background image

CLEARANCE TO COMBUSTIBLES

The following clearances meet the minimum requirements for a safe 

installation:

Side wall: 

17” (324 mm) measured from the fireplace side.

Ceiling:

  6’ 8”  (2,032 mm) measured from the base of the fireplace.

Fireplace enclosure:

 

Bottom

:  0”

Side:

   0” to standoff

Back:

   0” to standoff

Top:

 Do not fill the space above the fireplace with any material 

(Except the wood framing.  See 

Page 10, Figure 9).

Chimney:

  2” (50 mm)

Mantel: 

45”  (1143 mm) measured from the base of the fireplace.

WCT4820WS Replacement Parts

Description

Cat./Part No.

Baffle refractory (2 pieces)

PR-ISO2205

Back refractory

PR-SR2203

Right side refractory

PR-SR2204D

Left side refractory

PR-SR2204G

Bottom refractory

PR-SR2201

Front refractory, right side - ash lip

PR-SR2202D

Front refractory, left side - ash lip

PR-SR2202G

Door handle

PR-SR1787

Ceramic glass panel Contemporary

PR-SR2222

Ceramic glass panel Victorian

PR-SR2230

Secondary air tube

PR-SR2271

Cast-iron log supports (2)

PR-SR2245

Touch-up paint, aerosol, black metallic SBMB6309

H8159

Louvers, upper and lower (1)

PR-SR2218-1

Snap disc, blower 

VTU

Bracket, secondary air tube 

PR-SR2214

Hinge assembly, fireplace and door 

PR-SR2395UL

Door handle rod and mechanism

PR-SR2118

Door handle and brass cap

PR-SR2325

Door handle brass cap

POIGNE002

Gasket, door, 73” (5/8” dia.)

PR-SR1823G

Gasket, glass, 69” (5/16” dia.)

PR-SR1685D

Blower 250 CFM for central forced air kit, BISZY

BISZY

Blower variable speed control with decorative wall plate 

for (BISZY), VRUW

VRUW

Thermo-disk, on/off blower control (for BISZY), VTU

VTU

Blower to flexible pipe adaptor, BISAVF

BISAVF

Backdraft damper, BISBD

BISBD

Fireplace to Flex adaptor and 2 clamps, BISAF

BISAF

WCT4820WS Metal Fab Collar and Sleeve

F4188

REPLACEMENT PARTS LIST

SPECIFICATIONS

Cat. No.

Model

F1793

WCT4820WS

Product Reference Information

Weight

385 lbs 

Height

36”

Width

36”

Depth

24-1/2”

Firebox W x H x D - measured in front

22” x 11-3/4” x 12”

Chimney weight ASHT (6” dia)

6.25 lb per linear foot

Chimney weight AC (6” dia)

3.25 lb per linear foot

Chimney weight S2100+ (6” dia.)

10.8 lb per linear foot

Contact an IHP dealer to obtain any of these parts. Never use substitute 

materials not approved by IHP. Use of non-approved parts can result 

in poor performance and safety hazards.

Model

Emission Rate

Heat Output

EPA Estimated 

Efficiency

WCT4820WS

3.7 g/hr

10,442-27,746 btu/hr

63%

24

Содержание WCT4820

Страница 1: ...hot during operation and will retain heat for a while after shutting off the appli ance Severe burns may result Carefully supervise children in the same room as appliance If small children are presen...

Страница 2: ...gths Elbows where necessary Associated components as per these installation instructions 6 diameter chimney Canada Models ASHT S2100 manufacture by Security Chimneys or DuraTech Canada DTC manufacture...

Страница 3: ...ys ensure that the air inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air WARNING Neither the manufacturer nor the seller warrants smoke free oper...

Страница 4: ...the primary air and air boost controls fully openedduring10to20minutesafterreloading depending on the heat and on the moisture content of the wood Onceyouhavereachedthedesiredtemperature the air boost...

Страница 5: ...mmended Carbon Monoxide Poisoning Early signs of carbonmonoxidepoisoningaresimilartotheflu withheadaches dizzinessand ornausea Ifyou have these signs obtain fresh air immediately Somepeoplearemoreaffe...

Страница 6: ...The use of a firewood moisture meter is rec ommended to ensure the firewood contains less than 20 moisture Seasoning Guide Softwoods 6 months to 18 months Hardwoods 12 months to 24 months Logsthatare5...

Страница 7: ...ng the hinge screws Figure 5 Figure 6 Door Installation Figure 7 Hinge Screws Gasket Adjustment Screw 1 2 3 7 6 5 4 WARNING Use only a IHP glass doors specifically designed for the WCT4820WS fireplace...

Страница 8: ...of the fireplace The combustible floor in front of the fireplace must be covered with a non combustible ma terial tile marble stone etc See Figure 9 COLD CLIMATE INSTALLATIONS Climates where temperat...

Страница 9: ...ols closed the glass will tend to get dirty unless the fuel firebox and glass are maintained at hot temperatures see RefuelingForBestPerformance Tocleanthe glass there are a number of specially design...

Страница 10: ...ion instructions Productdesigns materials dimensions specifications colors and pricesaresubjecttochangeordiscontinu ance without notice All framing dimensions calculated for 1 2 dry wall at the firepl...

Страница 11: ...t Be Used To Cover Chase Opening 8 Level 8 2 4 m Level Outside Base Insulation Thermal Barrier Solid Continuous Surface NOTE Itisrecommendedthatthechasewalls andfloorbeinsulatedinthesamemanner usingth...

Страница 12: ...e than ten 10 feet 3050 mm above the base of the fireplace C The fresh air must come from outside the house Theairintakemustnotdrawairfrom the attic basement or garage D The air intake should be insta...

Страница 13: ...Phillips screwdriver GENERAL INFORMATION If you encounter any problems need clarification of these instructions or are not qualified to properly install this kit contact you local distribu tor or dea...

Страница 14: ...Min Duct Ring Duct Adaptor Tab It is recommended that the ducted flex kit duct system be installed in the following order 1 Plan and frame fireplace and outlet locations prior to ducted flex kit insta...

Страница 15: ...grill The minimum height from thebottomoftheunittothecenteroftheoutletis68 1 7m with the minimum distance from the center of outlet to the ceiling and for the center of the outlet to a side wall of 1...

Страница 16: ...chieved by having the chimney supported by the supports The maximum chimney length that can be supported by the fireplace is nine 9 feet 2 75 m 6 The chimney must extend at least three 3 feet 915 mm a...

Страница 17: ...er of equal size to the joist should be used Figure 26 FEMALE END MALE END BUTTON LOCK ATTACH FOR LOCK Figure 27 INSULATION SHIELD CAT NO SPIS NAIL FIRESTOP CAT NO SPFS Chimney Flue Diameter 6 A 12 7...

Страница 18: ...ance to combustibles AT THIS POINT TIGHTEN CLAMPS 11 Slide IHP chimney pipe into top of tee Align male and female ends Push down on pipe sec tions until locked As sections are added it will be necessa...

Страница 19: ...all the next SP chimney section through the roof See Figure 32 NOTE If your roof is already shingled be sure to slide the upper edge under the shingles to prevent leakage 3 Install a bead of caulk aro...

Страница 20: ...verse wind conditions etc may create a need for a taller chimney should smoking occur Additional support is required above the roof if the chimney height exceeds four 4 feet Select the proper support...

Страница 21: ...d with a chimney adaptor suitable for use with IHP SnapPak venting In Canada the use of Security Chimneys ASHT adaptor is required Security part number 6IHP1 or 6IHP2 One inch wall Two inch wall Figur...

Страница 22: ...chimney at 30 3 Increase the size of the hole until a 30 liner elbow can be easily slipped through 4 Slide the liner down from the top of the masonry chimney until you reach the hole level 5 Slip thro...

Страница 23: ...90 OPTIONAL INSTALLATION ACCESSORIES Fireplace Kits Description Cat Part No Blower heat activated on off pre wired UZY5 UZY5 Blower motor speed control wall mount VRUW VRUW Central Forced Air Kit Acce...

Страница 24: ...c blower VTU Bracket secondary air tube PR SR2214 Hinge assembly fireplace and door PR SR2395UL Door handle rod and mechanism PR SR2118 Door handle and brass cap PR SR2325 Door handle brass cap POIGNE...

Страница 25: ...and Misc Chimney Components 8 length 6 Dia 6DTC 08SS 12 length 6 Dia 6DTC 12SS 18 length 6 Dia 6DTC 18SS 24 length 6 Dia 6DTC 24SS 36 length 6 Dia 6DTC 36SS 48 length 6 Dia 6DTC 48SS Adjustable Length...

Страница 26: ...NERIE TEL QUE D CRIT DANS LE MANUEL D INSTALLATION LES COMPOSANTES UTILIS ES AVEC LE FOYER DOIVENT TRE HO MOLOGU ES VOIR LA LISTE DANS LE MANUEL D INSTALLATION REMPLACER LA VITRE AVEC UN VERRE C RAMIQ...

Страница 27: ...l use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning cha...

Страница 28: ...or any questions or concerns REPLACEMENT PARTS See Page 24 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP di...