Building a Fire 

(starting and maintaining a fire)

To start a fire, place several crumpled up balls of 

newspaper in the firebox.  Place small dry pieces 

of kindling on top of the paper, criss-crossing the 

kindling so that there are air spaces in between. 

Keep the fuel far back enough so that air can 

get underneath.  Open the air controls fully and 

light the newspaper. Once the newspaper and the 

kindling is well ignited, close the door.  Once the 

kindling fire is well established, cord wood can 

be added (see 

Primary Air Combustion Control 

section for proper operation of the air controls).
The unit will burn best with 2-3 pieces of cord 

wood spaced 1 to 2 inches apart and allowing air 

to get under the fuel.  Criss-crossing or arrang-

ing the fuel so that air can get underneath, will 

help the fire to get started easily. The unit should 

be operated with the air control fully open long 

enough to get the cord wood well ignited.

COMBUSTION CONTROLS

Primary Air and Air Boost Controls

There is no flue damper in the wood burning 

fireplace.  As is common with air tight stoves, 

the combustion air control sets the flow of air 

entering the firebox.  This allows for a more 

precise control of the fire.  The combustion air 

control is located below the door on the left side.  

The main source of air (primary air) entering 

For instance, a long chimney will necessitate 

closing the damper more.  To obtain the proper 

combustion, close the damper completely, then 

open it about 1/4” to 1/2”.  Three medium size 

pieces of wood should be burning on a bed of 

hot coals. The heat output will be approximately 

30,000 BTU per hour and the loading time will 

be about every 3-4 hours.  Softwoods may be 

burned using this method but the time will be 

substantially reduced.

Slow Combustion

When the air combustion control is completely 

closed, the fireplace is in a slow combustion phase. 

If the hearth is hot enough, slow combustion will 

not extinguish the fire, but there will be a notice-

able change in the flame pattern. The flames will 

be slow and may appear dirty if the wood is too 

wet (moisture content of 20% and more). Do 

not allow the wood to burn without flame, since 

this will produce excessive creosote in the unit.

Creosote may accumulate on the glass door. 

This method of burning should be used only 

after operating the fireplace with the air control 

opened to produce a hot fire for about an hour 

or at medium pace for at least three (3) hours. 

Slow combustion can be used at night in order to 

reduce the heat output and to prolong the burn. 

The loading time will be between 6-8 hours.

REFUELING FOR BEST PERFORMANCE

The fireplace will operate best if attention is 

given to operating the unit with the damper 

fully opened after refueling in order to bring 

the firebox and the chimney system up to their 

optimum operating temperature.  Combustion 

efficiency is relative to firebox temperature. A 

temperature of 500º C (932º F)  and up, with 

a visible flame, in the upper part of the firebox 

indicates a maximum efficiency.  To obtain this 

temperature, the fireplace must be operated 

with the primary air and air boost controls fully 

opened during 10 to 20 minutes after reloading, 

depending on the heat and on the moisture 

content of the wood.  

Once you have reached the desired temperature, 

the air boost can be closed and the primary air 

set to a medium setting.  You know you have 

reached the desired temperature when, closing 

the primary air control, you can see a flame 

at the top of the firebox.  The benefit of this 

technique will be cleaner glass, less creosoting, 

greater efficiency and the most pleasing fire for 

your enjoyment. 

SMOKING – 

CAUSES AND TROUBLESHOOTING

To reduce the likelihood of smoking when open-

ing the door, set the combustion air controls to 

the left before opening the door.  Your fireplace 

has been designed and tested to provide smoke 

free operation.  Occasionally, there may be a 

small amount of smoking upon lighting the fire, 

until the chimney heats up but this should not 

continue.  If the fireplace continues to smoke 

it is probably for one of the following reasons:

the firebox can be diminished by moving the 

air combustion control from left to right. The 

primary air is fully opened when the air control 

is completely moved to the left. The air control 

device can also be used to add an extra boost of 

air especially during fire start up and reloading 

of the unit. 

Pulling the air combustion control will induce an 

air boost at the base of the fire allowing an easier 

fire start up. When the fire is well established, 

the control can be pushed in to shut down the 

air boost allowing for a longer burn time. The 

combustion air control should be in the closed 

position (primary air and air boost) when the 

fireplace is not in use.  This will minimize air 

leakage up the chimney.  The combustion air 

control should be opened before opening the 

door to minimize the possibility of back draft 

coming into the room.

Accelerated Combustion

The maximum heat output for the fireplace is 

achieved by burning with the door closed and 

the combustion air opened and pulled out.  By 

this method, the fireplace can produce up to 

55,000 BTU of heat per hour.  However, it will 

be necessary to reload with wood every one or 

two hours.  This is the least efficient method of 

burning the fireplace.

Use caution when firing with the combustion 

air control wide open.  Only burn cord wood 

in this manner.  Small dry pieces of softwood 

and construction scraps will burn very intensely 

using this method and may damage the firebox.

Medium Combustion

This is the recommended mode of operating 

the fireplace and should be the one normally 

used since it will deposit the least amount of 

creosote on the glass and in the chimney.  The 

combustion air control must be 3/4 closed and 

pushed in to close the air boost.  The precise 

setting will depend on many factors, including 

chimney length and the moisture content of 

the wood.

       WARNING 

Be careful adding wood fuel to 

the fire or handling fireplace tools 

such as shovels, tongs or pokers.

       WARNING 

The bottom refractory can be 

cracked by excessive abuse such 

as tossing heavy logs onto the 

grate or gouging with fireplace 

tools. Exercise caution when 

adding wood to your fireplace.

Figure 1

Slow

Push to Close

Air Boost

Pull  to  

Open

Air Boost

Medium

Accelerated

4

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Содержание WCT4820

Страница 1: ...hot during operation and will retain heat for a while after shutting off the appli ance Severe burns may result Carefully supervise children in the same room as appliance If small children are presen...

Страница 2: ...gths Elbows where necessary Associated components as per these installation instructions 6 diameter chimney Canada Models ASHT S2100 manufacture by Security Chimneys or DuraTech Canada DTC manufacture...

Страница 3: ...ys ensure that the air inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air WARNING Neither the manufacturer nor the seller warrants smoke free oper...

Страница 4: ...the primary air and air boost controls fully openedduring10to20minutesafterreloading depending on the heat and on the moisture content of the wood Onceyouhavereachedthedesiredtemperature the air boost...

Страница 5: ...mmended Carbon Monoxide Poisoning Early signs of carbonmonoxidepoisoningaresimilartotheflu withheadaches dizzinessand ornausea Ifyou have these signs obtain fresh air immediately Somepeoplearemoreaffe...

Страница 6: ...The use of a firewood moisture meter is rec ommended to ensure the firewood contains less than 20 moisture Seasoning Guide Softwoods 6 months to 18 months Hardwoods 12 months to 24 months Logsthatare5...

Страница 7: ...ng the hinge screws Figure 5 Figure 6 Door Installation Figure 7 Hinge Screws Gasket Adjustment Screw 1 2 3 7 6 5 4 WARNING Use only a IHP glass doors specifically designed for the WCT4820WS fireplace...

Страница 8: ...of the fireplace The combustible floor in front of the fireplace must be covered with a non combustible ma terial tile marble stone etc See Figure 9 COLD CLIMATE INSTALLATIONS Climates where temperat...

Страница 9: ...ols closed the glass will tend to get dirty unless the fuel firebox and glass are maintained at hot temperatures see RefuelingForBestPerformance Tocleanthe glass there are a number of specially design...

Страница 10: ...ion instructions Productdesigns materials dimensions specifications colors and pricesaresubjecttochangeordiscontinu ance without notice All framing dimensions calculated for 1 2 dry wall at the firepl...

Страница 11: ...t Be Used To Cover Chase Opening 8 Level 8 2 4 m Level Outside Base Insulation Thermal Barrier Solid Continuous Surface NOTE Itisrecommendedthatthechasewalls andfloorbeinsulatedinthesamemanner usingth...

Страница 12: ...e than ten 10 feet 3050 mm above the base of the fireplace C The fresh air must come from outside the house Theairintakemustnotdrawairfrom the attic basement or garage D The air intake should be insta...

Страница 13: ...Phillips screwdriver GENERAL INFORMATION If you encounter any problems need clarification of these instructions or are not qualified to properly install this kit contact you local distribu tor or dea...

Страница 14: ...Min Duct Ring Duct Adaptor Tab It is recommended that the ducted flex kit duct system be installed in the following order 1 Plan and frame fireplace and outlet locations prior to ducted flex kit insta...

Страница 15: ...grill The minimum height from thebottomoftheunittothecenteroftheoutletis68 1 7m with the minimum distance from the center of outlet to the ceiling and for the center of the outlet to a side wall of 1...

Страница 16: ...chieved by having the chimney supported by the supports The maximum chimney length that can be supported by the fireplace is nine 9 feet 2 75 m 6 The chimney must extend at least three 3 feet 915 mm a...

Страница 17: ...er of equal size to the joist should be used Figure 26 FEMALE END MALE END BUTTON LOCK ATTACH FOR LOCK Figure 27 INSULATION SHIELD CAT NO SPIS NAIL FIRESTOP CAT NO SPFS Chimney Flue Diameter 6 A 12 7...

Страница 18: ...ance to combustibles AT THIS POINT TIGHTEN CLAMPS 11 Slide IHP chimney pipe into top of tee Align male and female ends Push down on pipe sec tions until locked As sections are added it will be necessa...

Страница 19: ...all the next SP chimney section through the roof See Figure 32 NOTE If your roof is already shingled be sure to slide the upper edge under the shingles to prevent leakage 3 Install a bead of caulk aro...

Страница 20: ...verse wind conditions etc may create a need for a taller chimney should smoking occur Additional support is required above the roof if the chimney height exceeds four 4 feet Select the proper support...

Страница 21: ...d with a chimney adaptor suitable for use with IHP SnapPak venting In Canada the use of Security Chimneys ASHT adaptor is required Security part number 6IHP1 or 6IHP2 One inch wall Two inch wall Figur...

Страница 22: ...chimney at 30 3 Increase the size of the hole until a 30 liner elbow can be easily slipped through 4 Slide the liner down from the top of the masonry chimney until you reach the hole level 5 Slip thro...

Страница 23: ...90 OPTIONAL INSTALLATION ACCESSORIES Fireplace Kits Description Cat Part No Blower heat activated on off pre wired UZY5 UZY5 Blower motor speed control wall mount VRUW VRUW Central Forced Air Kit Acce...

Страница 24: ...c blower VTU Bracket secondary air tube PR SR2214 Hinge assembly fireplace and door PR SR2395UL Door handle rod and mechanism PR SR2118 Door handle and brass cap PR SR2325 Door handle brass cap POIGNE...

Страница 25: ...and Misc Chimney Components 8 length 6 Dia 6DTC 08SS 12 length 6 Dia 6DTC 12SS 18 length 6 Dia 6DTC 18SS 24 length 6 Dia 6DTC 24SS 36 length 6 Dia 6DTC 36SS 48 length 6 Dia 6DTC 48SS Adjustable Length...

Страница 26: ...NERIE TEL QUE D CRIT DANS LE MANUEL D INSTALLATION LES COMPOSANTES UTILIS ES AVEC LE FOYER DOIVENT TRE HO MOLOGU ES VOIR LA LISTE DANS LE MANUEL D INSTALLATION REMPLACER LA VITRE AVEC UN VERRE C RAMIQ...

Страница 27: ...l use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning cha...

Страница 28: ...or any questions or concerns REPLACEMENT PARTS See Page 24 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP di...

Отзывы: