2-8
SUPERSERVER 4048B-TR4FT USER'S MANUAL
Figure 5-6: Installing into a Rack
Standard Chassis Installation
Installing the Chassis into a Rack
1.
Confirm that the inner rails are properly installed on the chassis.
2.
Confirm that the outer rails are correctly installed on the rack.
3. Pull the middle rail out from the front of the outer rail and make sure that the
ball-bearing shuttle is at the front locking position of the middle rail.
4. Align the chassis inner rails with the front of the middle rails.
5. Slide the inner rails on the chassis into the middle rails, keeping the pressure
even on both sides, until the locking tab of the inner rail clicks into the front of
the middle rail, locking the chassis into the fully extended position.
6. Depress the locking tabs of both sides at the same time and push the chassis
all the way into the rear of the rack.
7. If necessary for security purposes, use screws to secure the chassis handles
to the front of the rack.
Warning:
In any instance of pulling the system from the rack, always use a rack lift
and follow all associated safety precautions.
Ball-Bearing
Shuttle
Note:
figures are for illustrative purposes only. Always install servers into racks
from the bottom up.
Содержание 4048B-TR4FT
Страница 1: ...USER S MANUAL Revision 1 0c SuperServer 4048B TR4FT...
Страница 5: ...v SUPERSERVER 4048B TR4FT USER S MANUAL Notes...
Страница 10: ...x SUPERSERVER 4048B TR4FT USER S MANUAL Notes...
Страница 26: ...2 10 SUPERSERVER 4048B TR4FT USER S MANUAL Notes...
Страница 50: ...4 20 SUPERSERVER 4048B TR4FT USER S MANUAL Notes...
Страница 82: ...5 32 SUPERSERVER 4048B TR4FT USER S MANUAL Notes...
Страница 92: ...6 10 SUPERSERVER 4048B TR4FT USER S MANUAL Notes...
Страница 130: ...7 38 SUPERSERVER 4048B TR4FT USER S MANUAL Notes...
Страница 132: ...A 2 SUPERSERVER 4048B TR4FT USER S MANUAL Notes...