5-8
SUPERSERVER
1028R-WTR(T) USER'S MANUAL
Installing and Removing a Passive CPU Heatsink
1. Do not apply any thermal grease to the heatsink or the CPU die; the required
amount has already been applied.
2. Place the heatsink on top of the CPU so that the four mounting holes are
aligned with those on the serverboard and the heatsink bracket underneath.
3. Screw in two diagonal screws (i.e., the #1 and the #2 screws) until just snug
(to avoid possible damage to the CPU, do not over-tighten the screws.)
4. Add the two remaining screws then fully tighten all four screws.
Removing the Heatsink
Caution:
Removing the CPU or the heatsink is not recommended. However, if
necessary, please follow the instructions below.
1. Unscrew the heatsink screws from the serverboard in the sequence shown.
2. Gently wriggle the heatsink to loosen it from the CPU (do not use excessive
force). Once the CPU is loose, remove the it from the CPU socket.
3. Clean the surface of the CPU and the heatsink to remove the used thermal
grease. Reapply the proper amount of thermal grease then re-install the CPU
and the heatsink.
Figure 5-3. Installing the Heatsink
Loosen screws
in sequence as
shown.
Screw#2
Screw#1
Screw#3
Screw#4
Содержание SUPERO SUPERSERVER 1028R-WTR Series
Страница 1: ...SUPERSERVER 1028R WTR T SUPER USER S MANUAL Revision 1 0...
Страница 5: ...Notes Preface v...
Страница 10: ...Notes SUPERSERVER 1028R WTR T USER S MANUAL x...
Страница 59: ...Chapter 5 Advanced Serverboard Setup 5 9 Figure 5 3 Heatsink Placement...
Страница 88: ...6 8 SUPERSERVER 1028R WTR T USER S MANUAL Figure 6 5 Removing Replacing the Power Supply Release Tab...
Страница 120: ...7 32 SUPERSERVER 1028R WTR T USER S MANUAL Notes...
Страница 122: ...A 2 SUPERSERVER 1028R WTR T USER S MANUAL Notes...
Страница 125: ...B 3 Appendix B System Specifications Notes...