Страница 1: ...USER S MANUAL Revision 1 0 A Server AS 3014TS i...
Страница 2: ...Class A device or in residential environment for Class B device This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer...
Страница 3: ...uals Product drivers and utilities https www supermicro com wdl driver Product safety info http www supermicro com about policies safety_information cfm If you have any questions please contact our su...
Страница 4: ...llation 2 1 Removing Power 18 2 2 Accessing the System 18 Removing the Side Covers 18 2 3 Motherboard Components 20 Processor and Heatsink Installation 20 Memory Support 27 Memory Support 27 DIMM Modu...
Страница 5: ...5 4 2 Driver Installation 57 4 3 SuperDoctor 5 58 4 4 BMC 59 BMC ADMIN User Password 59 Chapter 5 UEFI BIOS 5 1 Introduction 60 Starting the Setup Utility 60 5 2 Main Setup 61 5 3 Advanced 63 5 4 IPMI...
Страница 6: ...V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermi...
Страница 7: ...g fan FAN 0124L4 1 900W power supply PWS 903PQ 1 1 2 Unpacking the System Inspect the box the SuperServer AS 3014TS i was shipped in and note if it was damaged in any way If any equipment appears dama...
Страница 8: ...EPYC 7002 7003 Series Processor Socket Type SP3 Memory Eight DIMM slots to support up to 2TB of registered ECC DDR4 3200 SDRAM Chipset System on Chip Expansion Slots Five PCIe 4 0 x16 low profile slot...
Страница 9: ...erver but maintains standby power Reset Button Reboots the system Power LED Steady on Power on Blinking at 4Hz Checking BIOS BMC integrity Blinking at 4Hz and i LED is blue BIOS firmware updating Two...
Страница 10: ...y Red solid with Power LED blinking green Fault detected Blue and red blinking at 10 Hz Recovery mode Blue solid UID has been activated locally to locate the server in a rack environment Blue blinking...
Страница 11: ...Features The CSE 732i 903B is a mid tower chassis See the illustration below for the features included on the front of the chassis Figure 1 2 System Front View Control Panel see previous section Remo...
Страница 12: ...s Feature Description Power Supply 900W Gold Level power supply I O Ports Rear I O port panel see Section 3 3 for details PCIe Slots PCI expansion slots see table below for details Power Supply Rear I...
Страница 13: ...nking Green Indicates that the power supply is plugged in and turned off by the system Blinking Amber Indicates that the power supply has a warning condition and continues to operate Solid Amber Indic...
Страница 14: ...USB4 5 JF1 LE1 I SATA0 I SATA1 JSD1 JSD2 JL1 I SATA2 3 JD1 JSTBY1 SGPIO1 JOH1 JUID FAN1 JPI2C1 JPWR2 JPWR1 IPMI LAN USB2 3 LAN1 LAN2 VGA UID SW UID LED BT1 JPL1 JWD1 M 2 M2 M 2 M1 I SATA4 5 I SATA6 7...
Страница 15: ...reen System power OK Connector Description Battery BT1 Onboard CMOS battery JNCSI1 NCSI header COM 1 Rear panel COM port 1 FAN 1 5 A B System cooling fan headers IPMI_LAN Dedicated IPMI LAN port JF1 F...
Страница 16: ...8 pin CPU core power supply connector JPWR2 12V 8 pin CPU core power supply connector JD1 Front panel external speaker header JPI2C1 Power supply SMBus I2 C header LAN1 LAN2 Back panel LAN1 LAN2 conn...
Страница 17: ...0 15 Slot 3 PCIe x16 G0 0 15 G2 0 7 G2 8 11 SATA 0 7 or NVMe 0 1 G2 12 15 PCIe x4 M 2 PCIe x4 M 2 PCIe x8 Slot 2 G3 8 15 LSI 3008 Mini SAS HD Mini SAS HD NVMe 2 3 or SATA 8 15 G3 0 7 P0 P1 P2 P3 Slot...
Страница 18: ...ents or when replacing a non redundant power supply 1 Use the operating system to power down the system 2 After the system has completely shut down disconnect the AC power cord s from the power strip...
Страница 19: ...19 Chapter 2 Maintenance and Component Installation Figure 2 1 Removing the Left and Right Side Covers Screws Screws...
Страница 20: ...nstall the CPU heatsink If you buy a CPU separately make sure that you use an AMD certified heatsink only Make sure to install the motherboard into the chassis before you install the CPU heatsink When...
Страница 21: ...up to its stopping position 3 Lift the rail frame up by gripping the lift tabs near the front end of the rail frame While keeping a secure grip of the rail frame lift it to a position so you can do th...
Страница 22: ...ed Grip the handle of the carrier frame CPU package assembly from its shipping tray and while gripping the handle align the flanges of the carrier frame onto the rails of the rail frame so its pins wi...
Страница 23: ...rail frame till it securely rests in upright position Then remove the PnP cover cap from the CPU socket below Grip the two lift tabs marked Remove at the middle of the cap and pull vertically upwards...
Страница 24: ...s spring loaded and has to be held in place before it is secured Important Use a torque screwdriver set it at 16 1 kgf cm 14 0 lbf in with a Torx T20 screw head bit to prevent damage to the CPU 10 Pla...
Страница 25: ...s securely over the four screw holes on CPU package on the socket frame 12 Using a diagonal pattern tighten the four screws down on the heatsink in a clockwise fashion till it is secure The heatsink w...
Страница 26: ...rail frame is spring loaded so be careful lifting it up into a vertical position 5 Grip the handle of the carrier frame and pull upwards to extract it from the rail frame Return the carrier frame CPU...
Страница 27: ...LRDIMM LRDIMM 3DS DDR4 Memory Modules with AMD EPYC 7002 700 Processors Type DIMM Population Maximum DIMM Capacity GB Maximum Frequency MHz DIMM1 1 Channel 8 Channel RDIMM 1R 32GB 256GB 3200 2R or 2DR...
Страница 28: ...dules of the same type size and speed should be installed Mixed DIMM speeds can be installed However all DIMMs will run at the speed of the slowest DIMM The motherboard will support odd numbered modul...
Страница 29: ...tem 3 All graphics including the layout drawing are for reference only Your system components may or may not look the same as shown in this user guide MEGERAC LICENSE MAC CODE IPMI CODE BAR CODE C A C...
Страница 30: ...system place it on its side and remove the left side cover 2 Use the inside release latch to swing the protective bracket out as shown below 3 Remove the blank PCI shields that covers the chassis slot...
Страница 31: ...holder with the positive side facing up Then push the other side down until the clamp snaps over it Note Handle used batteries carefully Do not damage the battery in any way a damaged battery may rel...
Страница 32: ...compatible storage drives see the H12SSL i motherboard web page 3 5 Drive Cage The removable drive cage is accessed by removing the left chassis cover These drives are not hot swap power must be remov...
Страница 33: ...itional optional screw at the middle of the drive Figure 2 6 Installing a 3 5 Drive into a Tray 2 5 Drive Cage The removable drive cage is accessed by removing the left chassis cover These drives are...
Страница 34: ...ert the new hard drive into the hard drive carrier 7 Insert the hard drive carrier into the hard drive cage sliding it towards the back of the hard drive cage until it clicks into a locked position No...
Страница 35: ...moving the left cover as previously described Installing a 3 5 Device 1 Remove the front bezel from the chassis by lifting it upwards from the bottom and pulling it off the front of the chassis 2 Remo...
Страница 36: ...VROC appendix in this manual instead Ejecting a Drive 1 IPMI Storage Physical View 2 Select Device and click Eject After ejecting the drive Status LED indicator turns green 3 Remove the drive Slot is...
Страница 37: ...as previously described 1 Insert the four rubber pins through the front fan bracket and into the mounting holes in the front fan 2 Pull the rubber pins through the mounting holes of the system fan to...
Страница 38: ...down the system and removing the left cover as previously described 1 Insert the four rubber pins into the four mounting holes surrounding the fan grill on the rear of the chassis 2 Pull the rubber pi...
Страница 39: ...supply to the chassis which are located on the rear of the chassis Set these screws aside for later use 3 Gently lift the power supply out of the chassis 4 Replace the failed power supply with an ide...
Страница 40: ...endix A before installing or removing components 3 1 Power Connections Two power connections on the H12SSL i must be connected to the power supply 24 pin Primary ATX Power JPWR3 8 pin Auxilliary Power...
Страница 41: ...nitions Pin Definition 1 Ground Black 2 12V Red 3 Tachometer 4 PWM Control 12V 8 pin Auxilliary Power Connector JPWR1 JPWR1 is an 8 pin ATX power input to provide core power to the processor Refer to...
Страница 42: ...5 JNVME1 support SATA 3 0 drives requiring a break out cable SATA Connectors Pin Definitions Pin Signal 1 Ground 2 SATA_TXP 3 SATA_TXN 4 Ground 5 SATA_RXN 6 SATA_RXP 7 Ground Number of Supported Drive...
Страница 43: ...link for more information on TPM http www supermicro com manuals other TPM pdf Trusted Platform Module Header Pin Definitions Pin Definition Pin Definition 1 LCLK 2 GND 3 LFRAME 4 Key 5 LRESET 6 N C...
Страница 44: ...USB_P 10 x Overheat LED Fan Fail JOH1 The JOH1 header is used to connect an LED indicator to provide warnings of chassis overheating or fan failure This LED will blink when a fan failure occurs Refer...
Страница 45: ...ion on your system IPMB Header Pin Definitions Pin Definition 1 Data 2 Ground 3 Clock 4 No Connection Speaker JD1 If you wish to use an external speaker attach an external speaker to pins 6 7 See the...
Страница 46: ...rol Panel Pins Power Button The Power Button connection is located on pins 1 and 2 of JF1 Momentarily contacting both pins will power on off the system This button can also be configured to function a...
Страница 47: ...ED Pin Definitions JF1 Pin Definition 5 Vcc 6 Ground UID LED The UID LED is on pins 7 and 8 of JF1 Connect the front panel UID LED to this header to indicate when the rear UID switch is turned on Refe...
Страница 48: ...the table below for pin definitions NMI Button Pin Definitions JF1 Pin Definition 19 Control 20 Ground Power LED Pin Definitions JF1 Pin Definition 15 5V 16 Ground HDD LED The HDD LED connection is l...
Страница 49: ...LAN Port 5 USB 2 3 0 8 LAN Port 2 3 USB 0 3 0 6 USB 3 3 0 9 VGA Port Universal Serial Bus USB Ports There are four USB 3 0 ports USB0 1 and USB2 3 on the I O back panel These support the type A conne...
Страница 50: ...h rear and front UID LED indicators will turn on Press the UID switch again to turn off the LED indicators The UID Indicator provides easy identification of a system that may be in need of service Not...
Страница 51: ...Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearin...
Страница 52: ...JPG1 allows you to enable or disable the VGA port The default position is on pins 1 and 2 to enable VGA See the table below for jumper settings VGA Enable Disable Jumper Settings JPG1 Jumper Setting...
Страница 53: ...n Blinking BMC Normal Green Fast Blinking BMC Initializing UID LED Indicator The rear LED1 is located next to the UID switch The front UID LED is located on the front panel When you press the UID swit...
Страница 54: ...n and all the system power rails are ready When the system is turned off or any one of the system power rails fail this LED will turn off Turn off the system and unplug the power cable before removing...
Страница 55: ...r website at www supermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a...
Страница 56: ...d the driver browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID choo...
Страница 57: ...Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the flash drive or...
Страница 58: ...erts via email or Simple Network Management Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoc...
Страница 59: ...em modules There are several BIOS settings that are related to BMC For general documentation and information on BMC visit our website at www supermicro com en solutions management software bmc resourc...
Страница 60: ...ses when other keys are used such as F1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be confi...
Страница 61: ...e Use this option to change the system date and time Highlight System Date or System Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow keys to move between f...
Страница 62: ...tem displays the date when the version of the BIOS ROM used in the system was built CPLD Version This item displays the CPLD version of the BIOS ROM used in the system Memory Information Total Memory...
Страница 63: ...ubmenu items Boot Feature Quiet Boot Use this feature to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to display the POST messages Select Enabled to...
Страница 64: ...matically reboot the system from a specified boot device after its initial boot failure The options are Disabled Legacy Boot and EFI Boot Power Configuration Watch Dog Function If enabled the Watch Do...
Страница 65: ...Fixed PSP Recovery BL Ver SMU FW Version ABL Version PSP Directory Level 2 Updateable PSP Bootloader Version SMU FW Version ABL Version ACPI Settings PCI AER Support The options are Disabled and Enabl...
Страница 66: ...ial port specified by the user Select Auto to allow the BIOS to automatically assign the base I O and IRQ address The options are Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5...
Страница 67: ...the same speed is used in the host computer and the client computer A lower transmission speed may be required for long and busy lines The options are 9600 19200 38400 57600 and 115200 bits per secon...
Страница 68: ...resolution support The options are Disabled and Enabled Legacy OS Console Redirection Use this feature to select the number of rows and columns used in Console Redirection for legacy OS support The op...
Страница 69: ...ssion size for Console Redirection The options are 7 and 8 Parity A parity bit can be sent along with regular data bits to detect data transmission errors Select Even if the parity bit is set to 0 and...
Страница 70: ...or designed for the Windows OS The options are VT100 LINUX XTERMR6 SC0 ESCN and VT400 Redirection After BIOS POST Use this feature to enable or disable legacy Console Redirection after BIOS POST When...
Страница 71: ...is item to set the flow control for Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer is full Send a Start signal to...
Страница 72: ...g sets the number of CCDs to be used The options include Auto 2 CCDs 3 CCDs 4 CCDs and 6 CCDs Core Control This sets the number of cores to be used by your system Once this option has been used to rem...
Страница 73: ...figuration Determinism Control Use this setting to configure the Determinism Slider Options include Manual and Auto cTDP Control Use this setting to configure the cTDP Control Options include Manual a...
Страница 74: ...eave memory blocks across the DRAM chip for node 0 The options are Disabled and Auto BankGroupSwap This setting controls the Bank Group Swap The options are Enabled Disabled and Auto DRAM Scrub Time T...
Страница 75: ...support or the device vendor defined firmware support The options are Vendor Defined Firmware and AMI Native Support M 2 AHCI Firmware Source Use this setting to select between the AMI Native firmware...
Страница 76: ...ROM Use this setting to select which option ROM is to be loaded for onboard LAN1 on the system The options include Disabled Legacy and EFI Onboard LAN2 Option ROM Use this setting to select which fir...
Страница 77: ...A 0 7 This setting selects NVMe or SATA engine for the hybrid port When Auto is selected JCFG1 2 jumper determines the behavior for JNVMe0 1 The options are Auto NVME and SATA JNVMe1 SATA 8 15 This se...
Страница 78: ...ions only The options are Enabled Disabled and Auto XHCI Hand Off This is a work around solution for operating systems that do not support XHCI Extensible Host Controller Interface hand off The XHCI o...
Страница 79: ...tions are Updare Delte and Export HTTP Boot Configuration HTTP Boot One Time When the HTTP boot option is created this option when enabled will allow the system to boot via HTTP the first time and rev...
Страница 80: ...isabled the following items will become available for configuration Local IP Address This item sets and displays the Local IP address for this computer This should be in decimal and in dotted quad for...
Страница 81: ...on Enroll Certification using File Use this feature to enroll certification from a file Certification GUID Use this feature to input the certification GUID Commit Changes and Exit Use this feature to...
Страница 82: ...tform Management Interface IPMI settings BMC Firmware Revision This item indicates the IPMI firmware revision used in your system IPMI STATUS This item indicates the status of the IPMI firmware instal...
Страница 83: ...onfiguration IPMI LAN Selection This item displays the IPMI LAN setting The default setting is Failover IPMI Network Link Status This item displays the IPMI Network Link status The default setting is...
Страница 84: ...port This section displays configuration features for IPv6 support IPv6 Support Use this feature to enable IPV6 support The options are Enabled and Disabled If the item above is set to Enabled the fol...
Страница 85: ...BIOS Event Log Select Enabled to enable SMBIOS System Management BIOS Event Logging during system boot The options are Disabled and Enabled Erasing Settings Erase Event Log Select Yes to erase all err...
Страница 86: ...bled MECI Multiple Event Count Increment Enter the increment value for the multiple event counter Enter a number between 1 to 255 The default setting is 1 METW Multiple Event Count Time Window This it...
Страница 87: ...te a new or change an existing Administrator password Note that if the Administrator Password is erased the User Password will be cleared as well Password Check Select Setup for the system to check fo...
Страница 88: ...ndor Keys Provision Factory Defaults This feature is to provision the default secure boot keys set by the manufacturer when system is in the Setup mode The options are Disabled and Enabled Restore Fac...
Страница 89: ...re Boot keys set by the manufacturer The options are Disabled and Enabled Key Exchange Keys Set New Key Select Yes to load the KEK from the manufacturer s defaults Select No to load the KEK from a fil...
Страница 90: ...add the DBT from the manufacturer s defaults list to the existing DBT Select No to load the DBT from a file The options are Yes and No OsRecovery Signature This item uploads and installs an OSRecover...
Страница 91: ...tting is DUAL LEGACY to EFI Support This option Disables or Enables the system to boot to an EFI OS after the boot failed from the legacy boot order FIXED BOOT ORDER Priorities This option prioritizes...
Страница 92: ...system will boot during startup The settings are any pre defined boot device UEFI Application Boot Priorities This feature allows the user to specify which UEFI devices are boot devices UEFI Boot Ord...
Страница 93: ...making any permanent changes to the system configuration and reboot the computer Select Discard Changes and Exit from the Exit menu and press Enter Save Changes and Reset Select this option to reset...
Страница 94: ...maximum performance Save as User Defaults To set this feature select Save as User Defaults from the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use...
Страница 95: ...assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis These...
Страница 96: ...o considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar...
Страница 97: ...n dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan he...
Страница 98: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...
Страница 99: ...s del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l instal...
Страница 100: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...
Страница 101: ...els aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment Warn...
Страница 102: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...
Страница 103: ...una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s u...
Страница 104: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...
Страница 105: ...anbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All con...
Страница 106: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...
Страница 107: ...ertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques cir...
Страница 108: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...
Страница 109: ...e elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled accordin...
Страница 110: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...
Страница 111: ...tornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient tou...
Страница 112: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSA Supermicro Supermicro UL CSA UL CSA Supermicro U...
Страница 113: ...le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto uti...
Страница 114: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...
Страница 115: ...IOS block a main BIOS image The boot block contains critical BIOS codes including memory detection and recovery codes for the user to flash a new BIOS image if the original main BIOS image is corrupte...
Страница 116: ...very process DO NOT INTERRUPT THIS PROCESS UNTIL IT IS FINISHED Note If you cannot locate the Super ROM file in your driver disk visit our website at www supermicro com to download the BIOS image into...
Страница 117: ...or SUM Please refer to these SUPERMICRO software related videos Activate OOB license https www youtube com watch v V4spX_DOV7I SUPERMICO BIOS Update https www youtube com watch v S8z6iOEHGwY If the B...
Страница 118: ...4 0 x16 low profile slots Two PCIe 4 0 x8 low profile slots M 2 Interface 2 PCIe 4 0 x4 M 2 Form Factor 2280 22110 Motherboard H12SSL i 12 x 9 6 305 x 244mm Chassis CSE 732i 903B mid tower WxHxD 7 6...
Страница 119: ...EN 61000 4 5 BS EN 61000 4 6 BS EN 61000 4 8 BS EN 61000 4 11 Product Safety 2014 35 EU LVD Directive UL CSA 62368 1 USA and Canada Electrical Equipment Safety Regulations 2016 IEC BS EN 62368 1 Envi...