Chapter 2: Server Installation
2-7
2-6 Power-up/Power-down
Sequence
The K1048-RT system's power up/power-down sequences and indications are
shown below.
Powering-up the System
Timing
Indications
Plug the system into power source
PSU LED will light
Wait 30 Seconds
None
30 Seconds after power cord is plugged in
BMC ready/ onboard LED fl ashes (seen through
air vent(chassis/ rear) Indicating the board
management has booted successfully
Push-on Power button
Button LED turns green
Drives spin up, switch initializes *
Depending on environmental temperature Fans may
not spin-up like a typical server power-up
~15-30 seconds after power button is pressed,
Ethernet drives are available for DHCP address
assignment on the redundant networks
Internal link LEDs are lit solid on the mainboard
PHY indicators
*Initial boot/spin-up may be silent.
Powering Off the System
Timing
Indications
Hold power button for 6 seconds, then release
None
System shutdown will occur within seven seconds
Power button LED will go dark
BMC remains powered on accessible until system
is unplugged
Содержание K1048-RT