42
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Installation and Operation Instructions
900299-00, 05/2016
Innovative Hearth Products
DRT40 Multi-View Series Direct-Vent Gas Fireplace
In Canada:
THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIRE-
MENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCOR-
DANCE WITH THE REQUIREMENTS OF THE CAN/CGA-B149.1 INSTALLATION CODE.
LA CONVERSION DEVRA ÊTRE EFFECTUÉE CONFORMÉMENT AUX RECOMMANDA-
TIONS DES AUTORITÉS PROVINCIALES AYANT JURIDICTION ET CONFORMÉMENT
AUX EXIGENCES DU CODE D'INSTALLATION CAN/CGA-B149.1.
Gas conversion kits are available to adapt your appliance from the use of one type of gas to the
use of another. These kits contain all the necessary components needed to complete the task
including labeling that must be affixed to ensure safe operation.
Kit part numbers are listed here and the following steps detail the conversion procedure. Refer
to the instructions provided with the conversion kit when performing any gas conversion.
GAS CONVERSION KITS
INSTALLATION INSTRUCTIONS
Step 1. TURN OFF THE GAS SUPPLY TO THE
APPLIANCE and disconnect power supply at the
circuit breaker. Ensure appliance is cold.
CAUTION: THE GAS SUPPLY SHALL BE
SHUT OFF PRIOR TO DISCONNECTING THE
ELECTRICAL POWER, BEFORE PROCEED-
ING WITH THE CONVERSION.
ATTENTION: AVANT D’EFFECTUER
LA CONVERSION, COUPEZ D’ABORD
L’ALIMENTATION EN GAZ, ENSUITE,
COUPEZ L’ALIMENTATION ÉLECTRIQUE.
a. Open the control compartment access panel,
by lifting panel approximately 1/2" to disengage
and swing the panel open from top.
b. Remove the bottom control compartment
access panel by compressing the spring-loaded
hinge pin on the left side until it disengages from
the left cabinet panel hole. Pull the panel away
from the fireplace.
c. Remove the modesty panel by pulling the
bottom right corner of the modesty panel out
slightly to disengage the snap-fit feature; lift the
modesty panel by the tab on the panel's right
end, pull the right end of the panel away from
the cabinet and then pull the panel diagonally
out of the left side cabinet panel slots. (In the
above procedure, reverse the words "left" and
"right" for DRT40CR models). Remove the
modesty panel carefully, so that none of the
wires become loose or disconnected.
WARNING
This conversion kit shall be installed by a qualified service agency in
accordance with the manufacturer’s instructions and all applicable codes
and requirements of the authority having jurisdiction. If the information in
these instruction is not followed exactly, a fire, explosion or production of
carbon monoxide may result causing property damage, personal injury
or loss of life. The qualified service agency is responsible for the proper
installation of this kit. The installation is not proper and complete until the
operation of the converted appliance is checked as specified in the manu-
facturer’s instructions supplied with the kit.The qualified service agency
performing this installation assumes responsibility for this conversion.
AVERTISSEMENT
Cette trousse de conversion doit être installée par un technicien agréé,
selon les instructions du fabricant et selon toutes les exigences et tous les
codes pertinents de l’autorité compétente. Assurez-vous de bien suivre
les instructions dans cette notice pour réduire au minimum le risque
d’incendie, d’explosion ou la production de monoxyde de carbone pouvant
causer des dommages matériels, des blessures ou la mort. Le tecnicien
agréé est responsable de l’installation de cette trousse. L’installation n’est
pas adéquate ni complète tant que le bon fonctionnement de l’appareil
converti n’a pas été vérifié selon les instructions du fabricant fournies avec
la trousse. Le fournisseur de service qualifié ayant réalisé l'installation
assume les responsabilités liées à la conversion.
Natural to Propane Conversion Kit
Models
Unit type
Catalog No.
ST and PF
Millivolt
F2314
ST and PF
Electronic
F2316
CL and CR
Millivolt
F2315
CL and CR
Electronic
F2317
Propane to Natural Gas Conversion Kit
Models
Unit type
Catalog No.
ST and PF
Millivolt
F2318
CL and CR
Millivolt
F2319