Operating Instructions

Pre-Lighting Checklist

Be  sure  to  check  these  items  before  the  initial  lighting  of  the 
insert:

The insert gas label corresponds to the gas supply available 
- that is "natural gas" for natural gas or "LP gas" for LP gas.

Gas pressure has been checked carefully - see 

Page 13

.

c  

All gas fittings have been checked for leaks.

c  

All clearances to combustibles have been met-see 

Page 9

.

c  

All combustible materials have been removed from the area in 

front of the insert.

c  

All vented areas of the insert face are unobstructed.

c  

House is ventilated to clear initial paint curing odors - see 

Page 

18

.

c  

All packaging materials have been removed from the firebox.

c  

While insert  is  cool,  fingerprints  or  other  marks  have  been 

cleaned from any gold or nickel surfaces with denatured alcohol 
and a soft cloth. Marks left on these surfaces may become etched 
into the finish if not removed prior to burning the unit.

c  

Log set have been installed.

c  

The glass door is in place and is properly sealed.

Lighting Instructions

The following is a copy of the operating and lighting instructions 
found with each insert:

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING:  IF YOU DO NOT FOLLOW THESE INSTRUCTIONS 
EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROP-
ERTY DAMAGE, INJURY, OR LOSS OF LIFE.

CAUTION:  HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP 
CHILDREN, FURNITURE, GASOLINE, AND OTHER LIQUIDS WITH 
FLAMMABLE VAPORS AWAY. NEVER OPERATE UNIT WITH GLASS 
OFF OR ATTEMPT TO REMOVE THE GLASS WHILE HOT.

A. This appliance is equipped with a piezo ignition device to light 

the  pilot.  When  lighting  the  pilot,  follow  these  instructions 
exactly.

B.

 BEFORE LIGHTING,

 smell around the appliance area for gas. 

Be sure to smell next to the floor, because some gas is heavier 
than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

DO NOT 

try to light the appliance. 

DO NOT

 touch any electric switch,  

DO NOT

 use any phone  in the building. Immediately call your 

gas supplier from a neighbor's phone. Follow the gas supplier's 
instructions. If you cannot reach your gas supplier, call the fire 
department.

C. Use only your hand to push in or turn the gas control knob. 

Never use any tool. If the knob will not push in or turn by hand, 
don't try to repair it, call a qualified service technician. Force or 
attempted repair may result in a fire or explosion.

D. 

DO NOT

 use this appliance if any part has been under water. 

Immediately call a qualified service technician to inspect the 
appliance and to replace any part of the control system and any 
gas control which has been under water.

OPERATING INSTRUCTIONS

CAUTION: YOUR SUPERIOR™ GAS INSERT MUST ALWAYS BE 
OPERATED WITH GLASS IN PLACE.

STOP!! Read the safety information above before proceeding.

1. Open the lower door. Make sure gas supply shut-off cocks are 

open and ON/OFF rocker switch is "OFF." If equipped with a 
thermostat, set it to the lowest setting.

2. Turn off all electrical power to the appliance.
3. Push in gas cock dial slightly and turn clockwise               to 

"OFF."

 

Note: 

 Dial cannot be turned from "PILOT" to "OFF" unless dial 

is pushed in slightly. Do not force.

4. Wait five minutes to clear out any gas. Then smell for gas, 

including near the floor. If you smell gas, STOP! Follow "B" 
above. If you don't smell gas continue.

Содержание SDVI and operation

Страница 1: ...ment o vous trouvez Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournis seur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des inc...

Страница 2: ...ibles 9 Insert Leveling 9 Installation 10 12 Venting Installation 10 Zero Clearance Fireplace Installation 11 Log Set Installation 11 Surround Panels Installation 12 Face Installation 12 Gas Line Inst...

Страница 3: ...ler service agency or the gas supplier WARNING Failure to comply with these installation instructions will result in an improperly installed and operating appliance voiding its warranty Any change to...

Страница 4: ...not be connected to a chimney or flue serving a separate solid fuel burning appliance These appliances are vented gas appliances Do not burn wood or other material in these appliances This appliance i...

Страница 5: ...uel Gas Code and local zoning and code authorities for details on installation requirements Mobile home installations must conform with the Mobile Home Con struction and Safety Standard Title 24 CFR P...

Страница 6: ...ess than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS NEW YORK CITY NEW YORK MEA Certification Gas appliances must be tes...

Страница 7: ...y Packaging List 1 Insert Body with Burner Cassette 1 Log Set 1 Bag of Embers 1 Fasteners 6 slotted 1 4 truss screws 6 speed nuts 9 spring clips 3 plastic adhesive wire restraints 1 Installation and O...

Страница 8: ...wood or synthetic logs Have the chimney and all inside surfaces of the fire place brushed and vacuumed so that no soot embers or loose combustion deposits can be drawnintotheheatcirculationblowerandbl...

Страница 9: ...TO COMBUSTIBLES Minimum clearances include any projections such as shelves window sills mantels spacers standoffsorsurfacestocombustibleconstruction etc above the appliance Paint or lacquer used to fi...

Страница 10: ...f an odor during the first hour of operation Venting Installation Your Superior gas insert must be vented to the outside in accordance with the current edition of the National Fuel Gas Code ANSI Z223...

Страница 11: ...iqu ne comporte pas d orifices d amen e du gaz un orifice d au plus 37 5 mm 1 5 po peut tre pratiqu selon les r gles de l art dans la partie inf rieure des parois ou au fond de la chambre de combustio...

Страница 12: ...ets on the surround brackets per instructions provided in decorative face kit C in Figure 12 Figure 12 A B C Spring Handle Latches Door Mounting Plates 4 Fasten top surround panel with the remaining t...

Страница 13: ...ck the pressure Again close the tap gently but securely after completing the check Check the taps for gas leaks with a gas leak test solution retighten if necessary If the pressure is not sufficient m...

Страница 14: ...ILLUSTRATIONS ARE NOT TO SCALE Moving shutter bracket to the right will open shutter to the left will close shutter Figure 14 Figure 15 SHUTTER ADJUSTMENT DETAIL See Detail Shutter Adjustment Shutter...

Страница 15: ...ermostat mural voir Figure B et le cas ch ant sur le bo tier delat l commande FigureC Pouracheverl instal lationcorrectedecefoyer proc dezcommesuitavec les tiquettesadh sivesenlangues trang resfournie...

Страница 16: ...quipped with a piezo ignition device to light the pilot When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell around the appliance area for gas Be sure to smell next to the...

Страница 17: ...aches operating temperature TO TURN OFF GAS TO APPLIANCE 1 Turn off the ON OFF rocker switch and or thermostat if installed to its lowest setting 2 Turn off electric power to the appliance if service...

Страница 18: ...he gas valve and orifice may make a rushing or whistling noise If this noise is objectionable it can be reduced by turning down the flame Turning down the flame can reduce total heat output by more th...

Страница 19: ...ches to the insert for example a rocker switch and a wall thermostat Additional switches may affect the system resistance and increase the chance of the burner not igniting Follow the instructions inc...

Страница 20: ...EVER ADJUST THE PILOT untilafterthegaspressurehasbeencheckedandthesupplylineshave been completely bled this may take an hour or more when bleeding through the pilot All pilots are checked and burned a...

Страница 21: ...lable from your Lennox Hearth Products dealer Do not use substitute parts or materials The glass is neo ceramic and alterna tive types must not be used NOTE BE CAREFUL NOT TO SPRAY COMMERCIAL GLASS CL...

Страница 22: ...wer and then lift the panel with the blower attached out of the firebox To reinstall the blower repeat these steps in the reverse order Figure 21 Blower Wiring Schematic Green Ground Black Hot From Po...

Страница 23: ...f pilot lights turn off pilot and trigger the igniter again If pilot lights an intermittent gas air supply may be the problem if longer purge will not light check gap between electrode and pilot shoul...

Страница 24: ...ontrol rheostat H5744 On Off Switch H6007 On Off Switch Wires H5745 Piezo Igniter H4635 Wall Thermostat Digital H5660 Power Cord ref form 506033 04 H5977 Blower Wire H5730 Speed Control Wire for rheos...

Страница 25: ...are the part numbers of the instruction sheets included in kits Face Surround Panel Kits Required Includes Black Face Surround and Black Trim Cat No Model Description H7014 SDVI A B Arched Black Face...

Страница 26: ...areil aux combustibles HOMOLOGU FOYER RADIANT PR FABRIQU AU GAZ INSERTION DE FOYER AU GAZ NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE TEST SELON LA NORME ANSI Z21 88 2005 CSA 2 33 2005 FOYER RADIANT AU...

Страница 27: ...agent de service ou un fournisseur de gaz Si vous op rez cet appareil sans qu il ne soit correctement raccord un conduit d vacuation vous pourriez risquer d tre empoisonn au monoxyde de carbone CO ce...

Страница 28: ...ur other documents for future refer ence Product reference information We recommend that you record the following important information about your appliance Please contact your LHP dealer for any ques...

Отзывы: