4
900464-01C
SuperiorFireplaces.us.com
CAUTION: Do not remove the data plates from the
grate assembly. The data plates contain important
warranty and safety information.
UNPACKING
PRODUCT FEATURES
OPERATION
This appliance is dual listed as a vented decorative gas appliance to
ANSI Z21�60 for use indoors in wood burning fireplaces and as an
outdoor decorative gas appliance to ANSI Z21�97� When operated as
an outdoor decorative gas appliance, it must be installed outdoors in
a site built wood burning fireplace or a UL 127 listed wood burning
fireplace designed for outdoor use or in an unvented outdoor fireplace�
If optional accessory MFEB is used, the fireplace in which the appli-
ance is installed must have a working vent/flue as described within
these instructions�
ELECTRONIC IGNITION SYSTEM
This appliance has an electronic igniter to light appliance fuel supply�
LOCAL CODES
Install and use appliance with care� Follow all local codes� In the
absence of local codes, use the latest edition of The National Fuel
Gas Code, ANSI Z223.1/NFPA 54*�
The appliance when installed, must be electrically grounded in ac-
cordance with local codes, or in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70*�
*Available from:
American National Standards Institute, Inc�
25 West 43rd Street, 4th floor
New York, NY 10036
National Fire Protection Association, Inc�
1 Batterymarch Park
Quincy, MA 02169-7471
1� Remove logs and appliance base assembly from carton(s)�
2� Remove all protective packaging applied to logs and appliance for
shipment�
3� Check appliance for any shipping damage� If appliance is damaged,
promptly inform dealer where you purchased the appliance�
6� If fireplace has glass doors, never operate this appliance with
glass doors closed� If you operate appliance with doors closed,
heat buildup inside fireplace will cause glass to burst� Make sure
there are no obstructions across openings of fireplace�
7� To prevent the creation of soot, follow the instructions in Cleaning
and Maintenance, Page 17�
8� Before using furniture polish, wax, carpet cleaner or similar products,
turn appliance off� If heated, the vapors from these products may
create a white powder residue within burner box or on adjacent walls
and furniture�
9� Do not use this appliance as a wood burning appliance� Use only
the logs provided with the appliance� Do not burn solid fuels in
this appliance�
10�Do not run appliance
• where flammable liquids or vapors are used or stored
• under dusty conditions
11�Do not use this appliance to cook food or burn paper or other
objects�
12� Do not use this appliance if any part has been under water� Immedi-
ately call a qualified service technician to inspect the appliance and
to replace any part of the control system and any gas control that
has been under water�
13�Do not operate appliance if any log is broken�
14�Turn appliance off and let cool before servicing, installing or
repairing� Only a qualified service person should install, service
or repair appliance�
15�This appliances must not be connected to any external electrical
source�
16�Operating appliance above elevations of 4,500 feet may cause
pilot outage�
17�To prevent performance problems, do not use propane/LP fuel
tank of less than 100 lb� capacity (propane/LP units only)�
18�Provide adequate clearances around air openings�
19�Do not operate fireplace if any log is broken�
20� Solid fuels shall not be burned in this appliance�
PRODUCT IDENTIFICATION
LEFT
SIDE
RIGHT
SIDE
Figure 1 - Product Identification
• The flexible gas line connector used shall not exceed 36 inches
(92 centimeters) in length�
• The individual manual shut-off must be a T-handle type valve�
• Unvented appliances may NOT be installed in bedrooms or bath-
rooms�
• A working smoke detector must be installed in the area where
vent-free appliances are installed�
Seller of unvented propane or natural gas-fired supplemental room
heaters shall provide to each purchaser a copy of 527 CMR 30 upon
sale of the unit�
COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS
These appliances are approved for installation in the US state of Mas-
sachusetts if the following additional requirements are met:
• Un-vented Room Heaters shall be installed in accordance with
527 CMR 30�
• Installation and repair must be done by a plumber or gas fitter
licensed in the Commonwealth of Massachusetts�
SAFETY