background image

Printed in U.S.A. © 2014  Innovative Hearth Products LLC

P/N 900247-00, Rev. NC,  01/2014

Innovative Hearth Products

1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210

Innovative Hearth Products

Superior™ Brand Gas Log Set 

Limited Three Year Warranty

THE WARRANTY

Innovative Hearth Products Limited Three Year Warranty ("IHP") warrants your Superior™ brand Gas Log Set ("Product") to be free from defects in materials and workmanship 

at the time of manufacture. The logs and grate carry the Limited Three Year Warranty. After installation, if covered components manufactured by IHP are found to be defec-

tive in materials or workmanship during the Limited Three Year Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, 

repair or replace the covered components. If repair or replacement is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the 

IHP product, whichever is applicable. IHP will also pay IHP prevailing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components. 

THERE ARE EXCLUSIONS AND LIMITATIONS to this Limited Three Year Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of installation. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six 

months after the sale of the Product by an independent IHP dealer, whichever occurs earlier. The warranty shall commence no later than 24 months following the date of 

product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This Limited Three Year Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 

instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.

This warranty is non-transferable and extends to the original owner only. The Product must be  purchased through a listed supplier of IHP and proof of purchase must be 

provided. The following do not carry the Limited Three Year Warranty but are warranted as follows:

Gas components

 – Repair or replacement for one year from the date of installation.

Remote control

 – Repair or replacement for one year from the date of installation.

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component.

Parts not otherwise listed carry a 90 day warranty from the date of installation.

Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or 

unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to burn either 

natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures 

and could result in a fire hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; 

(d) damages, repairs or inefficiency resulting from faulty installation or application of the Product.

This Limited Three Year Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction which are 

not manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to 

any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 

or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.

In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or after 

replacement or repair, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a particular 

use or purpose, and there is no implied condition of fitness for a particular use or purpose.

IHP makes no expressed warranties except as stated in this Limited Three Year Warranty. The duration of any implied warranty is limited to the duration of this expressed 

warranty.

No one is authorized to change this Limited Three Year Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and 

provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of 

this Limited Three Year Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this Limited Three Year Warranty and to decide, in its sole discretion, upon the method of settlement.

To receive the benefits and advantages described in this Limited Three Year Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP. 

Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. 

IHP shall in no event be responsible for any warranty work done by a 

contractor that is not approved without first obtaining LHP's prior written consent.

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/

distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 

IHP Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or visit our website at WWW.SUPERIORFIREPLACES.US.COM.

Содержание VS1824NM

Страница 1: ...that includes instructions stating it has not been tested or should not be used with unvented gas logs This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Pr...

Страница 2: ...ING This is an unvented gas fired heat er It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion...

Страница 3: ...G Do not use a blower insert heat exchanger insert or other accessory not approved for use with this heater SAFETY Continued WARNING Do not allow fans to blow directly into the fireplace Avoid any dra...

Страница 4: ...fire department 5 This heater shall not be installed in a bedroom or bathroom unless installed as a vented appliance see Installing Damper Clamp Accessory for Vented Operation page 11 This gas log set...

Страница 5: ...of vent free heaters Non thermostat models may also be operated as a vented decorative ANSI Z21 60 product by opening flue damper SAFETY PILOT This heater has a pilot with an Oxygen Deple tion Sensin...

Страница 6: ...e whose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the ag AIR FOR COMBUSTION AND VENTILATION Continued gregate input rating of all appliances installed in that space and...

Страница 7: ...Fuel Gas Code or applicable local codes VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space When ventilating to an adjoining unconfined sp...

Страница 8: ...eplace If not drafting may cause pilot outage or sooting Use a heat resistant sealant Do not seal chimney flue damper INSTALLATION WARNING Never install the heater in a bedroom or bathroom unless inst...

Страница 9: ...4 Minimum Clearance for Combustible to Wall Minimum 16 from Side Wall Example INSTALLATION Continued NOTICE Manual control heaters may be used as a vented product If so you must always run heater with...

Страница 10: ...nd the top of the fireplace opening as shown in Figure 6 Determining Minimum Mantel Clearance When Using a Hood If minimum clearances in Figure 6 page 10 are not met you must have a hood When using a...

Страница 11: ...vented mode 1 The fireplace does not meet the clear ance to combustibles requirements for vent free operation 2 State or local codes do not permit vent free operation 3 You prefer vented operation If...

Страница 12: ...ealant resistant to propane LP gas not provided electric drill with 3 16 drill bit flathead screwdriver 1 Apply pipe joint sealant lightly to male threads of the fitting to be threaded into gas regula...

Страница 13: ...incoming gas pressure You must reduce incoming gas pressure to between 11 and 14 of water If you do not reduce incoming gas pressure heater regulator damage could occur Install external regulator wit...

Страница 14: ...Cap off open end of gas pipe where equip ment shutoff valve was connected 3 Pressurize supply piping system by either opening propane LP supply tank valve for propane LP gas or opening main gas valve...

Страница 15: ...e log installation instructions in this manual Flames contact ing log will create soot MODELS LVS18 VO AND LVS24 VO It is very important to install these logs exactly as instructed Do not modify logs...

Страница 16: ...er log as shown in Left Crossover Log Figure 19 Installing Left Crossover Log Figure 20 Installing Center Crossover Log Center Crossover Log Figure 21 Installing Left Crossover Log Right Crossover Log...

Страница 17: ...FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not fol low these instructions exactly a fire or explosion may result causing property damage per sonal injury or loss of life A This appliance h...

Страница 18: ...in for 30 sec onds after lighting pilot After 30 seconds release control knob Note If pilot goes out repeat steps 3 through 7 If control knob does not pop out when released contact a qualified servic...

Страница 19: ...shut down If pilot flame pattern is incorrect as shown in Figure 25 turn heater off see To Turn Off Gas to Ap pliance page 19 see Troubleshooting page 22 Note The pilot flame on natural gas units will...

Страница 20: ...ifice holder located at the end of the burner tube again Remove any large particles of dust dirt lint or pet hair with a soft cloth or vacuum cleaner nozzle Figure 26 Orifice Holder On Outlet Burner T...

Страница 21: ...sition 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct OBSERVED PROBLEM When control knob is pressed in and turn...

Страница 22: ...atural or propane LP gas company 1 Contact local natural or propane LP gas company 2 Clean burner see Cleaning and Maintenance page 20 or replace burner orifice 1 Clean burner see Cleaning and Mainten...

Страница 23: ...perate burner until air is removed from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum instal lation clearances see page 8 4 Clean burner see Cleaning and Main...

Страница 24: ...leaks see Checking Gas Con nections page 14 1 Open window and or door for ventilation 2 Contact local natural or propane LP gas company 3 Clean ODS pilot see Cleaning and Maintenance page 20 1 Locate...

Страница 25: ...www SuperiorFireplaces US com 126842 01A 25 PARTS VARIABLE MANUALLY CONTROLLED BURNER SYSTEMS VS1824NM AND VS1824PM 15 3 14 16 11 10 4 2 12 8 5 14 13 7 9 1 15 15...

Страница 26: ...1 099415 24 Gas Regulator LP 1 8 122142 01 Manual Valve with Ignitor NG 1 122142 02 Manual Valve with Ignitor LP 1 9 122141 01 Manual Valve Outlet Tube 1 10 122146 02 Natural Gas Plate 1 11 107186 05...

Страница 27: ...8 02 Rear Log 1 124519 02 Rear Log 1 3 124518 03 Left Crossover Log 1 124519 03 Left Crossover Log 1 4 124518 04 Center Crossover Log 1 124519 04 Center Crossover Log 1 5 124518 05 Right Crossover Log...

Страница 28: ...s Pressure in of water Maximum 14 W C Minimum 11 W C Shipping Weight 27 lbs SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition heater will not produc...

Страница 29: ...HEARTH PRODUCTS at 1 800 655 2008 for informa tion You can also write to the address listed on the back page of this manual FLOOR MEDIA KIT FM100 For all models Includes lava rock burner embers and bu...

Страница 30: ...ll produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product...

Страница 31: ...IS WARRANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ________________...

Страница 32: ...126842 01 Rev A 01 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126842 01...

Отзывы: