Figure 35

 - 

Top Vent -

ONE 90 DEGREE ELBOW - ELBOW CONNECTION AT APPLIANCE

Figure 36

 - 

 

Top Vent - ONE 90 DEGREE ELBOW - 

ELBOW CONNECTION NOT DIRECTLY AT APPLIANCE

 

Figure 34 

- Rear Vent - NO ELBOWS 

See Table 12 as an aid in venting component selection for a particular 
range of exterior wall thicknesses.

See Table 12  as an aid in venting component selection 
for a particular range of exterior wall thicknesses.

Notes:
• Secure 

Vent

  components (rigid vent pipe and terminal)  are shown in 

the Figures; 

Secure Flex

 components (fl exible vent pipe and terminal) 

may also be used.

• 

Two 45 degree elbows may be used in place of one 90 degree elbow.  
The same rise to run ratios, as shown in the venting Figures for 90 
elbows,must be followed if 45 degree elbows are used. 

• 

SV4.5VF (

Secure Vent

), SF4.5VF (

Secure Flex

) fi restop/spacer must be 

used anytime vent pipe passes through a combustible fl oor or ceiling. 
SV4.5HF (

Secure Vent

), SF4.5HF (

Secure Flex

) fi restop/spacer must 

be used anytime vent pipe passes through a combustible wall.

•  It is very important that the horizontal/inclined run be maintained 

in a straight (no dips)

 and recommended to be in a slightly elevated 

plane, in a direction away from the fi replace of  1/4" rise per foot (20 
mm per meter) which is ideal, though rise per foot run ratios that are 
smaller are acceptable all the way down to at or near level.

• 

The tables show a 1(V) to 5(H) ratio up to a maximum horizontal run 
of 20 feet except for installations where an elbow is the only vertical 
vent section in the system (see 

Figure 35

).

•  AN ELBOW IS ACCEPTABLE AS 1 FOOT OF VERTICAL RISE EXCEPT 

WHERE AN ELBOW IS THE ONLY VERTICAL COMPONENT IN THE 
SYSTEM.  See Figure 35.

See Table 12  as an aid in venting component selection for a particular 
range of exterior wall thicknesses.

        

WARNING

Under no circumstances, may separate sections of 
concentric fl exible vent pipe be joined together.

HORIZONTAL VENT FIGURES/TABLES

H

H = 28 in. (711 mm) Maximum.

7 in. (178 mm)

When using Secure Flex,

use Firestop/Spacer

SF4.5HF

Wall Firestop/Spacer

(SV4.5HF)

H

Wall

Firestop/Spacer

(SV4.5HF)

V

When using Secure Flex,

use Firestop/Spacer

SF4.5HF

H

V

Wall Firestop/Spacer

(SV4.5HF)

When using Secure Flex,

use Firestop/Spacer

SF4.5VF.

Ceiling

Firestop/Spacer

(SV4.5VF)

When using Secure Flex,

use Firestop/Spacer

SF4.5HF.

Venting Components Required for Various Exterior Wall Thick-

nesses, when using Square Termination Kit (SV4.5HT-2)

Vent Components Required

Exterior Wall Thickness 

- inches (mm)

Termination Kit Only

6 to 9-1/4 (152 to 235)

Termination Kit and  6 In. Vent Section 
(SV4.5L6)

10-1/2 to 13-3/4 (267 to 349)

Termination Kit and 12 in. Vent Section 
(SV4.5L12)

16-1/2 to 19-3/4 (419 to 502)

Termination Kit & Telescopic Section (SV4.5LA
2 to 7-1/2") & 6" vent section (SV4.5L6)

11 to 19-3/4 (279 to 502)

Table 12

Example: 

 If 20 feet of (H)  hori-

zontal vent run is needed, then  
4 feet minimum of (V) vertical 
vent will be required. 

This table shows a 1(V) to 
5(H) ratio.  For every 1 foot 
of vertical, you are allowed 5 
feet of (H) horizontal run up to 
a maximum (H) horizontal run 
of 20 feet.

Table G

H Maximum 

 V Minimum

feet

(meter)

feet

(meter)

5

(1.524)

1

(0.305)

10

(3.048)

2

(0.610)

15

(4.572)

3

(0.914)

20

(6.096)

4

(1.219)

V + H = 40 feet (12.2 m) Max.

H = 20 ft. (6.096 m) Max.

Square termination 
(SV4.5HT-2) shown. 

Square termination 
(SV4.5HT-2) shown. 

Square termination 
(SV4.5HT-2) shown. 

Table F

H Maximum

V Minimum 

feet

(meter)

feet

(meter)

3

(.914)

Elbow Only

M. Install the Square Termination (SV4.5HT-2) 

Install the square termination - Fo

r the last step , from outside the 

exterior wall, slide the collars of the termination onto the adapter (the 
outer inside the outer and the inner outside the inner) until the termina-
tion seats against the exterior wall surface to which it will be attached.  
Orient the housing of the termination with the arrow pointed upwards.  
Secure the termination to the exterior wall.  

The horizontal termination 

must not be recessed into the exterior wall or siding

 by more than the 

1-1/4" (32 mm) as shown in 

Figure 33

.

Note: See Figure 33 showing wall thickness range  
when using SV4.5HT-2 termination kit only.

Содержание SDDV-35

Страница 1: ...OUR SAFETY What to do if you smell gas DO NOT light any appliance DO NOT touch any electrical switches Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone...

Страница 2: ...mponents are labeledforidentification DONOTuseanyother manufacturer s vent components with these appliances Use only the correct size venting 4 1 2 inner 7 1 2 outer These appliances comply with Natio...

Страница 3: ...eld converted Inlet Gas Supply Pressure all models Fuel Minimum Maximum Natural Gas 5 0 WC 1 24 kPa 10 5 WC 2 61 kPa Propane 11 0 WC 2 74 kPa 13 0 WC 3 23 kPa Table 4 Gas Pressure All Models Tables 4...

Страница 4: ...rizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS Inspection T...

Страница 5: ...n SeeMaintenanceinstructionsin Homeowner s Manual WARNING Carbon monoxide poisoning early signs of carbon monoxide poisoning are similar to the flu withheadaches dizzinessand or nausea If you have the...

Страница 6: ...thesearecommonlyusedforlocat ing television sets and decorative plants Be awarethatthisisaheatproducingappliance Objects placed above the unit are exposed to elevated temperatures To provide for the l...

Страница 7: ...2 1 2 64 mm or less See Figure 5 For projections exceeding 2 1 2 64 mm see Figure 6 For additional vent location restrictions refer to Figure 6 on Page 8 Figure 5 Side Elevation View Note See Figure...

Страница 8: ...15 feet above the meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly I Clearance to service regulator vent outlet 3 feet 91 cm 3 feet 91 cm J Clearanc...

Страница 9: ...inimum Distance to Unprotected Side Wall Top View of Fireplace 45 o At 14 minimum side wall clearance a combustible wall can project to any length Protected wall shown in white Inches millimeters Figu...

Страница 10: ...eld Wiring a MillivoltAppliances Theoperatingcontrol switch is factory installed b Electronic Appliances Connect 120 VAC electrical power to the appliance recep tacle Step 5 Page 25 Install blower kit...

Страница 11: ...8 1019 37 1 8 943 24 610 34 1 2 876 40 1 8 1019 27 1 2 698 26 1 2 675 13 3 4 337 G H Top View Co Axial Direct Vent Pipe Collars Top Rear Vent Flue Outlet 4 1 2 114 Combustion Air 7 1 2 190 275 FRAMING...

Страница 12: ...under 100 lbs if this is the only gas appliance in the dwelling Ref NPFA 58 there may be loss of pressure resulting in insufficient fuel delivery which can result in sooting severe delayed ignition o...

Страница 13: ...ve and discard the vent cover plate Reinstall and securely tighten all four cover plate screws Reinstall the lintel cover plate When the rear vent is being used from inside thefirebox removethetwoscre...

Страница 14: ...0 0 3 9 6 5 7 5 0 0 0 2 0 2 2 7 6 1 0 3 0 0 4 5 3 7 5 2 1 6 1 0 0 2 0 3 5 9 7 5 2 6 6 0 1 0 2 0 3 1 8 5 7 6 0 0 0 1 1 2 0 9 5 7 0 2 1 0 1 4 5 1 9 5 2 6 7 0 0 2 0 1 3 3 9 5 7 7 0 0 0 0 2 2 6 9 8 1 0 1...

Страница 15: ...lectinglengthcombinations Elbows areavailablein90 and45 configurations Refer to Figure 22 on Page 16 for the SV4 5E45 and SV4 5E90 elbow dimensional specifications Where required a telescopic vent sec...

Страница 16: ...t the center axis of their initial collar section to align with the required direction of the next vent run element Twist elbow sections in a clockwise direction only so as to avoid the possiblity of...

Страница 17: ...WhenusingSecureFlex useFirestop Spacer SF4 5VF Ceiling Firestop Spacer SV4 5VF Ceiling Firestop Spacer SV4 5VF Wall Firestop Spacer SV4 5HF When using Secure Flex use Firestop Spacer SF4 5VF When usin...

Страница 18: ...048 2 0 610 15 4 572 3 0 914 20 6 096 4 1 219 H H1 20 feet 6 096 m Max V V1 H H1 40 ft 12 192 m Max Table C H H1 Maximum HMaximum V Minimum feet meter feet meter feet meter 5 1 524 2 0 610 1 0 305 10...

Страница 19: ...ureVent useSV4 5VFfirestop spaceratceilingjoists whenusingSecureFlex use SF4 5VF firestop spacer If there is living spaceabovetheceilinglevel thefirestop spacer must be installed on the bottom side of...

Страница 20: ...ing of the Horizontal Square Termination SV4 5HT 2 SeeFigure13 onPage 11 for Min Distance to Base of Appliance For thicknesses greater than 10 see Table 12 I Continue installation of horizontal inclin...

Страница 21: ...ES H H 28 in 711 mm Maximum 7 in 178 mm When using Secure Flex use Firestop Spacer SF4 5HF Wall Firestop Spacer SV4 5HF H Wall Firestop Spacer SV4 5HF V When using Secure Flex use Firestop Spacer SF4...

Страница 22: ...Example If 20 feet of H H1 horizontal vent run is needed then 4 feet minimum of V vertical vent will be required This table shows a 1 V to 5 H ratio For every 1 foot of V vertical you are allowed 5 fe...

Страница 23: ...e 12 on Page 21 as an aid in venting component selection for a particular range of exte rior wall thicknesses Example If 20 feet total H H1 horizontal vent run is needed then 4 feet minimum of V verti...

Страница 24: ...inner flexible vent pipe 4 Slidetheinnerflexpipeovertheadaptercol lar Ensure the flexible vent pipe completely engages the adapter collar to a distance of 1 3 4 inches from the end and that it is free...

Страница 25: ...power must be connectedtoeitherofthesereceptaclesinorder to operate these blowers Install the blower kits according to the installation instructions provided with the kits 3 Wire the control within th...

Страница 26: ...BLACK BL BLUE R RED W WHITE G GREEN BK W BK BK BL R GROUND 24 V Transformer View A J Box Wiring when using unit mounted relay module BK W G C A V 0 2 1 Igniter Connector Leave the OFF ON switch which...

Страница 27: ...mpartment access door Removing Control Compartment Door Openthedoorby gentlyliftingitupwarduntilthe hook catches on boths sides clear the locating slots Then pull door out to remove D Turn on burner t...

Страница 28: ...ogs have locating notches which cor respond to locating brackets and holes which correspond to locating pins to help ensure that they are properly positioned Proper log placement is critical to preven...

Страница 29: ...g Installation Instructions refer to Figure 52 Carefully position the ceramic fiber logs into the firebox as shown here Logs should be placed in the order shown and per the following instructions 1 Se...

Страница 30: ...G The glass door of this appli ance must only be replaced as a complete unit as provided by themanufacturer Donotattempt to replace broken cracked or chipped glass separately WARNING Do not attempt to...

Страница 31: ...Cold Climate Insulation and Page 9 for Clearances Burner Air Shutter Adjustment Procedure CAUTION Theairshutterdoorandnearbyappliancesurfacesare hot Exercise caution to avoid injury while adjusting f...

Страница 32: ...77L76 SV4 5E45 45 Degree Elbow 5 77L77 SV4 5E90 90 Degree Elbow 3 4 5 6 7 10 1 8 9 11 INSTALLATION ACCESSORIES The following flashings come packaged with a storm collar 6 77L78 SV4 5F Flat Roof Flashi...

Страница 33: ...12 pack 23 91L66 SF GC4 6 Gear Clamp 4 5 in 114 mm for flex 6 pieces 23 91L67 SF GC7 6 Gear Clamp 7 5 in 190 5 mm for flex 6 pieces 24 99L02 SV4 5HRK14 Horizontal Riser Kit 14 24 99L03 SV4 5HRK36 Hor...

Страница 34: ...ed exactly a fire explosion or produc tion of carbon monoxide may result causing property damage personal injury or loss of life The installation is not proper and complete until the operation of the...

Страница 35: ...rtoFigure59 andremovethepilot hood assembly to access the hexed pilot orifice Remove and replace the orifice with the one provided with the kit Pilot for SIT Millivolt Gas Valve Figure 59 Pilot Orific...

Страница 36: ...move the orifice from the manifold and replace it with the one provided in the kit See Table 14 for orifice sizes fornaturalandpropanemodels Figure 61 illustrates the orifice b Retrievetheburnerandhol...

Отзывы: