Chapter 7: BIOS
7-9
Throttling - Closed Loop/Throttling - Open Loop
Throttling improves CPU's reliability and power effi ciency via automatic voltage
control during idle states. The options are
Disabled
and Enabled.
If Enabled, the following items will appear:
Hysteresis Temperature (Closed Loop Only)
Temperature Hysteresis is the temperature lag (in degrees Celsius) after the
preset DIMM temperature threshold is reached before Closed Loop Throt-
tling begins. The options are Disabled,
1.5
o
C
, 3.0
o
C, and 6.0
o
C.
Guardband Temperature (Closed Loop Only)
This is the temperature applied to the DIMM temperature threshold. Each
step is in 0.5oC increment. The default is
[006]
.
Inlet Temperature
This is the temperature detected at the chassis inlet. Each step is in 0.5
o
C
increment. The default is
[070]
.
Temperature Rise
This is the temperature rise to the DIMM thermal zone. Each step is in
0.5
o
C increment. The default is
[020]
. Press "+" or "-" on your keyboard to
change this value.
Air Flow
This is the air fl ow speed to the DIMM modules. Each step is one mm/sec.
The default is
[1500]
.
Altitude
This feature defi nes how many meters above or below sea level the system
is located. The options are
Sea Level or Below,
1~300, 301~600, 601~900,
901~1200, 1201~1500, 1501~1800, 1801~2100, 2101~2400, 2401~2700,
2701~3000.
DIMM Pitch
This is the physical space between each DIMM module. Each step is in
1/1000 of an inch. The default is
[400]
.
North Bridge Confi guration
This feature allows the user to confi gure the settings for the North Bridge chip.
Содержание Supero 6016T-6F
Страница 1: ... SUPERSERVER 6016T 6F SUPER USER S MANUAL 1 0a ...
Страница 5: ...Notes Preface v ...
Страница 28: ...3 4 SUPERSERVER 6016T 6F User s Manual Notes ...
Страница 48: ...4 20 SUPERSERVER 6016T 6F User s Manual Notes ...
Страница 74: ...5 26 SUPERSERVER 6016T 6F User s Manual Notes ...
Страница 84: ...6 10 SUPERSERVER 6016T 6F User s Manual Notes ...
Страница 116: ...A 2 SUPERSERVER 6016T 6F User s Manual Notes ...