13
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Installation and Operation Instructions
900299-00, 05/2016
Innovative Hearth Products
DRT40 Multi-View Series Direct-Vent Gas Fireplace
Gas Line
Center of gas line
is 3 in. (76 mm)
up from floor.
*41-1/2
(1054)
***48-1/2
(1232)
26-3/4
(679)
11-3/8
(267)
Dimension A
Secure Vent - 47-1/8 (1197)
Secure Flex - 47-3/4 (1213)
7
(178)
5-1/8
(130)
12-1/8
(308)
10-1/2
**22-3/4
(578)
LibraST
(See-Through)
VENT FRAMING -
TOP VENT WITH
ONE 90º ELBOW
VENT FRAMING -
REAR VENT WITH
NO ELBOWS
inches (millimeters)
7
(178)
5-1/8
(130)
12-1/8
(308)
6-1/4
(159)
A
Minimum Framing
Stud Size is 2x4
*This dimension can be reduced to 41 inches (1041 mm). This results in 0 in. (0 mm)
clearance between framing and unit framing spacers. (The 41-1/2 in. dimension permits
easier fireplace installation, if unit is installed after framing is erected.)
**This dimension based on 5/8” drywall.
For 1/2” drywall use 23”.
***Provide Additional Space For
Side Vent
Seal Cap
If Installing Against A Solid Wall
LibraPF
(Peninsula)
Gas Line
Center of gas line
is 3 in. (76 mm)
up from floor.
*41-1/2
(1054)
***43-5/8
(1108)
26-3/4
(679)
11-3/8
7
(178)
5-1/8
(130)
12-1/8
(308)
VENT FRAMING -
TOP VENT WITH
ONE 90º ELBOW
VENT FRAMING -
REAR VENT WITH
NO ELBOWS
inches (millimeters)
7
(178)
(130)
(308)
6-1/4
(159)
A
Minimum Framing
Stud Size is 2x4
(267)
(289)
**22-3/4
(578)
Dimension A
Secure Vent - 47-1/8 (1197)
Secure Flex - 47-3/4 (1213)
*This dimension can be reduced to 41 inches (1041 mm). This results in 0 in. (0 mm)
clearance between framing and unit framing spacers. (The 41-1/2 in. dimension permits
easier fireplace installation, if unit is installed after framing is erected.)
**This dimension based on 5/8” drywall.
For 1/2” drywall use 23”.
***Provide Additional Space For
Side Vent
Seal Cap
If Installing Against A Solid Wall
10-1/2
12-1/8
5-1/8
Figure 14
Figure 13
Figure 15
Figure 16
FIREPLACE FRAMING SPECIFICATIONS
DRT40ST
(See Through)
DRT40CL (Corner Left)
DRT40PF
(Peninsula)
DRT40CR (Corner Right)