background image

9

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Facing and 

Mantel

Side View

Facing and Mantel Clearances

Note: Hearth protection to be min. 3/8” (10mm) thick non-combustible 
or equivalent, with a k factor of .84.

INSERT LEVELING

At each front and rear corner of the insert is an adjustable leg provided 
to level the insert should the hearth of the fireplace be uneven. To adjust 
the legs, loosen the two 5/32" allen head screws, move the leg to the 
desired height, and then tighten the screws. Repeat these steps for each 
adjusting leg.

G

13”(330mm)

10”(254mm)

0”(0mm)

H

0”(0mm)

2”(21mm)

4”(102mm)

E

H

F

G

J

CL

MANTEL

TRIM

Mantel

Trim

Hearth / Floor Protection

MINIMUM CLEARANCES TO COMBUSTIBLES

Minimum clearances include any projections such as shelves, window 
sills, mantels, spacers/standoffs or surfaces to combustible construction 
etc. above the appliance. Paint or lacquer used to finish the mantel 
must be heat resistant in order to avoid discoloration.

The letters below, E through J, correspond to 

Figure 5

 showing minimum 

clearances required from the appliance to combustibles and the minimum 
projection of the hearth extension.

E  =  31-1/2" (800mm) from Top Facing to Bottom of Insert

F  =  25-1/2”  (648mm)  from  Center  of  Glass  to  Side  Facing  or  Side 

Wall

J  =  39” (991mm) from 10.5” (267mm) Mantel to Bottom of Insert

HEARTH PROTECTION

G =   Minimum Hearth Protection from Front of Insert*

H =  Vertical Distance from Insert Bottom to Combustible Material.

3"/76mm

3"/76mm

3"/76mm

1-1/2”

38mm

31-1/2”

800mm

33-1/2”

851mm

36-1/2”

927mm

39-1/2”

1003mm

Clearances

Figure 4

Figure 5

Содержание SDVI and operation

Страница 1: ...ment o vous trouvez Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournis seur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des inc...

Страница 2: ...ibles 9 Insert Leveling 9 Installation 10 12 Venting Installation 10 Zero Clearance Fireplace Installation 11 Log Set Installation 11 Surround Panels Installation 12 Face Installation 12 Gas Line Inst...

Страница 3: ...ler service agency or the gas supplier WARNING Failure to comply with these installation instructions will result in an improperly installed and operating appliance voiding its warranty Any change to...

Страница 4: ...not be connected to a chimney or flue serving a separate solid fuel burning appliance These appliances are vented gas appliances Do not burn wood or other material in these appliances This appliance i...

Страница 5: ...uel Gas Code and local zoning and code authorities for details on installation requirements Mobile home installations must conform with the Mobile Home Con struction and Safety Standard Title 24 CFR P...

Страница 6: ...ess than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS NEW YORK CITY NEW YORK MEA Certification Gas appliances must be tes...

Страница 7: ...y Packaging List 1 Insert Body with Burner Cassette 1 Log Set 1 Bag of Embers 1 Fasteners 6 slotted 1 4 truss screws 6 speed nuts 9 spring clips 3 plastic adhesive wire restraints 1 Installation and O...

Страница 8: ...wood or synthetic logs Have the chimney and all inside surfaces of the fire place brushed and vacuumed so that no soot embers or loose combustion deposits can be drawnintotheheatcirculationblowerandbl...

Страница 9: ...TO COMBUSTIBLES Minimum clearances include any projections such as shelves window sills mantels spacers standoffsorsurfacestocombustibleconstruction etc above the appliance Paint or lacquer used to fi...

Страница 10: ...f an odor during the first hour of operation Venting Installation Your Superior gas insert must be vented to the outside in accordance with the current edition of the National Fuel Gas Code ANSI Z223...

Страница 11: ...iqu ne comporte pas d orifices d amen e du gaz un orifice d au plus 37 5 mm 1 5 po peut tre pratiqu selon les r gles de l art dans la partie inf rieure des parois ou au fond de la chambre de combustio...

Страница 12: ...ets on the surround brackets per instructions provided in decorative face kit C in Figure 12 Figure 12 A B C Spring Handle Latches Door Mounting Plates 4 Fasten top surround panel with the remaining t...

Страница 13: ...ck the pressure Again close the tap gently but securely after completing the check Check the taps for gas leaks with a gas leak test solution retighten if necessary If the pressure is not sufficient m...

Страница 14: ...ILLUSTRATIONS ARE NOT TO SCALE Moving shutter bracket to the right will open shutter to the left will close shutter Figure 14 Figure 15 SHUTTER ADJUSTMENT DETAIL See Detail Shutter Adjustment Shutter...

Страница 15: ...ermostat mural voir Figure B et le cas ch ant sur le bo tier delat l commande FigureC Pouracheverl instal lationcorrectedecefoyer proc dezcommesuitavec les tiquettesadh sivesenlangues trang resfournie...

Страница 16: ...quipped with a piezo ignition device to light the pilot When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell around the appliance area for gas Be sure to smell next to the...

Страница 17: ...aches operating temperature TO TURN OFF GAS TO APPLIANCE 1 Turn off the ON OFF rocker switch and or thermostat if installed to its lowest setting 2 Turn off electric power to the appliance if service...

Страница 18: ...he gas valve and orifice may make a rushing or whistling noise If this noise is objectionable it can be reduced by turning down the flame Turning down the flame can reduce total heat output by more th...

Страница 19: ...ches to the insert for example a rocker switch and a wall thermostat Additional switches may affect the system resistance and increase the chance of the burner not igniting Follow the instructions inc...

Страница 20: ...EVER ADJUST THE PILOT untilafterthegaspressurehasbeencheckedandthesupplylineshave been completely bled this may take an hour or more when bleeding through the pilot All pilots are checked and burned a...

Страница 21: ...lable from your Lennox Hearth Products dealer Do not use substitute parts or materials The glass is neo ceramic and alterna tive types must not be used NOTE BE CAREFUL NOT TO SPRAY COMMERCIAL GLASS CL...

Страница 22: ...wer and then lift the panel with the blower attached out of the firebox To reinstall the blower repeat these steps in the reverse order Figure 21 Blower Wiring Schematic Green Ground Black Hot From Po...

Страница 23: ...f pilot lights turn off pilot and trigger the igniter again If pilot lights an intermittent gas air supply may be the problem if longer purge will not light check gap between electrode and pilot shoul...

Страница 24: ...ontrol rheostat H5744 On Off Switch H6007 On Off Switch Wires H5745 Piezo Igniter H4635 Wall Thermostat Digital H5660 Power Cord ref form 506033 04 H5977 Blower Wire H5730 Speed Control Wire for rheos...

Страница 25: ...are the part numbers of the instruction sheets included in kits Face Surround Panel Kits Required Includes Black Face Surround and Black Trim Cat No Model Description H7014 SDVI A B Arched Black Face...

Страница 26: ...areil aux combustibles HOMOLOGU FOYER RADIANT PR FABRIQU AU GAZ INSERTION DE FOYER AU GAZ NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE TEST SELON LA NORME ANSI Z21 88 2005 CSA 2 33 2005 FOYER RADIANT AU...

Страница 27: ...agent de service ou un fournisseur de gaz Si vous op rez cet appareil sans qu il ne soit correctement raccord un conduit d vacuation vous pourriez risquer d tre empoisonn au monoxyde de carbone CO ce...

Страница 28: ...ur other documents for future refer ence Product reference information We recommend that you record the following important information about your appliance Please contact your LHP dealer for any ques...

Отзывы: