33
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Installation and Operation Instructions
900300-00, 01/2018
Innovative Hearth Products
DRT35ST and DRT35PF Direct-Vent Gas Fireplaces
Position The Groove At The Bottom Of
Log (A) Over The Grate And Slide It
Forward Against The Grate Here
Step 9. INSTALL VERMICULITE, GLOWING EMBERS AND LOGS
NOTE:
Turn off all electricity to the appliance before you install vermiculite,
embers and logs. DO NOT attempt to install the logs until the appliance
installation has been completed, the gas line connected and tested for
leaks and the initial burner operation has been checked out.
INSTALLATION STEPS:
READ WARNINGS ON
PAGE 34
BEFORE PROCEEDING
1.
Remove the front glass enclosure panel
(see
Glass Enclosure Panel
Removal Instructions
,
Page 35
)
.
2.
Remove the following from firebox
; log set, bag of embers and bag
of vermiculite.
Handle logs carefully to prevent breakage.
3
.
Ensure the Grate is properly installed
in the firebox with the 4 legs
of the grate fitting into the 4 dimples on the firebox floor.
4.
Install Vermiculite
- Place some vermiculite on the firebox floor around
the grate (the entire bag of vermiculite will NOT be used). See
Figure
63 on Page 36.
DO NOT PLACE ANY VERMICULITE ON THE BURNER.
5.
Placement of Glowing Embers -
Separate the Embers (rockwool) into pieces about the size of a quarter
(see
Figure 54
).
Keep the pieces fluffed up, not matted. Distribute
these pieces over the surface of the burner, as shown in
Figure 58.
Do not use more than is necessary. Ensure that the main burner ports
remain uncovered by the ember material.
NOTE:
This appliance is provided with enough Glowing Embers for
several applications, do not use all that is in a new bag at one time. For
best glowing effect, replace the ember material annually. Replacement
Glowing Embers are available (order Catalog Number 88L53).
B
A
(Valve Access Side)
(Valve Access Side)
Position Groove At The Bottom Of
Log (A) Over The Log Support Here
7.
Place Log (B) as shown in
Figure 57.
Position Log (B) Against The Back Of
The Grate Here
Position Groove at The Bottom Of Log (B) Over The
Grate Here And Slide It Against The Back Of The Grate
Figure 57
9.
Place Log (D) as shown in
Figure 59.
6.
Place Log (A) on the grate as shown in
Figure 56.
Figure 58
8.
Place Log (C) as shown in
Figure 58.
C
(Valve Access Side)
Log (C) Lays Over Logs (A) and (B)
A
B
Position The Groove in The Back of Log (C)
Against The Grate
D
(Valve Access Side)
Position And Slide Log (D) Against The
Back Of The Grate
A
Figure 59
Place Log (D) Over The
Flat Spot On Log (A) Here
Figure 55
Place
Embers
on burner as shown.
DO NOT PLACE EMBERS OVER
GAS PORTS / AREAS CIRCLED