial port used in Console Redirection Make sure that the same speed is used in the host computer and the client computer A lower transmission speed may be required for long and busy lines The options are 9600 19200 38400 57600 and 115200 bits per second Data Bits Use this feature ...

Страница 65: ...0 to add color and function key support Select ANSI to use the extended ASCII character set Select VT UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes The options are ANSI VT100 VT100 and VT UTF8 Bits Per Second This item sets the transmission speed for a serial port used in Console Redirec tion Make sure that the same speed is used in the host computer and the client com...

Страница 66: ...elect Enabled to enable SMBIOS System Management BIOS Event Logging during system boot The options are Enabled and Disabled Runtime Error Logging Support Select Enabled to support Runtime Error Logging The options are Enable and Dis able If this item is set to Enable the following item will be available for configuration Memory Corrected Error Enabling Available when the item above Runtime Error L...

Страница 67: ...iple event counter wait before generating a new event log Enter a number between 0 to 99 The default setting is 60 Note Please reboot the system for the changes to take effect View System Event Log This item allows the user to view the event in the system event log Select this item and press Enter to view the status of an event in the log Date Time Sensor Type 7 5 IPMI Use this feature to configur...

Страница 68: ...e IP address for this computer If Static is selected you will need to know the IP address of this computer and enter it to the system manually in the field If DHCP is selected the BIOS will search for a DHCP Dynamic Host Configuration Protocol server in the network that is attached to and request the next available IP address for this computer The options are DHCP and Static The following items ar...

Страница 69: ...Boot Settings Use this feature to configure Boot Settings Setup Prompt Timeout Use this item to indicate the length of time the number of seconds for the BIOS to wait before rebooting the system when the setup activation key is pressed Enter the value of 65535 0xFFFF for the BIOS to wait indefinitely The default setting is 1 Boot Mode Select Use this item to select the type of device that the syst...

Страница 70: ...to delete 7 8 Save Exit Select the Save Exit tab from the BIOS setup screen to configure the settings below Discard Changes and Exit Select this option to quit the BIOS setup without making any permanent changes to the system configuration and reboot the computer Select Discard Changes and Exit from the Exit menu and press Enter Save Changes and Reset When you have completed the system configurati...

Страница 71: ... for future use Restore User Defaults To set this feature select Restore User Defaults from the Exit menu and press En ter Use this feature to retrieve user defined settings that were saved previously Boot Override This feature allows the user to override the Boot Option Priorities sequence in the Boot menu and immediately boot the system with another device specified by the user This is a one tim...

Страница 72: ...f a fatal error occurs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list correspond to the number of beeps for the corresponding error BIOS Error Beep Codes Beep Code LED Error Message Description 1 beep Refresh Circuits have been reset Ready to power up 5 short bee...

Страница 73: ...A 2 SUPERSERVER 1018R WC0R User s Manual Notes ...

Страница 74: ... SPI Flash ROM Memory Capacity Eight DIMM sockets supporting up 1 TB of ECC 3DS LRDIMM Load Reduced DIMMs 512 GB of ECC LRDIMM or up to 256 GB of ECC RDIMM Registered DIMM DDR4 2400 2133 1600 1333 memory Note see Section 5 5 for details Drive Bays Ten hot swap drive bays to house 2 5 SATA or SAS drives Motherboard X10SRW F WIO form factor Dimensions 8 15 x 13 05 in 207 x 331 5 mm Chassis SC116AC R...

Страница 75: ...º to 60º C 40º to 140º F Operating Relative Humidity 8 to 90 non condensing Non operating Relative Humidity 5 to 95 non condensing Regulatory Compliance Electromagnetic Emissions FCC Class A EN 55022 Class A EN 61000 3 2 3 3 CISPR 22 Class A Electromagnetic Immunity EN 55024 CISPR 24 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Safety CSA EN IEC UL 60...

Страница 76: ...erform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell such products for use in such ultra hazardous applications it does so entirely at its own risk Furthermore buyer agrees to fully indemnify defend and hold Supermicro harmless for and against any and all cl...

Отзывы: