SUPERSERVER 4048B-TR4FT USER'S MANUAL
5-2 Connecting Cables
Now that the processors are installed, the next step is to connect the cables to
the serverboard.
Connecting Data Cables
The cables used to transfer data from the peripheral devices have been carefully
routed in preconfigured systems to prevent them from blocking the flow of cooling
air that moves through the system from front to back. If you need to disconnect
any of these cables, you should take care to reroute them as they were originally
after reconnecting them (make sure the red wires connect to the pin 1 locations). If
you are configuring the system, keep the airflow in mind when routing the cables.
The following cables need to be connected for the SuperServer 4048B-TR4FT
system:
•
One round 76-cm (30") 16-to-16-pin ribbon FP cable (CBL-0071L)
•
One power extension cable; one HDD to two HDD and two FDD
(CBL-0099)
•
Two cross-over mini SAS HD to four SATA HD cable (CBL-SAST-0591)