K1048-RT Microserver User's Manual
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack
itself should be grounded. Particular attention should be given to power supply
connections other than the direct connections to the branch circuit (i.e. the use of
power strips, etc.).
2-5 Installing the System into a Rack
This section provides information on installing the chassis into a rack unit with the
rails provided. There are a variety of rack units on the market, which may mean
that the assembly procedure differs slightly. You should also refer to the installation
instructions that came with the rack unit you are using.
Note:
These rails will fi t a rack between 27" and 38" deep.
Warning:
Do not pick up the server with the front handles. They are
designed to pull the system from a rack only.
Stability Hazard:
The rack stabilizing mechanism must be in place, or the
rack must be bolted to the fl oor before you slide the unit out for servicing. Failure
to stabilize the rack can cause the rack to tip over.
Figure 2-1. Identifying the Sections of the Rack Rails
Inner Rail--
pre-attached to the
chassis
Front and Rear
Brackets--attach
to the rack