FRAMING DIMENSIONS
Fireplace Opening Width
A
36-1/4”
921 mm
B
42”
1067 mm
C
30-1/8”
764 mm
D
13-1/2”
343 mm
E
77”
1956 mm
F
37-1/2”
953 mm
G
*24-1/2”
603 mm
J
53-3/4”
1365 mm
K
8”
203 mm
L
1”
25 mm
Fireplace Framing
Header
B
A
OUTSIDE CHASE
G
C
A
Back Wall of Chase/Enclosure
Including Finising Materials if any
Rough Framing Face (Unfinished Shown)
* Zero Clearance
From Back
Spacer to Wall
Corner Installation
* Total depth is 25 inches (635mm) including the
back standoff minus 1/2 inch (13mm) for drywall
to be flush with the facing.
7’
Min.
B
G
2 x 3
Mi
n.
Rough Framing Face
(dimension includes finish
material inside framing, if any)
19-5/8”
F
20-1/2”
J
E
D
9-3/4”
28-1/8”
1”
14”
10-3/8”
24”
22-5/8”
36-1/8”
36”
42”
22-1/2”
12-1/4”
3-1/4”
6-3/4
8-1/4”
17-3/4”
24”
15-1/2”
12-3/4
3-3/4
17-3/4”
Figure 11 - Framing Dimensions
Combustible materials can NOT
be used in the space directly
above the fireplace. Do not fill
the space above the fireplace
with any material (Except the
wood framing)
Notes
Diagrams, illustrations and photo-
graphs are not to scale – consult
installation instructions. Product
designs, materials, dimensions,
specifications, colors and prices are
subject to change or discontinuance
without notice.
All framing dimensions calculated for
1/2" dry wall at the fireplace face. If
sheathing the chase or finishing with
other thickness materials, calcula-
tions will need to be made.
* The fireplace must not be in contact
with any insulation or loose filling
material. Cover the insulation with
Drywall panels around the fireplace.
K
Combustion Air Kit
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
1. Combustible material must be
installed flush with the fireplace. It
may not project in front of and on
the fireplace (i.e. the steel facade of
the fireplace) (Figure 16).
2. Non-combustible materials such as
brick, stone or ceramic tile may proj-
ect in front of and onto the fireplace
facing (Figure 17).
IMPORTANT
The facade must be removable
once installed. The facade is
designed to overlap any facing
material installed on the front of
the fireplace. If thicker material
is installed, use the facade as a
template and make sure it can
be easily removed for servicing.
Facing
Plywood 1/2”
Top View
Front View
Right Side View
Left Side View
**Heatflo Vent Outlets
**
K (allow space when framing)
10