background image

®

   

S

UPER

USER'S MANUAL

Revision 1.1a

FatTwin

F617H6-FTL+

F617H6-FTPTL+

Содержание FatTwin F617H6-FTL+

Страница 1: ...SUPER USER S MANUAL Revision 1 1a FatTwin F617H6 FTL F617H6 FTPTL...

Страница 2: ...of any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the lim...

Страница 3: ...4IS R1K62B chassis Chapter 2 Server Installation ThischapterdescribesthestepsnecessarytoinstalltheFatTwinF617H6 FTL FTPTL into a rack and check out the server configuration prior to powering up the sy...

Страница 4: ...low the procedures given in this chapter when installing removing or reconfiguring SATA or peripheral drives and when replacing system power supply units and cooling fans Chapter 7 BIOS The BIOS chapt...

Страница 5: ...v FatTwin F617H6 FTL FTPTL User s Manual Notes...

Страница 6: ...SATA Drive Power 1 5 Super I O 1 5 1 3 Server Chassis Features 1 5 System Power 1 5 SAS SATA Subsystem 1 5 I O Ports 1 5 Cooling System 1 6 Air Shrouds 1 6 Mounting Rails 1 6 1 4 Advanced Power Manage...

Страница 7: ...rd Setup 2 8 2 7 Checking the Drive Bay Setup 2 9 Chapter 3 System Interface 3 1 Overview 3 1 3 3 F414IS Front I O Control Panel 3 1 3 4 Control Panel LEDs 3 2 Chapter 4 Standardized Warning Statement...

Страница 8: ...n of Jumpers 5 23 5 9 Onboard Indicators 5 25 5 10 Serial ATA Connections 5 27 5 11 Installing Drivers 5 28 SuperDoctor III 5 29 5 12 Serverboard Battery 5 31 Chapter 6 Advanced Chassis Setup 6 1 Stat...

Страница 9: ...13 Replacing the Power Supply 6 18 Power Supply Replacement 6 19 Chapter 7 BIOS 7 1 Introduction 7 1 Starting BIOS Setup Utility 7 1 How To Change the Configuration Data 7 2 Starting the Setup Utilit...

Страница 10: ...x Notes FatTwin F617H6 FTL FTPTL User s Manual...

Страница 11: ...adapter boards BPN ADP F418L O P Power Cables Four 4 8pin to 2x2pin 50cm and 2 SATA power connectors 46cm and 16cm 18AWG power cables CBL PWEX 0511 01 Four 4 8 pin to 2 2x2 50 60 cm and 2 SATA 26 16 c...

Страница 12: ...or a block diagram of the chipset Processors The X9DRFF 7G 7TG supports single or dual Intel E5 2600 series processors in Socket R LGA 2011 sockets Please refer to the serverboard description pages on...

Страница 13: ...Note For IPMI Configuration Instructions please refer to the Embedded IPMI Configuration User s Guide available http www supermicro com support manuals Graphics Controller The X9DRFF 7G 7TG features...

Страница 14: ...phics controller Other Features Supported by the WPCM BMC Controller The WPCM450R supports the following features IPMI 2 0 Serial over LAN KVM over LAN LAN Alerting SNMP Trap Event Log X Bus parallel...

Страница 15: ...efficiency 94 Platinum certified redundant 1620 Watt power supplies In the unlikely event your power supply fails replacement is simple and can be accomplished without tools SAS SATA Subsystem The F4...

Страница 16: ...icro com to puchase the proper air shroud Mounting Rails The F414IS includes a set of rails and can be placed in a rack for secure storage and use To setup your rack follow the step by step instructio...

Страница 17: ...8 15 Gen3 x8 0 7 Gen2 x4 VGA CONN LAN RJ45 RJ45 PHY RTL8201F LAN X540 SAS2308 AT25321 6 3 1 5 3 1 5 3 1 5 3 1 5 3 1 5 6 3 1 5 I350 2 ports PCI Ex16x16 Proprietary SLOT PCI Ex16 Proprietary SLOT PCI E...

Страница 18: ...om Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support sup...

Страница 19: ...and lower nodes on the inner chassis wall This guide pin also acts as a stop when a node is fully installed If too much force is used when inserting a node this pin may break off Take care to slowly s...

Страница 20: ...1 10 FatTwin F617H6 FTL FTPTL User s Manual Notes...

Страница 21: ...any way If the server itself shows damage you should file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the FatTwin F617H6 FTL FTPTL...

Страница 22: ...rack installation stabilizers should be attached to the rack In multiple rack installations the racks should be coupled together Always make sure the rack is stable before extending a component from t...

Страница 23: ...i unit rack assembly the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room Therefore consideration should be given to installing the equipme...

Страница 24: ...rack only Stability Hazard The rack stabilizing mechanism must be in place or the rack must be bolted to the floor before you slide the unit out for servicing Failure to stabilize the rack can cause...

Страница 25: ...ing Screw Outer Rail Locking Tab Locking Tabs Each inner rail has a locking tab This tab locks the chassis into place when installed and pushed fully into the rack These tabs also lock the chassis in...

Страница 26: ...ont post of the rack Secure the front of the outer rail to the rack with two screws 3 Pull out the rear section of the outer rail adjusting the length until it fits within the posts of the rack 4 Alig...

Страница 27: ...ssis Installation Installing the Chassis into a Rack 1 Confirm that the rails are correctly installed on the rack 2 Align the bottom of the chassis with the bottom of the rails 3 Insert the chassis in...

Страница 28: ...e to allow proper airflow and prevent overheating Checking the Components and Setup 1 You may have one or two processors already installed into the serverboard Each processor needs its own heat sink S...

Страница 29: ...d out of the server In addition if you are using a front bezel make sure the bezel s filter is replaced periodically 2 Do not operate the server without drives or drive trays in the drive bays Use onl...

Страница 30: ...2 10 FatTwin F617H6 FTL FTPTL User s Manual Notes...

Страница 31: ...models include four control panels which control each of the systems This chapter explains the meanings of all LED indicators and the appropriate re sponse you may need to take Figure 3 2 F414IS Node...

Страница 32: ...be easily located in very large racks and server banks 3 4 Control Panel LEDs The four control panels are located on the front handle of the F414IS chassis Each control panel has two additional LEDs T...

Страница 33: ...Chapter 3 System Interface 3 3 NIC Indicates network activity on either LAN1 or LAN2 when flashing...

Страница 34: ...FatTwin F617H6 FTL FTPTL User s Manual 3 4 Notes...

Страница 35: ...nt for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Страница 36: ...considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar...

Страница 37: ...l kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard proc...

Страница 38: ...ie en des Systems an die Stromquelle die Installationsanweisungen lesen Advertencia Lea las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Attention Avant de branch...

Страница 39: ...erstromschutz installiert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt Advertencia Este equipo utiliza el sistema de protecci n contra cortocircuito...

Страница 40: ...the power cord removed from the power supply module s before accessing the chassis interior to install or remove system components 250V 20A Waarschuwing Dit product is afhankelijk van de kortsluitbeve...

Страница 41: ...tado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me doit tre d branch de toutes les sourc...

Страница 42: ...arnung Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o...

Страница 43: ...eug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m glich Advertencia Esta unidad ha sido dise ada para instalaci n en reas de acceso restringido S lo puede obtenerse acceso a una d...

Страница 44: ...ame or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een...

Страница 45: ...ecommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta Reemplazar la bat...

Страница 46: ...ellen dass der Einheit kein trom zugef hrt wird m ssen alle Verbindungen entfernt werden Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por comple...

Страница 47: ...System in Betrieb ist treten auf der R ckwandplatine gef hrliche Spannungen oder Energien auf Vorsicht bei der Wartung Advertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero...

Страница 48: ...ie Installation der Ger te muss den Sicherheitsstandards entsprechen Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichti...

Страница 49: ...onal laws and regulations Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Attention L quipement doit tre install conform ment aux normes lectriqu...

Страница 50: ...age de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning The fans might still be...

Страница 51: ...tfernt Advertencia Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis Mandtenga los dedos los destornilladores y todos los objetos lejos de las aberturas del v...

Страница 52: ...CSA Supermicro UL CSA UL CSA Warnung Bei der Installation des Produkts die zur Verf gung gestellten oder benannt Anschlusskabel Stromkabel und Netzteile Verwendung anderer Kabel und Adapter kann zu e...

Страница 53: ...s dispositivos el ctricos que los productos designados por Supermicro solamente Attention Lors de l installation du produit utilisez les bables de connection fournis ou d sign L utilisation d autres c...

Страница 54: ...abels stroomkabels en adapters Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand Elektrisch apparaat en veiligheidsinformatiebladen wet verbiedt het gebruik van UL of C...

Страница 55: ...ding keep one hand under the center of the board to support it when handling The following measures are generally sufficient to protect your equipment from electric static discharge Precautions Use a...

Страница 56: ...oard PDB and the drives backplane board Connecting Data Cables The cables used to transfer data from the peripheral devices have been carefully routed in preconfigured systems to prevent them from blo...

Страница 57: ...r cord last and always remove it before adding removing or changing any hardware components Make sure that you install the processor into the CPU socket before you install the CPU heatsink Note Make s...

Страница 58: ...ARNING Press down on Load the Lever labeled Close 1st Pull lever away from the socket 3 With the lever labeled Close 1st fully retracted gently push down on the Open 1st lever to open the load plate L...

Страница 59: ...PU on the socket Do not move the CPU horizontally or vertically Do not rub the CPU against the surface or against any pins of the socket to avoid damaging the CPU or the socket Caution You can only in...

Страница 60: ...ate with the CPU inside the socket Lock the lever labeled Close 1st first then lock the lever labeled Open 1st second Use your thumb to gently push the load levers down to the lever locks OPEN1st OPEN...

Страница 61: ...se before you re install the heatsink Warning We do not recommend removing the CPU or the heatsink If you do need to remove the heatsink please follow the instructions below to prevent damage to the C...

Страница 62: ...the slot until the module snaps into place 6 Press the release tabs to the locking positions to secure the DIMM module into the slot Reverse the steps above to remove the DIMM modules from the motherb...

Страница 63: ...Processor and Memory Module Population for Optimal Performance Number of CPUs DIMMs CPU and Memory Population Configuration Table For memory to work properly please follow the tables below 1 CPU 2 DI...

Страница 64: ...pport and updates please refer to the SMC Recommended Memory List posted on our website at http www supermicro com support resources mem cfm Intel E5 2600 v2 Series Processor UDIMM Memory Support 3 SP...

Страница 65: ...port and updates please refer to the SMC Recommended Memory List posted on our website at http www supermicro com support resources mem cfm Intel E5 2600 Series Processor UDIMM Memory Support 3 SPC Ra...

Страница 66: ...ecommended Memory List posted on our website at http www supermicro com support resources mem cfm Intel E5 2600 v2 Series Processor RDIMM Memory Support 3 SPC Ranks Per DIMM Data Width Memory Capacity...

Страница 67: ...commended Memory List posted on our website at http www supermicro com support resources mem cfm Intel E5 2600 Series Processor RDIMM Memory Support 3 SPC Ranks Per DIMM Data Width Memory Capacity Per...

Страница 68: ...please refer to the SMC Recommended Memory List posted on our website at http www supermicro com support resources mem cfm Intel E5 2600 v2 Series Processor LRDIMM Memory Support 3 SPC Ranks Per DIMM...

Страница 69: ...GB See the Note Below Speed MT s and Voltage Validated by Slot per Channel SPC and DIMM Per Channel DPC 3 Slots Per Channel 1DPC 2DPC 3DPC 1 35V 1 5V 1 35V 1 5V 1 35V 1 5V QRx4 DDP 16GB 32GB 1066 1066...

Страница 70: ...1 JBR1 1 JP6 JP7 CPLD1 JBT1 HDD_ACT_LED1 JI2C2 JI2C1 JBAT1 CPU2 BIOS PCH SLOT4 PCIE E 2 0X4 CPU1 SLOT3 PCI E 3 0X8 CPU1 SLOT2 PCI E 3 0X8 CPU1 SLOT1 PCI E X16 PROPRIETARY SLOT P2 DIMMH2 P2 DIMMH1 P2 D...

Страница 71: ...ified by the manufacturer Do not install the onboard battery upside down to avoid possible explosion 3 The X9DRFF 7TG includes 10 GB Ethernet ports 4 Jumpers not indicated are for test purposes only 5...

Страница 72: ...External BMC I2 C Header for IPMI Card JPI2 C1 Power Supply SMBbus I2 C Header JPW1 JPW2 8 pin Power Connectors JPW3 4 pin Power Connector JSD1 SATA Device Power Connector JTPM1 TPM Trusted Platform M...

Страница 73: ...tions 12V 8 pin PWR JPW1 2 Pin Definitions Pins Definition 1 4 Ground 5 8 12V 12V 4 pin PWR JPW3 Pin Definitions Pins Definition 1 Ground 2 Ground 3 5V SB 4 PS_ON_N HDD PWR Pin Definitions Pins Defini...

Страница 74: ...ted next to the UID switch on the front panel When you press the UID switch the UID LED Indicator will be turned on Press the UID switch again to turn off the UID LED The UID Indicator provides easy i...

Страница 75: ...Pin Definitions Pin Definition Pin Definition 1 NC 2 NC 3 Ground 4 Data 5 Load 6 Ground 7 Clock 8 NC NC indicates no connection Fan Headers This serverboard has eight 4 pin Fan1 Fan8 and one 3 pin Rea...

Страница 76: ...witch again to turn off the LED indicator The UID switch provides easy identification of a system unit that may be in need of service See the tables on the right for more information UID Switch UID Pi...

Страница 77: ...is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To Clear CMOS 1 First power down th...

Страница 78: ...right for jumper settings BMC Enable Jumper JPB1 allows you to enable the embedded BMC Baseboard Management Controller to provide IPMI 2 0 support on the motherboard See the table on the right for jum...

Страница 79: ...les at right for more information IPMI LAN Link Speed LED Left Activity LED Right Color Status Definition Off Off No Connection Green Solid Link Speed Left 100 Mb s Amber Blinking Activity Right Activ...

Страница 80: ...D Active Off HDD Disabled or Failed SAS Heartbeat LED A SAS Heartbeat LED is located at SAS_HB_LED1 on the motherboard When LEDS2 is blinking SAS is working properly SAS Heartbeat LED SAS_HB_LED1 Stat...

Страница 81: ...SATA Ports 2 8 and S SATA 0 support SATA 2 0 In addition eight SAS ports L SAS 0 7 supported by the LSI SAS 2208 Controller are also located on the serverboards See the table on the right for pin defi...

Страница 82: ...ectory and locate the ISO file for your motherboard Download this file to create a CD DVD of the drivers and utilities it contains You may also use a utility to extract the ISO file if preferred Anoth...

Страница 83: ...is called SD III Client The SuperDoctor III program allows you to monitor the environment and operations of your system SuperDoctor III displays crucial system information such as CPU temperature sys...

Страница 84: ...User s Manual can be downloaded from the Supermicro web site at http www supermicro com products accessories software SuperDoctorIII cfm For Linux we recommend that you use the SuperoDoctor II applica...

Страница 85: ...urer CR2032 Dispose of used batteries according to the manufacturer s instructions Figure 5 7 Installing the Onboard Battery LITHIUM BATTERY BATTERY HOLDER Please handle used batteries carefully Do no...

Страница 86: ...5 32 FatTwin F617H6 FTL FTPTL User s Manual Notes...

Страница 87: ...very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded me...

Страница 88: ...6 2 Control Panel The control panel for each node is located on the front of the chassis The LEDs inform you of system status See Chapter 3 for details on the LEDs and the control panel buttons Ether...

Страница 89: ...e power supply 3 If your system has dual redundant power supplies remove the cords from both power supplies 4 Disconnect the cord from the power strip or wall outlet 6 4 Removing Nodes from the Chassi...

Страница 90: ...emoving the Node Cover 1 Remove the power cord from the rear of the node as described in Section 6 3 and remove the node from the chassis as described in Section 6 4 Place the node on a flat stable su...

Страница 91: ...onfiguration These instructions apply to fixed 3 5 hard drives Only enterprise level hard drives are recommended for use in Supermicro chassis F414IS R1K62B Chassis Nodes and Their Hard Drives Node 4...

Страница 92: ...on of the latch 5 Lift the hard drive up and out of the node 6 Remove the four screws securing the hard drive to the hard drive tray and set them aside for later use 7 Remove the hard drive from the t...

Страница 93: ...ition to the node components shown there are eight exhaust fans and two power supplies located in the rear of the chassis body Figure 6 5 Configuration of the Node Four 3 5 HDDs Seven 3 5 HDDs Backpla...

Страница 94: ...tructions below Removing the Backplane Removing the Backplane from the Node 1 Power down the node with the operating system and remove the cord from the rear of the power supply as described in Sectio...

Страница 95: ...1 6 1 7 6 Install a replacement backplane onto the protection cover and secure with the screws previously set aside 7 Place the protection cover in the node and secure it to the floor of the node wit...

Страница 96: ...in Section 6 4 Remove the node cover as described in Section 6 5 2 Remove the screws securing the power adapter board to the floor of the node and set them aside for later use 3 Lift the power adapter...

Страница 97: ...s included in the F414IS accessories packaging Some motherboards require additional screws for heatsinks general components and or non standard security Optional standoffs are used for these motherboa...

Страница 98: ...mounting holes in the node with those in the motherboard Add or remove standoffs as needed 3 Secure the motherboard to the floor of the node tray using the rounded Phillips head screws included for th...

Страница 99: ...Cards PCIE Slot Setup The nodes of some F414IS chassis models support two low profile expansion cards To install the low profile expansion cards follow the instructions on the following pages Figure...

Страница 100: ...move the mounting screw which secures the PCIE slot cover in the riser card bracket and set this aside for later use 4 Remove the PCIE slot cover by sliding it sideways and out of the PCIE slot and se...

Страница 101: ...Installation Complete In most cases the node power supplies and fans are pre installed If you need to install fans or power supplies continue to the Systems Fan and Power Supply sections of this chapt...

Страница 102: ...when replacing fans Replacing an Exhaust Fan 1 Determine the location of the failed fan 2 Power down the node with the operating system 3 Remove the power cord from the rear of the node with the fail...

Страница 103: ...Chapter 6 Advanced Chassis Setup 6 17 Figure 6 14 Removing the System Fans from the Fan Housing Squeeze the Release Tabs...

Страница 104: ...t is within the maximum output power PWS 2K02P 1R Power Ratings Region Input Power Source Current Rating Maximum Output Power North America 100 120V 50 60Hz 12 0 10 5A 1100W 200 240V 50 60Hz 11 0 9 8A...

Страница 105: ...nits can be ordered directly from Supermicro See the contact information in the Preface of this manual Changing the Power Supply 1 Power down the system and disconnect the AC power cord on the back of...

Страница 106: ...6 20 FatTwin F617H6 FTL FTPTL User s Manual Notes...

Страница 107: ...rame displays all the options that can be configured Grayed out options cannot be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend...

Страница 108: ...ity From the main menu you can access the other setup screens An AMI BIOS identification string is displayed at the left bottom corner of the screen below the copyright message Warning Do not upgrade...

Страница 109: ...SS format e g 15 32 52 Supermicro X9DRFF 7G 7TG Version This item displays the SMC version of the BIOS ROM used in this system Build Date This item displays the date that the BIOS ROM was built Memor...

Страница 110: ...is pressed if an error occurs The options are Disabled and Enabled Interrupt 19 Capture Interrupt 19 is the software interrupt that handles the boot disk function When this item is set to Enabled the...

Страница 111: ...ct Power On for the system power to be turned on after a power loss Select Last State to allow the system to resume its last state before a power loss The options are Power On Stay Off and Last State...

Страница 112: ...Enabled to use the processor s second core and above Please refer to Intel s website for more information The options are All 1 2 4 and 6 Limit CPUID Maximum Use this feature to set the maximum CPU I...

Страница 113: ...led for DCU Data Cache Unit IP Prefetcher support which will prefetch IP addresses to improve network connectivity and system performance The options are Enabled and Disabled Intel Virtualization Tech...

Страница 114: ...C6 State ACPI C3 to the operating system During the CPU C6 State the power to all cache is turned off The options are Enabled and Disabled CPU C7 Report Available when Power Technology is set to Cust...

Страница 115: ...he time period during which short duration power in watts is maintained The default setting is 0 Chipset Configuration North Bridge This feature allows the user to configure the settings for the Intel...

Страница 116: ...e PCI Express lanes are distributed between the PCI Exp Root ports CPU 1 Slot J1 PCI E 3 0 x16 Link Speed Select GEN1 to enable PCI Exp Generation 1 support for Slot J1 Select GEN2 to enable PCI Exp G...

Страница 117: ...onfiguration Current QPI Link Speed This item displays the current speed of the QPI Link Current QPI Link Frequency This item displays the frequency of the QPI Link Isoc Select Enabled to enable Isoch...

Страница 118: ...ical copies of all data in memory for data backup When Lockstep is selected the motherboard uses two areas of memory to run the same set of operations in parallel The options are Independent Mirroring...

Страница 119: ...ed and sent to the requestor the original source Memory is updated as well Select Enabled to use Demand Scrubbing for ECC memory correction The options are Enabled and Disabled Data Scrambling Select...

Страница 120: ...ort 60h 64h emulation support for the legacy USB keyboard so that it can be fully supported by the operating systems that does not recognize a USB device The options are Disabled and Enabled EHCI Hand...

Страница 121: ...ctive state when I O activity resumes The options are Enabled and Disabled Port 0 5 Hot Plug Select Enabled to enable hot plug support for a particular port which will allow the user to change a hardw...

Страница 122: ...Payload Select Auto to allow the system BIOS to automatically set the maximum payload value for a PCI E device to enhance system performance The options are Auto 128 Bytes and 256 Bytes 512 Bytes 1024...

Страница 123: ...computer using a network device Select PXE Preboot Execution Environment to use an PXE Option ROM to boot the computer using a network device The options are PXE iSCSI and FCoE Load Onboard LAN1 Optio...

Страница 124: ...te with the client computer which is the remote computer used by the user Terminal Type This feature allows the user to select the target terminal emulation type for Console Redirection Select VT100 t...

Страница 125: ...edirection to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer is full Send a Start signal to start sending data when the receiving buffer...

Страница 126: ...to specify how the host computer will exchange data with the client computer which is the remote computer used by the user Out of Band Management Port The feature selects a serial port used by the Mi...

Страница 127: ...uctions In this setting power to the CPU s and RAM is maintained but RAM is refreshed Select Suspend Disabled to use power reduced mode Power will only be supplied to limited components such as RAMs t...

Страница 128: ...item to schedule an operation for the security device The options are None Enable Take Ownership Disable Take Ownership and TPM Clear Note Upon system reset the computer will reboot in order to execut...

Страница 129: ...anagement BIOS event logging during system boot The options are Enabled and Disabled Runtime Error Logging Support Select Enabled to support runtime error logging The options are Enabled and Disabled...

Страница 130: ...hen the SMBIOS event log is full The options are Do Nothing and Erase Immediately SMBIOS Event Log Standard Settings Log System Boot Event Select Enabled to log system boot events The options are Disa...

Страница 131: ...in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Enabled and Disabled Erasing Settings Erase SEL Select...

Страница 132: ...Yes Configuration Address Source Use this feature to select the source of the IP address for this computer If Static is selected you will need to know the IP address of this computer and enter it to t...

Страница 133: ...ot Priority 1st Boot Device 2nd Boot Device 3rd Boot Device etc Use these items to specify the sequence of boot device priority Delete Boot Option Use this feature to select a boot device to delete fr...

Страница 134: ...es when a password entry is required If Setup is selected the user is required to enter a password upon entering the BIOS setup utility If Always is selected the user is required to enter a password u...

Страница 135: ...and Reset When you have completed the system configuration changes select this option to save the changes and reboot the computer so that the new system configuration settings can take effect Select...

Страница 136: ...s as the user s defaults When the dialog box appears asking you if you want to save values as user s defaults click Yes to save the current values as user s default settings or click No to keep the de...

Страница 137: ...s or up to 128 GB of unbuffered ECC non ECC UDIMMs at DDR3 1600 1333 1066 800 MHz speed and 1 GB 2 GB 4 GB 8 GB 16 GB or 32 GB size Note refer to Chapter 5 for details and to our web site for updates...

Страница 138: ...ing The system has eight 8 8 cm PWM system cooling fans in the rear of the chassis System Input Requirements AC Input 1000W Output 100 120V 12 10A 50 60Hz 1200W Output 120 140V 12 10A 50 60Hz 1620W Ou...

Страница 139: ...l speed 4 Only 10 HDDs per node can be populated 5 Only 9 HDDs per node can be populated and fans running at full speed 6 Only 9 HDDs per node can be populated 7 Only 10 HDDs and one AOC per node can...

Страница 140: ...to fully indemnify defend and hold Supermicro harmless for and against any and all claims demands actions litigation and proceedings of any kind arising out of or related to such ultra hazardous use...

Отзывы: