18
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Installation and Operation Instructions
900299-00, 05/2016
Innovative Hearth Products
DRT40 Multi-View Series Direct-Vent Gas Fireplace
NOTE: Convert inches into metric equivalent
measurement, as follows:
Millimeters (mm) = Inches x 25.4
Centimeters (cm) = Inches x 2.54
Meters (M) = Inches x .0254
T
R
A
H
C
H
T
G
N
E
L
N
O
I
T
C
E
S
T
N
E
V
l
a
n
i
m
o
N
h
t
g
n
e
L
n
o
it
c
e
S
)
s
e
h
c
n
i(
6
2
1
4
2
6
3
8
4
T
O
T
A
L
Q
T
Y
n
o
it
c
e
S
t
e
N
)
s
e
h
c
n
i(
h
t
g
n
e
L
2
/
1
-
4
2
/
1
-
0
1
2
/
1
-
2
2
2
/
1
-
4
3
2
/
1
-
6
4
t
n
e
V
f
o
t
h
g
i
e
H
s
n
o
it
c
e
S
t
n
e
V
f
o
r
e
b
m
u
N
s
e
h
c
n
i
tf
5
.
4
5
7
3
.
0
1
0
0
0
0
1
9
5
7
.
0
2
0
0
0
0
2
5
.
0
1
5
7
8
.
0
0
1
0
0
0
1
5
1
5
2
.
1
1
1
0
0
0
2
5
.
9
1
5
2
6
.
1
2
1
0
0
0
3
1
2
5
7
.
1
0
2
0
0
0
2
5
.
2
2
5
7
8
.
1
0
0
1
0
0
1
5
.
5
2
5
2
1
.
2
1
2
0
0
0
3
5
.
1
3
5
2
6
.
2
0
3
0
0
0
3
5
.
4
3
5
7
8
.
2
0
0
0
1
0
1
5
.
7
3
5
2
1
.
3
1
1
1
0
0
3
5
.
3
4
5
2
6
.
3
0
2
1
0
0
3
5
4
5
7
.
3
0
0
2
0
0
2
5
.
6
4
5
7
8
.
3
0
0
0
0
1
1
5
.
9
4
5
2
1
.
4
1
0
2
0
0
3
1
5
5
2
.
4
1
0
0
0
1
2
5
.
5
5
5
2
6
.
4
0
1
2
0
0
3
7
5
5
7
.
4
0
0
1
1
0
2
6
6
5
2
.
5
0
2
2
0
0
4
5
.
7
6
5
2
6
.
5
0
0
3
0
0
3
9
6
5
7
.
5
0
0
0
2
0
2
2
7
6
1
0
3
0
0
4
5
.
3
7
5
2
1
.
6
1
0
0
2
0
3
5
.
9
7
5
2
6
.
6
0
1
0
2
0
3
1
8
5
7
.
6
0
0
0
1
1
2
0
9
5
.
7
0
2
1
0
1
4
5
.
1
9
5
2
6
.
7
0
0
2
0
1
3
3
9
5
7
.
7
0
0
0
0
2
2
6
9
8
1
0
1
2
0
4
5
.
7
9
5
2
1
.
8
1
0
0
0
2
3
2
0
1
5
.
8
2
0
0
0
2
4
5
.
3
0
1
5
2
6
.
8
0
0
0
3
0
3
8
0
1
9
1
0
0
3
0
4
4
1
1
5
.
9
0
2
0
0
2
4
7
1
1
5
7
.
9
1
0
5
0
0
6
5
.
8
1
1
5
7
8
.
9
1
1
0
3
0
5
6
2
1
5
.
0
1
0
0
1
3
0
4
5
.
0
3
1
5
7
8
.
0
1
1
0
1
3
0
5
5
3
1
5
2
.
1
1
0
0
6
0
0
6
8
3
1
5
.
1
1
0
0
0
4
0
4
5
.
9
3
1
5
2
6
.
1
1
0
0
0
0
3
3
5
.
2
4
1
5
7
8
.
1
1
1
0
0
4
0
5
T
R
A
H
C
H
T
G
N
E
L
N
O
I
T
C
E
S
T
N
E
V
n
o
it
c
e
S
l
a
n
i
m
o
N
)
s
e
h
c
n
i(
h
t
g
n
e
L
6
2
1
4
2
6
3
8
4
T
O
T
A
L
Q
T
Y
n
o
it
c
e
S
t
e
N
)
s
e
h
c
n
i(
h
t
g
n
e
L
2
/
1
-
4
2
/
1
-
0
1
2
/
1
-
2
2
2
/
1
-
4
3
2
/
1
-
6
4
t
n
e
V
f
o
t
h
g
i
e
H
s
n
o
it
c
e
S
t
n
e
V
f
o
r
e
b
m
u
N
s
e
h
c
n
i
tf
4
4
1
2
1
1
0
0
0
3
4
0
5
1
5
.
2
1
0
1
0
0
3
4
5
.
4
5
1
5
7
8
.
2
1
1
1
0
0
3
5
5
.
0
6
1
5
7
3
.
3
1
0
2
0
0
3
5
5
.
2
7
1
5
7
3
.
4
1
0
0
0
5
0
5
7
7
1
5
7
.
4
1
1
0
0
5
0
6
3
8
1
5
2
.
5
1
0
1
0
5
0
6
6
8
1
5
.
5
1
0
0
0
0
4
4
5
.
0
9
1
5
7
8
.
5
1
1
0
0
0
4
5
5
.
6
9
1
5
7
3
.
6
1
0
1
0
0
4
5
5
.
5
0
2
5
2
1
.
7
1
0
1
1
5
0
7
7
0
2
5
2
.
7
1
0
0
0
6
0
6
5
.
1
1
2
5
2
6
.
7
1
1
0
0
6
0
7
5
.
7
1
2
5
2
1
.
8
1
0
1
0
6
0
7
5
.
9
2
2
5
2
1
.
9
1
0
0
1
6
0
7
5
.
2
3
2
5
7
3
.
9
1
0
0
0
0
5
5
7
3
2
5
7
.
9
1
1
0
0
0
5
6
5
.
1
4
2
5
2
1
.
0
2
0
0
0
7
0
7
6
4
2
5
.
0
2
1
0
0
7
0
8
2
5
2
1
2
0
1
0
7
0
8
4
6
2
2
2
0
0
1
7
0
8
6
7
2
3
2
0
0
0
8
0
8
9
7
2
5
2
.
3
2
0
0
0
0
6
6
5
.
0
8
2
5
7
3
.
3
2
1
0
0
8
0
9
5
.
3
8
2
5
2
6
.
3
2
1
0
0
0
6
7
5
.
9
8
2
5
2
1
.
4
2
0
1
0
0
6
7
5
.
1
0
3
5
2
1
.
5
2
0
0
1
0
6
7
5
.
0
1
3
5
7
8
.
5
2
0
0
0
9
0
9
5
1
3
5
.
6
2
1
0
0
9
0
0
1
5
.
5
2
3
5
2
1
.
7
2
0
0
0
0
7
7
0
3
3
5
.
7
2
1
0
0
0
7
8
6
3
3
8
2
0
1
0
0
7
8
5
4
3
5
7
.
8
2
0
0
0
0
1
0
0
1
5
.
9
4
3
5
2
1
.
9
2
1
0
0
0
1
0
1
1
2
7
3
1
3
0
0
0
0
8
8
5
.
6
7
3
5
7
3
.
1
3
1
0
0
0
8
9
5
.
9
7
3
5
2
6
.
1
3
0
0
0
1
1
0
1
1
5
.
8
1
4
5
7
8
.
4
3
0
0
0
0
9
9
3
2
4
5
2
.
5
3
1
0
0
0
9
0
1
5
6
4
5
7
.
8
3
0
0
0
0
0
1
0
1
SV4.5CGV-1
Termination
SV4.5FA OR
SV4.5FB Flashing
AND SV4.5SC
STORM COLLAR
*SV4.5VF
Firestop/Spacer
SV4.5L6/12/24/36/48
Vent Sections
40' Max
(12.2 M)
1" (26 mm)
Minimum
Clearance to
Combustibles
*When using Secure Flex,
use Firestop/Spacer
SF4.5VF
NOTE: Attic insulation shield (H3907,
see Page 41) must be installed when
blown or loose-fill insulation is used,
and is required for all attic installa-
tions.
Effective Vent Length
Model
Effective Length
SV4.5L6
4-1/2"
SV4.5L12
10-1/2"
SV4.5L24
22-1/2"
SV4.5L36
34-1/2"
SV4.5L48
46-1/2"
Table 7
Figure 25
VERTICAL TERMINATION SYSTEMS (ROOF)
See
Figure 25
and
Figures 35 through 39
on
Pages 21 and 22
and their associated
Vertical Vent Tables which illustrate the various
vertical venting configurations that are possible
for use with these appliances. Secure Vent
®
pipe
applications are shown in these Figures; Secure
Flex
®
pipe may also be used. A Vertical Vent
Table summarizes each system’s minimum and
maximum vertical and horizontal length values
that can be used to design and install the vent
components in a variety of applications.
Both these vertical vent systems terminate
through the roof. The minimum vent height
above the roof and/or adjacent walls is speci-
fied in ANSI Z223.1-(latest edition) (In Canada,
the current CAN/CGA-B149.1 installation code)
by major building codes. Always consult your
local codes for specific requirements. A general
guide to follow is the Gas Vent Rule (refer to
Figure 5
on
Page 8)
.
Vertical (Straight) Installation
(Figure 25)
Determine the number of straight vent sec-
tions required. 4-1/2" (114 mm), 10-1/2" (267
mm), 22-1/2" (572 mm), 34-1/2" (876 mm)
and 46-1/2" (1181 mm) net section lengths
are available (see
Tables on this page
and
Page 40 - Rigid Vent Sections)
. Plan the vent
lengths so that a joint does not occur at the
intersection of ceiling or roof joists. Refer to
the Vent Section Length Chart.