background image

27

Printed in U.S.A. © 2013  Innovative Hearth Products

P/N 900224-00, Rev. B  02/2018

Innovative Hearth Products

1769 East Lawrence Street • Russellville, AL 35654

Innovative Hearth Products

Superior

®

 Brand Wood-Burning Fireplace

20 Year Limited Warranty

THE WARRANTY

Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior

®

 Brand wood burning fireplace ("Product") to be free from defects in materials and 

workmanship at the time of manufacture. The Product body, firebox and ceramic glass carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty 

against thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the 20 Year Limited 

Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or replacement 

is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also pay IHP prevailing 

labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to five years. THERE ARE EXCLUSIONS AND LIMITATIONS to this 

20 Year Limited Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of purchase. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six 

months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the 

date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This 20 Year Limited Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed instruc-

tions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.
This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 

provided. The Product body and firebox carry the 20 Year Limited Warranty from the date of installation. Vent components, trim components, paint and applied stains are 

excluded from this 20 Year Limited Warranty. The following do not carry a 20 Year Limited Warranty but are warranted as follows:

Air tubes, baffles and brick retainers – Repair or replacement for one year from the date of installation

Cast iron parts – Replacement for one year from date of installation

Catalyst – Carries a separate warranty. Refer to the warranty certificate provided for that part

Electrical components – Repair or replacement for one year from the date of installation

Fireplace screens, refractory and side shields (metal or refractory) – Repair or replacement for two years from date of installation. Excludes hairline cracks.

Fuel grates –These parts are considered consumable accessories and therefore are not warranted, with the exception of defects in material or workmanship which 

are covered for 90 days from the date of installation

Gaskets – Replacement for one year from date of installation

Gold & nickel plating – Replacement for two years from date of installation. Excludes tarnishing

Optional glass doors – Repair or replacement for 90 days from the date of installation

Refractory & screens – Replacement for two years from date of installation. Excludes hairline cracks

Removable air tubes – Repair or replacement for seven years from date of installation. IHP prevailing labor rates for years one through five.

Labor coverage – Prevailing IHP labor rates apply for the warranty period of the component.

Parts not otherwise listed carry a 90 day warranty from the date of installation.
Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.
IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or 

unauthorized alteration or repair of the Product affecting its stability or performance. (The Product must be subject to normal use with approved fuels listed in the Operation 

Manual provided with the product. This includes burning such fireplace fuels as wood and natural or propane gas. Fuel products with abnormal burning characteristics, 

including but not limited to fuel such as driftwood, coal or plywood and wood products using a binder may burn at excessive temperatures and may cause damage to the 

Product or may cause it to function improperly.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with 

the Product; (d) damages, repairs or inefficiency resulting from faulty installation or application of the Product.
Coverage of this 20 Year Limited Warranty is conditional upon use of an adequate fuel grate on factory-built fireplaces only, when applicable.

IHP is not responsible for inadequate fireplace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction condi-

tions which may generate negative air pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for smoking conditions caused by 

inadequate chimney height, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions. Certain IHP Products are listed for use with 

Security Chimneys International, Ltd. or IHP chimney systems only. Use of chimney components other than that specified in the Product manual will void the Product warranty.
This 20 Year Limited Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction which are not 

manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to any 

malfunction or defect in equipment are not covered by this 20 Year Limited Warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking 

IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, or 

in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.
In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or after 

replacement or repair, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a particular 

use or purpose, and there is no implied condition of fitness for a particular use or purpose.
IHP makes no expressed warranties except as stated in this 20 Year Limited Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.
No one is authorized to change this 20 Year Limited Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 

do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this 20 Year 

Limited Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this 20 Year Limited Warranty and to  decide, in its sole discretion, upon the method of settlement.
To receive the benefits and advantages described in this 20 Year Limited Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP.
Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. IHP shall in no event be responsible for any warranty work done by a contrac-

tor that is not approved without first obtaining IHP's prior written consent.

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/

distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the IHP 

Warranty Department at 1769 East Lawrence Street; Russellville, AL 35654 or visit our website at WWW.SUPERIORFIREPLACES.US.COM.

Содержание WCT6820WS

Страница 1: ...uctions This installation manual will enable you to obtain a safe efficient and dependable installation of your fireplace system Please read and understand these instructions before beginning your installation Do not alter or modify the fireplace or its components under any cir cumstances Any modification or alteration of the fireplace system including but not limited to the fireplace chimney comp...

Страница 2: ...ey lengths Elbows where necessary Associated components as per these installation instructions 6 diameter chimney Canada Models ASHT S2100 manufacture by Security Chimneys or DuraTech Canada DTC manufactured by DuraVent only including Chimney lengths Elbows where necessary Associated components as per these installation instructions instructions provided by the venting manufacturer Decorative Door...

Страница 3: ...r inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air WARNING Neither the manufacturer nor the seller warrants smoke free operation nor are we respon sible for inadequate system draft caused by mechanical systems general construction conditions inadequate chimney heights adverse wind conditions and or unusual environmental factors or conditions ...

Страница 4: ... primary air and air boost controls fully openedduring10to20minutesafterreloading depending on the heat and on the moisture content of the wood Onceyouhavereachedthedesiredtemperature the air boost can be closed and the primary air set to a medium setting You know you have reached the desired temperature when closing the primary air control you can see a flame at the top of the firebox The benefit...

Страница 5: ...ommended Carbon Monoxide Poisoning Early signs of carbonmonoxidepoisoningaresimilartotheflu withheadaches dizzinessand ornausea Ifyou have these signs obtain fresh air immediately Somepeoplearemoreaffectedbycarbonmon oxide than others including pregnant women people with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes It is against federal regulatio...

Страница 6: ... The use of a firewood moisture meter is rec ommended to ensure the firewood contains less than 20 moisture Seasoning Guide Softwoods 6 months to 18 months Hardwoods 12 months to 24 months Logsthatare5 diameteracrossorlargershould be split in half three pieces if over 8 inches and four pieces when over a foot across If a tree has been dead for 2 4 years it still needs to be cut split and seasoned ...

Страница 7: ...lace facade An Allen key 1 8 not supplied will be necessary for this adjustment Checking Door Seal A one inch strip of paper may be used to perform a test of the integrity of the door seal Close the door on the paper in at least eight points It is normal to feel only a slight amount of friction The door gasket does not need to be tight in all areas since a small amount of leakage is not hazardous ...

Страница 8: ...the entire width of the fireplace The combustible floor in front of the fireplace must be covered with a non combustible ma terial tile marble stone etc See Figure 9 COLD CLIMATE INSTALLATIONS Climates where temperatures will fall below 32 F 0 C The heating performance of the appliance will vary depending upon the level of insulation housedesign howtheapplianceisoperated etc If this fireplace is b...

Страница 9: ...box and glass are maintained at hot temperatures see RefuelingForBestPerformance Tocleanthe glass there are a number of specially designed cleaners YourauthorizedIHPdealercanrecom mend a suitable cleaner which is available in your area Regular household glass cleaners will not clean creosote Do not use abrasives such as steel pads steel wool or oven cleaner as they will scratch the glass DO NOT US...

Страница 10: ...installation instructions Product designs materials dimensions specifications colors and prices are subject to change or discontinuance without notice Allframingdimensionscalculatedfor 1 2 dry wall at the fireplace face If sheathing the chase or finishing with other thickness materials calcula tions will need to be made Thefireplacemustnotbeincontact with any insulation or loose filling material C...

Страница 11: ...lation In Outside Walls Of Chase Solid Continuous Surface Outside Base Insulation Thermal Barrier 8 Level 7 2 1 m Min 6 8 2 m Min 8 2 4 m Level 42 1067mm 2 x 3 Min 51mm x 76mm Rock Board or Other Noncombustible Facing Drywall NOTE It is recommended that the chase walls and floor be insulated in the same manner using the same insulation as the rest of the building below the attic SEE NOTE Mantel an...

Страница 12: ...e duct is twenty 20 feet 6 1 m See note below B The air intake register must not be installed more than ten 10 feet 3050 mm above the base of the fireplace C The fresh air must come from outside the house The air intake must not draw air from the attic basement or garage D The air intake should be installed where it is not likely to be blocked by snow or exposed to extreme wind and away from autom...

Страница 13: ...and no 2 Phillips screwdriver GENERAL INFORMATION If you encounter any problems need clarification of these instructions or are not qualified to properly install this kit contact you local distribu tor or dealer Readthisinstructionsheetinitsentiretybeforebeginningtheinstallation ALL WARNINGS AND PRECAUTIONS IN THE INSTALLATION AND OPERATION MANUAL PROVIDED WITH THE APPLIANCE APPLY TO THESE INSTRUC...

Страница 14: ...11 280mm Min Duct Ring Duct Adaptor Tab It is recommended that the ducted flex kit duct system be installed in the following order 1 Plan and frame fireplace and outlet locations prior to ducted flex kit installation 2 Remove the two 8 diameter cutouts on top of the fireplace Then cut the insulation in order to obtain two 8 diameter openings and remove the insulation 3 On the duct adaptor bend the...

Страница 15: ...he outlet grill The minimum height from thebottomoftheunittothecenteroftheoutletis68 1 7m with the minimum distance from the center of outlet to the ceiling and for the center of the outlet to a side wall of 11 279mm Do not connect the hot air ducts to a central heating system Use only IHP grills and components as described in this manual Ensure that the flex insulation and sheathing do not touch ...

Страница 16: ...achieved by having the chimney supported by the supports The maximum chimney length that can be supported by the fireplace is nine 9 feet 2 75 m 6 The chimney must extend at least three 3 feet 915 mm above its point of contact with the roof and at least two 2 feet 610 mm higher than any wall roof or building within ten 10 feet 3m of it 7 If the chimney extends higher than five 5 feet 1 500 mm abov...

Страница 17: ...ber of equal size to the joist should be used Figure 26 FEMALE END MALE END BUTTON LOCK ATTACH FOR LOCK Figure 27 INSULATION SHIELD CAT NO SPIS NAIL FIRESTOP CAT NO SPFS Chimney Flue Diameter 6 A 12 7 16 B 12 7 16 Table 3 If the area above the ceiling is an attic go to step 5 2 Install SNAP PAK chimney sections start ing at the top of the appliance Leave the first section loose until the installat...

Страница 18: ...rance to combustibles AT THIS POINT TIGHTEN CLAMPS 11 Slide IHP chimney pipe into top of tee Align male and female ends Push down on pipe sec tions until locked As sections are added it will be necessary to secure them to the outside wall with bands SPWB at eight foot intervals and 2 from combustibles Wall Bands SPWB are secured to the chimney by placing band around the chimney and tightening clam...

Страница 19: ...tall the next SP chimney section through the roof See Figure 32 NOTE If your roof is already shingled be sure to slide the upper edge under the shingles to prevent leakage 3 Install a bead of caulk around the pipe at the top edge of the flash ing Wrap the storm collar around the pipe and imbed the edge in the caulk to prevent leakage around the pipe 4 Continue to install pipe sections until the pr...

Страница 20: ...dverse wind conditions etc may create a need for a taller chimney should smoking occur Additional support is required above the roof if the chimney height exceeds four 4 feet Select the proper support for your application using either a roof brace Figure 36 or a support band with guy wires Figure 37 Figure 34 IF 10 FEET OR LESS L944 FIG21 THEN BUT MUST BE AT LEAST 2 FEET NEVER LESS THAN 3 FEET Fig...

Страница 21: ...ed with a chimney adaptor suitable for use with IHP SnapPak venting In Canada the use of Security Chimneys ASHT adaptor is required Security part number 6IHP1 or 6IHP2 One inch wall Two inch wall Figure 38 Chimney Adaptor Canada only 18 460 mm 16 410 mm 18 460 mm 18 460 mm 16 410 mm CANADA ONLY CHIMNEY INSTALLATION INSTRUCTIONS USING SECURITY CHIMNEYS ASHT CANADA APPROVED VENTING SYSTEMS 6 diamete...

Страница 22: ... chimney at 30º 3 Increase the size of the hole until a 30º liner elbow can be easily slipped through 4 Slide the liner down from the top of the masonry chimney until you reach the hole level 5 Slip through the hole a 30º liner elbow and connect it to the liner 6 Add a small liner section to the other end of the liner elbow which will allow the liner to extend at least 12 measured at the top of th...

Страница 23: ...ng UZI UZI EPA Fireplace HeatFlo Convection Kit EPA Heatflo Conv Kit EPA HEATFLO KIT F3790 OPTIONAL INSTALLATION ACCESSORIES Fireplace Kits Description Cat Part No Central Forced Air Kit Accessories Central Forced Air Kit Central forced air kit including blower BISZY flex adaptor BISAF 2 clamps variable speed control VRUW thermo disk VTU fan to flexible pipe adaptor BISAVF back draft damper BISBD ...

Страница 24: ...ar PR SR2323 Gasket Kit Glass 69 1 x 5 16 steel and cast doors PR SR1823H Gasket Kit Steel Door Frame 73 5 8 dia PR SR1685D Gasket Kit Cast Door Frame 73 5 8 dia PR SR1823G Touch up Paint Aerosol Black Metallic SBMB6309 H8159 Touch up Paint Charcoal for hammered steel facade PR P6201 Coupler Outside Air connects UZI to fireplace UZIAD Coupler for AC Chimney connects ACZI to fireplace H3274 Blower ...

Страница 25: ... and Misc Chimney Components 8 length 6 Dia 6DTC 08SS 12 length 6 Dia 6DTC 12SS 18 length 6 Dia 6DTC 18SS 24 length 6 Dia 6DTC 24SS 36 length 6 Dia 6DTC 36SS 48 length 6 Dia 6DTC 48SS Adjustable Length 12 6 Dia 6DTC 12TASS 15º elbow 6 Dia 6DTC E15SS 30º elbow 6 Dia 6DTC E30SS Rain Termination Cap 6 Dia 6DTC VC Spark Arrester Screen universal spark arrester band DTC SA Wall Band DTC WSU Supports Of...

Страница 26: ...RATE THE FIREPLACE WITH DOOR FULLY OPEN OR FULLY CLOSED ONLY POUR USAGE AVEC LE BOIS SEULEMENT UN TABLIER NON COMBUSTIBLE DOIT ÊTRE INSTALLÉ À L AVANT DU FOYER DIMENSION MINIMALE DE 18 po 457 mm PAR 36 po 914 mm DE LARGE CE FOYER N EST PAS HOMOLOGUÉ POUR ÊTRE UTILISÉ AVEC UN ENSEMBLE DE BÛCHES À GAZ SANS CONDUIT D ÉVACUATION AFIN DE RÉDUIRE LES RISQUES D INCENDIE OU DE BLESSURES N INSTALLEZ PAS DE...

Страница 27: ...al use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperatures and may cause damage to the Product or may cause i...

Страница 28: ...for any questions or concerns REPLACEMENT PARTS See Page 19 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The serial numbe...

Отзывы: