Chapter 2: Server Installation
2-5
Installing the Outer Rails
Begin by measuring the distance from the front rail to the rear rail of the rack. Attach
a short bracket to the front side of the right outer rail and a long bracket to the rear
side of the right outer rail. Adjust both the short and long brackets to the proper
distance so that the rail can fi t snugly into the rack. Secure the short bracket to the
front side of the outer rail with two screws and the long bracket to the rear side of
the outer rail with three screws. Repeat these steps for the left outer rail.
Locking Tabs:
Both chassis rails have a locking tab, which serves two functions.
The fi rst is to lock the server into place when installed and pushed fully into the
rack, which is its normal position. Secondly, these tabs also lock the server in place
when fully extended from the rack. This prevents the server from coming completely
out of the rack when you pull it out for servicing.
Figure 2-2. Installing the Rack Rails
Warning!
To prevent bodily injury when mounting or servicing this unit in a
rack, you must take special precautions to ensure that the system remains
stable. The following guidelines are provided to ensure your safety:
•
This unit should be mounted at the bottom of the rack if it is the only unit in
the rack.
•
When mounting this unit in a partially fi lled rack, load the rack from the bottom
to the top with the heaviest component at the bottom of the rack.
•
If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the unit in the rack.
Содержание Supero 6016T-6F
Страница 1: ... SUPERSERVER 6016T 6F SUPER USER S MANUAL 1 0a ...
Страница 5: ...Notes Preface v ...
Страница 28: ...3 4 SUPERSERVER 6016T 6F User s Manual Notes ...
Страница 48: ...4 20 SUPERSERVER 6016T 6F User s Manual Notes ...
Страница 74: ...5 26 SUPERSERVER 6016T 6F User s Manual Notes ...
Страница 84: ...6 10 SUPERSERVER 6016T 6F User s Manual Notes ...
Страница 116: ...A 2 SUPERSERVER 6016T 6F User s Manual Notes ...