IMPORTANT! GENERAL SAFETY 

PRECAUTIONS. READ AND 

UNDERSTAND THESE SAFETY 

RULES BEFORE YOUR FIRST FIRE.

       WARNING 

To avoid the risk of damaging 

fireplace materials and increas-

ing the risk of fire, do not use the 

fireplace to cook or warm food.

       IMPORTANT 

When burning wood, use SOLID 

NATURAL  DRY WELL-SEASONED 

WOOD ONLY.  Hardwoods are rec-

ommended (soft woods tend to burn 

very quickly).  

• DO NOT burn treated wood, 

charcoal, coal, trash, cardboard, 

driftwood, woods dipped in tar, 

Christmas tree greens, pitch, pine 

tar, creosote, chemical chimney 

cleaners, flame colorants, poly-

styrene packaging, wood prod-

ucts with synthetic binders (i.e. 

plywood).  Plywood, lumber and 

other misc. materials can produce 

abnormally high temperatures, 

sputtering and smoking fires and 

may contain hazardous chemicals 

to treat insects and fungus.

•  Burning unapproved fuels can 

produce excessive temperatures, 

beyond the design capabilities 

of the fireplace and may produce 

excess sparks or may contain 

hazardous chemicals.  Burning 

unapproved fuels can result in 

a chimney fire, a house fire, 

personal injury, death or loss of 

property.

 

       WARNING 

Never leave children unattended 

when there is a fire burning in the 

fireplace.

       WARNING 

NEVER use gasoline, gasoline-

type lantern fuel, kerosene, 

charcoal lighter fluid, naphtha, 

engine oil or similar liquids to 

start or “freshen up” a fire in this 

fireplace. Keep any flammable 

liquids a safe distance from the 

fireplace at all times. 

       WARNING 

Use care when selecting window 

treatments for windows located 

near the fireplace.  Avoid using 

combustible flowing window 

treatments such as curtains on 

nearby windows that are of suf-

ficient length to be blown in front 

of an open flame when the window 

is opened.  Keep any combustible 

furniture, materials or decorative 

pillows at least 48" (1219 mm) 

from the front fireplace opening.

       WARNING 

Never modify or alter your fireplace 

system in any way. To do so may 

create a potential fire hazard and 

void the limited warranty

, listings 

and approvals of this system.

       WARNING 

Never leave your fireplace unat-

tended while it is burning.

       WARNING 

Always ensure that the air inlet to 

the fireplace is free from debris 

and any other obstructions that 

can block the entrance of air.

       WARNING 

Neither the manufacturer nor the 

seller warrants “smoke free” 

operation nor are we respon-

sible for inadequate system draft 

caused by mechanical systems, 

general construction conditions, 

inadequate chimney heights, 

adverse wind conditions and/or 

unusual environmental factors 

or conditions beyond our control. 

       IMPORTANT 

WHEN INSTALLED IN A MOBILE OR 

MANUFACTURED HOME:

• Mobile or manufactured home 

installations must be installed in 

accordance with the requirements 

of the Department of Housing and 

Urban Development (HUD) “Mobile 

Home Construction and Safety stan-

dards” for US or Canada Mortgage 

and Housing Corporation (CMHC) 

for Canada.

• The fireplace must be fastened to 

the floor by unfolding and screwing 

the small tabs on both sides at the 

bottom of the fireplace.   

• It is necessary to have access 

openings, for inspection purpose 

only, into built-in enclosures sur-

rounding the fireplace installation.  

Such openings to require a house-

hold tool for access.

• The vapor barrier of the mobile 

home shall be as close as possible 

of the location where the chimney 

assembly penetrates the ceiling 

and roof structure with no interfer-

ence to the required clearance to 

combustible material. 

• When the mobile or manufactured 

home has a flat roof, the Attic Radia-

tion Shield  must be installed from 

below going through the roof (See 

Figures 22b and 22d).

•  Warning: Do not install in a 

sleeping room.

•  Caution: The structural integrity 

of the manufactured home floor, 

wall, and ceiling/roof must be 

maintained.

       WARNING

The fireplace must be installed 

with an outside air kit intake, 

which is included with the fire-

place

3

  WARNING

THE FIREPLACE MUST BE OPER-

ATED WITH THE DOORS FULLY 

OPENED OR DOORS FULLY CLOSED. 

IF THE DOORS ARE LEFT PARTLY 

OPENED, GAS AND FLAME MAY BE 

DRAWN OUT OF THE FIREPLACE 

OPENING, CREATING RISKS OF 

BOTH FIRE AND SMOKE.  IF THE 

UNIT IS OPERATED WITH THE 

DOORS FULLY OPENED, THE FIRE 

SCREEN MUST BE USED. 

    WARNING

THIS FIREPLACE HAS NOT BEEN 

TESTED WITH AN UNVENTED 

GAS   OR A FIREPLACE INSERT.  

TO REDUCE RIS K OF FIRE OR 

INJURY, DO NOT INSTALL AN 

UNVENTED GAS LOG SET OR 

FIREPLACE INSERT OR OTHER 

PRODUCTS NOT SPECIFIED FOR 

USE WITH THIS FIREPLACE.

Содержание WCT4820

Страница 1: ...hot during operation and will retain heat for a while after shutting off the appli ance Severe burns may result Carefully supervise children in the same room as appliance If small children are presen...

Страница 2: ...gths Elbows where necessary Associated components as per these installation instructions 6 diameter chimney Canada Models ASHT S2100 manufacture by Security Chimneys or DuraTech Canada DTC manufacture...

Страница 3: ...ys ensure that the air inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air WARNING Neither the manufacturer nor the seller warrants smoke free oper...

Страница 4: ...the primary air and air boost controls fully openedduring10to20minutesafterreloading depending on the heat and on the moisture content of the wood Onceyouhavereachedthedesiredtemperature the air boost...

Страница 5: ...mmended Carbon Monoxide Poisoning Early signs of carbonmonoxidepoisoningaresimilartotheflu withheadaches dizzinessand ornausea Ifyou have these signs obtain fresh air immediately Somepeoplearemoreaffe...

Страница 6: ...The use of a firewood moisture meter is rec ommended to ensure the firewood contains less than 20 moisture Seasoning Guide Softwoods 6 months to 18 months Hardwoods 12 months to 24 months Logsthatare5...

Страница 7: ...ng the hinge screws Figure 5 Figure 6 Door Installation Figure 7 Hinge Screws Gasket Adjustment Screw 1 2 3 7 6 5 4 WARNING Use only a IHP glass doors specifically designed for the WCT4820WS fireplace...

Страница 8: ...of the fireplace The combustible floor in front of the fireplace must be covered with a non combustible ma terial tile marble stone etc See Figure 9 COLD CLIMATE INSTALLATIONS Climates where temperat...

Страница 9: ...ols closed the glass will tend to get dirty unless the fuel firebox and glass are maintained at hot temperatures see RefuelingForBestPerformance Tocleanthe glass there are a number of specially design...

Страница 10: ...ion instructions Productdesigns materials dimensions specifications colors and pricesaresubjecttochangeordiscontinu ance without notice All framing dimensions calculated for 1 2 dry wall at the firepl...

Страница 11: ...t Be Used To Cover Chase Opening 8 Level 8 2 4 m Level Outside Base Insulation Thermal Barrier Solid Continuous Surface NOTE Itisrecommendedthatthechasewalls andfloorbeinsulatedinthesamemanner usingth...

Страница 12: ...e than ten 10 feet 3050 mm above the base of the fireplace C The fresh air must come from outside the house Theairintakemustnotdrawairfrom the attic basement or garage D The air intake should be insta...

Страница 13: ...Phillips screwdriver GENERAL INFORMATION If you encounter any problems need clarification of these instructions or are not qualified to properly install this kit contact you local distribu tor or dea...

Страница 14: ...Min Duct Ring Duct Adaptor Tab It is recommended that the ducted flex kit duct system be installed in the following order 1 Plan and frame fireplace and outlet locations prior to ducted flex kit insta...

Страница 15: ...grill The minimum height from thebottomoftheunittothecenteroftheoutletis68 1 7m with the minimum distance from the center of outlet to the ceiling and for the center of the outlet to a side wall of 1...

Страница 16: ...chieved by having the chimney supported by the supports The maximum chimney length that can be supported by the fireplace is nine 9 feet 2 75 m 6 The chimney must extend at least three 3 feet 915 mm a...

Страница 17: ...er of equal size to the joist should be used Figure 26 FEMALE END MALE END BUTTON LOCK ATTACH FOR LOCK Figure 27 INSULATION SHIELD CAT NO SPIS NAIL FIRESTOP CAT NO SPFS Chimney Flue Diameter 6 A 12 7...

Страница 18: ...ance to combustibles AT THIS POINT TIGHTEN CLAMPS 11 Slide IHP chimney pipe into top of tee Align male and female ends Push down on pipe sec tions until locked As sections are added it will be necessa...

Страница 19: ...all the next SP chimney section through the roof See Figure 32 NOTE If your roof is already shingled be sure to slide the upper edge under the shingles to prevent leakage 3 Install a bead of caulk aro...

Страница 20: ...verse wind conditions etc may create a need for a taller chimney should smoking occur Additional support is required above the roof if the chimney height exceeds four 4 feet Select the proper support...

Страница 21: ...d with a chimney adaptor suitable for use with IHP SnapPak venting In Canada the use of Security Chimneys ASHT adaptor is required Security part number 6IHP1 or 6IHP2 One inch wall Two inch wall Figur...

Страница 22: ...chimney at 30 3 Increase the size of the hole until a 30 liner elbow can be easily slipped through 4 Slide the liner down from the top of the masonry chimney until you reach the hole level 5 Slip thro...

Страница 23: ...90 OPTIONAL INSTALLATION ACCESSORIES Fireplace Kits Description Cat Part No Blower heat activated on off pre wired UZY5 UZY5 Blower motor speed control wall mount VRUW VRUW Central Forced Air Kit Acce...

Страница 24: ...c blower VTU Bracket secondary air tube PR SR2214 Hinge assembly fireplace and door PR SR2395UL Door handle rod and mechanism PR SR2118 Door handle and brass cap PR SR2325 Door handle brass cap POIGNE...

Страница 25: ...and Misc Chimney Components 8 length 6 Dia 6DTC 08SS 12 length 6 Dia 6DTC 12SS 18 length 6 Dia 6DTC 18SS 24 length 6 Dia 6DTC 24SS 36 length 6 Dia 6DTC 36SS 48 length 6 Dia 6DTC 48SS Adjustable Length...

Страница 26: ...NERIE TEL QUE D CRIT DANS LE MANUEL D INSTALLATION LES COMPOSANTES UTILIS ES AVEC LE FOYER DOIVENT TRE HO MOLOGU ES VOIR LA LISTE DANS LE MANUEL D INSTALLATION REMPLACER LA VITRE AVEC UN VERRE C RAMIQ...

Страница 27: ...l use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning cha...

Страница 28: ...or any questions or concerns REPLACEMENT PARTS See Page 24 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP di...

Отзывы: