Chapter 2: Server Installation
2-5
CAUTION
KEEP
SHUTTLE
LOCKED
REPON 1U SLIDE USER MANUAL
IMPORTANT NOTES: :
1. DO NOT SWAP RIGHT HAND INNER WITH LEFT HAND, VISE VERSA.
2. MOUNT INNER MEMBER TO CHASSIS WITH CARE, DO NOT WAVE OR DROP IT..
PULL INNER MEMBER OUT
PRESS THE FRONT
TRIGGER DOWN TO
PULL INNER OUT
FURTHER
PULL THE INNER ALL
THE WAY OUT TO
REMOVE THE INNER
INNER
MEMBER
STEP1
STEP2
STEP3
STEP4
ALIGN THE INNER TO
THE STAND OFF ON
SIDE OF CHASSIS
MAKE SURE THE STAND OFF DROP THROUGH THE KEY SLOT,
AND PUSH THE INNER FORWARD SO THAT THE LOCKING TAB
WILL LEAN AGAINST THE STAND OFF
PRESS AND ROTATE THE LATCH TO PUSH THE
INTERMEDIATE ALL THE WAY BACK
INTERMEDIATE
MEMBER
PUSH THE YELLOW PIECE BACKWARD
AND PULL THE BRACKET TO PASS THE
SLOT
PULL YELLOW PIECE
FORWARD TO
SECURE THE
BRACKET
PUSH THE REAR
BACKET BACK AND
REPEAT THE SAME
STEPS
PRESS BOTH FRONT AND REAR TRIGGER DOWN TO PUSH THE CHASSIS
FURTHER INTO THE CABINET TILL IT REACHES CLOSED POSITION
STEP5
INSTALLATION IS
COMPLETE!!
STEP6
BEARING CARRIER SHALL
ALWAYS BE IN THE FRONT
POSITION.
WHEN YOU SEE CAUTION
SIGN, PLEASE PUSH THE
CARRIER TO THE FRONT
LOCKING POSITION.
FASTEN THE THUMB SCREW ON THE EAR PLATE
TO SECURE THE CHASSIS TO THE RACK
UNINSTALL THE BRACKET, PLEASE FOLLOW THE
STEPS BELOW.
M4 SCREW
( OPTIONAL )
PUSH YELLOW
LOCK PIECE BACK
PRY SPRING
HOOKS OPEN
PUSH BRACKET BACK
TILL HOOKS OFF THE
CUTOUT
Figure 2-2. Installing the Rails to the Chassis
In order to install the rails onto the rack, refer to the illustration below.