SuperiorFireplaces.us.com
900855-00_B
8
FIREPLACE INSTALLATION
Continued
A
G
Inside Chase
Back Wall of Chase/Enclosure
Including Finising Materials if any
Rough Framing Face
(Unfinished Shown)
AK4
Combustion
Air Kit
AK-4 Combustion
Air Kit
G
A
J
Outside Chase
Back Wall of Chase/Enclosure
Including Finishing Materials
if any
Rough Framing Face
(Unfinished Shown)
Header
B
A
A
E
F
D
C
K
Back Wall of Chase/Enclosure
Including Finishing Materials
if any
Rough
Framing Face
(Unfinished Shown)
Corner Installation
AK4 Combustion
Air Kit
Figure 6 - Corner Installation
Figure 5 - Inside Chase
Figure 7 - Outside Chase
Figure 4 - Fireplace Framing
Fireplace Opening Width
38
43
A
49-1/4"
(1251 mm)
54"
(1372 mm)
B
50-7/8"
(1293 mm)
50-7/8"
(1293 mm)
C
26-1/4"
(667 mm)
31"
(787 mm)
D
13-1/8"
(334 mm)
15-1/2"
(394 mm)
E
77-1/4"
(1962 mm)
82"
(2083 mm)
F
38-5/8"
(981 mm)
41"
(1041 mm)
G
26-1/4"
(667 mm)
26-1/4"
(667 mm)
J
11"
(279 mm)
11"
(279 mm)
K
54-5/8"
(1388 mm)
58"
(1473 mm)
Note:
All framing dimensions calculated for 1/2" dry wall at the fireplace
face. If sheathing the chase or finishing with other thickness materials,
calculations will need to be made.
FRAMING SPECIFICATIONS