background image

23

SYMPTOM

PROBABLE CAUSE

CORRECTIVE ACTION

Thin black coating (soot) 

forms on the viewing 

glass, logs, or firebox

Improper log or ember 

placement

Improper air shutter 

setting

Not enough combus-

tion air

See 

Log Set Installation on Page 11

. If there is soot in one specific location, the 

rockwool below this location needs to be adjusted. This can be done by pulling embers 

forward slightly. If the flames have soot tails, the shutter will need to be opened.

If sooting continues open air shutter (see 

Air Shutter Adjustment on Pages 13 and 14

).

Check for debris obstructing air flow in valve compartment under insert or in front of 

lower venting.

Humming or whistling 

coming from insert.

Normal operating noise

Obstructed orifice 

opening

See 

Quiet Operation on Page 18

. The noise may be reduced by slightly turning down the 

flame. Turning the flame down will reduce the heat output of the insert.

If noise is excessive or is “whistling” have your gas supplier check the regulator and 

orifices and replace if necessary.

A change in flame appear-

ance or burner operation.

A change in gas pres-

sure

Improper ember place-

ment

Have your gas supplier check for correct gas pressure (7" W.C. / po. C.E. [1.74 kPa] natu-

ral gas; 11" W.C. / po. C.E. [2.74 kPa] LP gas). 

NOTE:  NEVER BLOCK OR OBSTRUCT AIR 

INTAKE OR OUTLET VENTS.

See 

Log Set Installation on Page 11.

Spark igniter will not light 

pilot after repeated tries.

No gas supplied to unit 

or air in line

Defective igniter (no 

spark at electrode)

Defective or misaligned 

electrode at pilot (spark 

at electrode)

Check gas supply. To purge, hold in gas cock on valve for 1-2 minutes and try again.

Check for spark at electrode and pilot, if no spark and electrode wire is properly con-

nected, replace igniter and igniter wire.

Using a match, light pilot. If pilot lights, turn off pilot and trigger the igniter again. If pilot 

lights, an intermittent gas/air supply may be the problem, if longer purge will not light 

- check gap between electrode and pilot - should be 1/8 inch (3 mm) to have a strong 

spark. If OK, replace pilot.

Pilot will not stay lit after 

carefully following lighting 

instructions.

Low gas inlet pressure

Defective thermopile

Defective automatic 

valve operator

Check inlet pressure and adjust pilot if necessary.

Be sure wire connections from thermopile are tight at gas valve terminals.

Either rocker switch or thermostat wires may be grounded. Remove wires from valve 

terminals. If pilot stays lit, trace switch wiring for a ground. May be grounded to insert or 

gas supply.

Check open circuit millivolt output of thermopile. Reading should be greater than 325mV. 

Also check thermopile wire for kinks that can cause loss of mV. Replace faulty thermopile 

if wire is okay and reading is less than 325mV.

Turn valve knob to “ON” and thermostat (if installed) to 90º. Millivolt meter should read 

greater than 100 mV. If reading is OK and burner does not turn on, replace gas valve 

(qualified service technician only).

Main burner will not burn. Pilot has gone out

Rocker switch, thermo-

stat, or wires defective

Thermopile may not be 

generating sufficient 

millivolts

See 

Lighting Instructions.

Disconnect rocker switch and thermostat wires at terminals 1 and 3 on valve. Jumper 

across from 1 to 3 with pilot lit. If burner comes on either rocker switch, thermostat, or 

wiring is not functioning.

Check thermopile with millivolt meter (see 

Maintenance and Servicing

), recheck symp-

tom #2.

TROUBLESHOOTING

NOTE:  When troubleshooting the gas control system, be sure the external gas shut off valve, located at the gas supply inlet is in 

the “ON” position.
IMPORTANT:  Call your gas supplier or plumber for additional help with any gas control problem.  Valve system troubleshooting 

should only be accomplished by a qualified service technician.

Содержание SDVI and operation

Страница 1: ...ment o vous trouvez Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournis seur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des inc...

Страница 2: ...ibles 9 Insert Leveling 9 Installation 10 12 Venting Installation 10 Zero Clearance Fireplace Installation 11 Log Set Installation 11 Surround Panels Installation 12 Face Installation 12 Gas Line Inst...

Страница 3: ...ler service agency or the gas supplier WARNING Failure to comply with these installation instructions will result in an improperly installed and operating appliance voiding its warranty Any change to...

Страница 4: ...not be connected to a chimney or flue serving a separate solid fuel burning appliance These appliances are vented gas appliances Do not burn wood or other material in these appliances This appliance i...

Страница 5: ...uel Gas Code and local zoning and code authorities for details on installation requirements Mobile home installations must conform with the Mobile Home Con struction and Safety Standard Title 24 CFR P...

Страница 6: ...ess than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS NEW YORK CITY NEW YORK MEA Certification Gas appliances must be tes...

Страница 7: ...y Packaging List 1 Insert Body with Burner Cassette 1 Log Set 1 Bag of Embers 1 Fasteners 6 slotted 1 4 truss screws 6 speed nuts 9 spring clips 3 plastic adhesive wire restraints 1 Installation and O...

Страница 8: ...wood or synthetic logs Have the chimney and all inside surfaces of the fire place brushed and vacuumed so that no soot embers or loose combustion deposits can be drawnintotheheatcirculationblowerandbl...

Страница 9: ...TO COMBUSTIBLES Minimum clearances include any projections such as shelves window sills mantels spacers standoffsorsurfacestocombustibleconstruction etc above the appliance Paint or lacquer used to fi...

Страница 10: ...f an odor during the first hour of operation Venting Installation Your Superior gas insert must be vented to the outside in accordance with the current edition of the National Fuel Gas Code ANSI Z223...

Страница 11: ...iqu ne comporte pas d orifices d amen e du gaz un orifice d au plus 37 5 mm 1 5 po peut tre pratiqu selon les r gles de l art dans la partie inf rieure des parois ou au fond de la chambre de combustio...

Страница 12: ...ets on the surround brackets per instructions provided in decorative face kit C in Figure 12 Figure 12 A B C Spring Handle Latches Door Mounting Plates 4 Fasten top surround panel with the remaining t...

Страница 13: ...ck the pressure Again close the tap gently but securely after completing the check Check the taps for gas leaks with a gas leak test solution retighten if necessary If the pressure is not sufficient m...

Страница 14: ...ILLUSTRATIONS ARE NOT TO SCALE Moving shutter bracket to the right will open shutter to the left will close shutter Figure 14 Figure 15 SHUTTER ADJUSTMENT DETAIL See Detail Shutter Adjustment Shutter...

Страница 15: ...ermostat mural voir Figure B et le cas ch ant sur le bo tier delat l commande FigureC Pouracheverl instal lationcorrectedecefoyer proc dezcommesuitavec les tiquettesadh sivesenlangues trang resfournie...

Страница 16: ...quipped with a piezo ignition device to light the pilot When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell around the appliance area for gas Be sure to smell next to the...

Страница 17: ...aches operating temperature TO TURN OFF GAS TO APPLIANCE 1 Turn off the ON OFF rocker switch and or thermostat if installed to its lowest setting 2 Turn off electric power to the appliance if service...

Страница 18: ...he gas valve and orifice may make a rushing or whistling noise If this noise is objectionable it can be reduced by turning down the flame Turning down the flame can reduce total heat output by more th...

Страница 19: ...ches to the insert for example a rocker switch and a wall thermostat Additional switches may affect the system resistance and increase the chance of the burner not igniting Follow the instructions inc...

Страница 20: ...EVER ADJUST THE PILOT untilafterthegaspressurehasbeencheckedandthesupplylineshave been completely bled this may take an hour or more when bleeding through the pilot All pilots are checked and burned a...

Страница 21: ...lable from your Lennox Hearth Products dealer Do not use substitute parts or materials The glass is neo ceramic and alterna tive types must not be used NOTE BE CAREFUL NOT TO SPRAY COMMERCIAL GLASS CL...

Страница 22: ...wer and then lift the panel with the blower attached out of the firebox To reinstall the blower repeat these steps in the reverse order Figure 21 Blower Wiring Schematic Green Ground Black Hot From Po...

Страница 23: ...f pilot lights turn off pilot and trigger the igniter again If pilot lights an intermittent gas air supply may be the problem if longer purge will not light check gap between electrode and pilot shoul...

Страница 24: ...ontrol rheostat H5744 On Off Switch H6007 On Off Switch Wires H5745 Piezo Igniter H4635 Wall Thermostat Digital H5660 Power Cord ref form 506033 04 H5977 Blower Wire H5730 Speed Control Wire for rheos...

Страница 25: ...are the part numbers of the instruction sheets included in kits Face Surround Panel Kits Required Includes Black Face Surround and Black Trim Cat No Model Description H7014 SDVI A B Arched Black Face...

Страница 26: ...areil aux combustibles HOMOLOGU FOYER RADIANT PR FABRIQU AU GAZ INSERTION DE FOYER AU GAZ NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE TEST SELON LA NORME ANSI Z21 88 2005 CSA 2 33 2005 FOYER RADIANT AU...

Страница 27: ...agent de service ou un fournisseur de gaz Si vous op rez cet appareil sans qu il ne soit correctement raccord un conduit d vacuation vous pourriez risquer d tre empoisonn au monoxyde de carbone CO ce...

Страница 28: ...ur other documents for future refer ence Product reference information We recommend that you record the following important information about your appliance Please contact your LHP dealer for any ques...

Отзывы: