background image

27

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Installation and Operation Instructions

900300-00, 01/2018

Innovative Hearth Products
DRT35ST and DRT35PF Direct-Vent Gas Fireplaces

GEAR

CLAMPS

Adapter

(SV4.5RF)

Apply  ONLY  MIL-PAC  BLACK  HIGH

TEMPERATURE SEALANT (Catalog No.

10K81) to the outside surface of both

collars of the adapter (be especially

careful to fill the grooves of the outer

collar to be covered by the flexible

pipe)  and  slide  flexible  pipe  over

inner  and  outer  adapter  collars.

NOTE:  OUTER PIPE IS PULLED AWAY TO

SHOW THE DETAIL OF THE INNER PIPE

FLEX VENT

1-3/4 in. (44 mm)

Flexible Pipe and

 Adapter Outer

Collar Overlap

1-3/4 in. (44 mm)

Flexible Pipe and

 Adapter Inner

Collar Overlap

SECURING SCREW

(3 PLACES EQUALLY SPACED

JUST BELOW GEAR CLAMP)

Attach Adapter to Appliance

Collar, or Secure Vent Sections

SECURING SCREW

(3 PLACES EQUALLY SPACED

JUST BELOW GEAR CLAMP)

5" (127 mm)

Radius Minimum

Flexible Vent Section

E. Attach Flex Vent to Termination -

  

Secure Flex

 components can be purchased 

separately and attached to bulk lengths of 

Secure Flex

 flexible tubing cut to size at the 

job site.   Secure the flexible vent to the 

Secure 

Flex

 terminations in the same manner (see

 

Figure 43

)

 

as it was attached to the adaptor.

NOTE: Secure Flex vent must be attached 

to Secure Flex terminations only.  DO NOT 

substitute Secure Vent terminations or the 

Secure Vent adaptor for Secure Flex compo-

nents. The collars of Secure Flex terminations 

and adaptors have a different circumference 

than that used with the Secure Vent pipe.  

Additionally, Secure Flex components have 

an extended length center tube for use in 

attaching the flexible vent.

See the appropriate sections and figures shown 

throughout the venting section for their instal-

lation requirements. 

Figure 44 

VERTICAL OR HORIZONTAL VENTING USING 

SECURE FLEX

®

 KITS AND COMPONENTS

Secure Flex

®

 venting kits and components may 

be used in any venting application where rigid 

Secure Vent

®

 (SV4.5) direct vent components 

can be used.  All restrictions, clearances and 

allowances that pertain to the rigid piping apply 

to the flexible venting.  

Secure Flex

 kits may 

not be modified; also, under no circumstances 

may separate sections of flex pipe  be joined 

together

Secure Flex

 kits may be added to 

the end of a vent run made up of rigid 

Secure 

Vent

 (SV4.5) vent sections provided that doing 

so does not violate any of the venting length, 

height, routing, horizontal to vertical ratio re-

quirements or clearance considerations detailed 

in this manual.

Secure Flex

 kits come with an included adaptor 

that can be fitted to the appliance collar or the 

inclined channel end of the last 

Secure Vent

 

(SV4.5) vent section in a rigid system in the 

exact same fashion as any other 

Secure Vent 

section.  Align the dimpled end of the adaptor 

over the previously installed section or appliance 

collar, adjusting the radial alignment until the 

four locking dimples of the adaptor are aligned 

with the inlets of the four incline channels of 

the last vent section or collar.  Push on the 

adaptor until it fully engages, then twist the 

adaptor clockwise running the dimples down 

and along the incline channels until they seat 

at the end of the channels.

Attach the flexible vent to the adaptor as fol-

lows 

(see Figure 43)

:

A. Install the Inner Flex Pipe - 

1.

  Install the small  gear clamp loosely around 

the inner flexible vent pipe, push it back out 

of the way.

2.

  Apply a bead of 

Mill-Pac Black (700°F) high 

temperature sealant - Catalog No. 10K81)

 

to the inner adaptor collar, approximately 

1/2" from the end.

3.

  Pull and extend the inner flexible vent pipe. 

4.

  Slide the inner flex pipe over the adaptor col-

lar. Ensure the flexible vent pipe completely 

engages the adaptor collar to a distance of 

1-3/4" from the end, and that it is free from 

damage or tears. 

5

. Slide the gear clamp down and tighten it 

fully to secure the flexible vent to the adaptor 

inner collar approximately 3/4" from the end 

of the flex.

6

. Install 

three screws 120 degrees apart

 

through the flexible vent pipe and into the 

adaptor collar just below the gear clamp to 

provide additional security to the connection.

B. Install the Outer Flex Pipe - 

1.

  Install the large gear clamp loosely around 

the outer flexible vent pipe, push it back out 

of the way.

 

2.

  Apply a bead of 

Mill-Pac Black (700°F) high 

temperature sealant - Catalog No. 10K81)

 

to the outer adaptor collar; to the grooves of 

the collar which extend approximately 1" from 

the end and to the flat surface, approximately 

1-3/8" from the end. 

3.

  Pull and extend the outer flexible vent pipe. 

4.

  Slide the outer flex pipe over the adaptor col-

lar. Ensure the flexible vent pipe completely 

engages the adaptor collar to a distance of 

1-3/4" from the end, and that it is free from 

damage or tears. 

5

.  Slide the gear clamp down and tighten it 

fully to secure the flexible vent to the adaptor 

outer collar approximately 3/4" from the end 

of the flex.

6.

  Install 

three screws 120 degrees apart

 

through the flexible vent pipe and into the 

adaptor collar just below the gear clamp to 

provide additional security to the connection.

C. Route Flex Vent - 

  

Ensure that the flex vent is properly routed to 

provide the required clearance.  Do Not allow 

the flexible vent to bend in a radius tighter than 

5" (127 mm).  Refer to 

Figure 44

. Support 

horizontal sections of flex with metal straps at 

2 foot (0.61 m) intervals. 

D. Install Firestop/Spacers at ceilings and walls - 

  

When Secure Flex penetrates a wall or ceiling, 

a firestop/spacer is required: use the SF4.5VF 

firestop/spacer for ceilings and the SF4.5HF 

firestop/spacer for walls. 

Figure 43

Содержание DRT35PF

Страница 1: ...iment Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L instal...

Страница 2: ...BEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas de contact accidentel avec la vitre chaude et doit tre install pour la protection Des enfants et...

Страница 3: ...cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio Mantenga la ropa mobiliario gasolina y otros l quidos inflamables alejados de la chimenea A n despu s de haber apagado...

Страница 4: ...nsula fireplaces 6 top standoffs taped to top of unit 7 front face assemblies with barriers NOTE If the barrier becomes dam aged the barrier shall be re placedwiththemanufacturer s barrier for this ap...

Страница 5: ...ui a t plong e dans l eau IMPROPER INSTALLATION OR USE OF THIS APPLIANCE CAN CAUSE SERIOUS INJURY OR DEATH FROM FIRE BURNS EXPLOSION OR CARBON MONOXIDE POISONING Onlytrimkit s suppliedbythemanufacture...

Страница 6: ...ALTH OF MASSACHUSETTS REQUIREMENTS Theseappliancesareapprovedforinstallationin the US state of Massachusetts if the following additional requirements are met Install this appliance in accordance with...

Страница 7: ...ome and must be installed in accordance with the manufacturer s instructions Cetappareilpeut treinstall c mmedumat ri eld originedansunemaisonpr fabriqu e U seulement ou mobile et doit tre install sel...

Страница 8: ...Feet Meters Flat to 6 12 1 0 0 3 6 12 to 7 12 1 25 0 38 7 12 to 8 12 1 5 0 46 8 12 to 9 12 2 0 0 61 9 12 to 10 12 2 5 0 76 10 12 to 11 12 3 25 0 99 11 12 to 12 12 4 0 1 22 12 12 to 14 12 5 0 1 52 14 1...

Страница 9: ...J Clearance to nonmechanical air supply inlet to building or the combustion air inlet to any other fireplace 6 150 mm for fireplaces 10 000 Btu h 3 kW 9 230 mm for fireplaces 10 000 Btu h 3 kW and 50...

Страница 10: ...nstructionmaterials However if installed on combustible materials such as carpeting vinyl tile etc a metal or woodbarriercoveringtheentirebottomsurface must be used Wall Finishes Surrounds Mantels NOT...

Страница 11: ...red 1 Remove the shipping pad exposing the front face assembly with barrier and hood Remove the hood by pulling firmly straight away from the unit 2 Remove the face assembly with barrier by lifting th...

Страница 12: ...NGES ON END WITH GLASS PANEL LibraCL SHOWN FOR LibraCR VIEW INTERCHANGE SIDES Remove these two screws and use them when installing the nailing flanges Nailing Flanges Note The nailing flanges combusti...

Страница 13: ...your installation Seealso SideVentSealCap note below 37 1 4 946 11 279 6 1 4 159 25 1 2 648 3 1 8 79 10 7 8 264 11 279 16 5 8 37 1 16 941 18 1 4 464 1 1 4 44 4 15 16 125 25 1 2 648 41 13 16 1062 40 1...

Страница 14: ...ow for gas line inlet location options Fireplace Framing Specifications Center of gas line is 3 1 8 79 mm up from floor Notes This dimension does not include the addition of drywall to the inside of f...

Страница 15: ...All appliances are factory equipped with a flexible gas line connector and 1 2 shutoff valve See Step 6 on Page 29 5 5 8 143 mm 3 1 8 79 mm Notes All appliances are factory equipped with a flexible ga...

Страница 16: ...ll such as a chase There is no requirement for inspection openings in the enclosing wall at any of the joints in the vent pipe Installation of Vent Restrictor A vent restrictor may be needed with this...

Страница 17: ...6 5 1 1 2 5 2 6 7 1 1 0 0 6 0 7 5 7 1 2 5 2 1 8 1 0 1 0 6 0 7 5 9 2 2 5 2 1 9 1 0 0 1 6 0 7 5 2 3 2 5 7 3 9 1 0 0 0 0 5 5 7 3 2 5 7 9 1 1 0 0 0 5 6 5 1 4 2 5 2 1 0 2 0 0 0 7 0 7 6 4 2 5 0 2 1 0 0 7 0...

Страница 18: ...191 mm The SV4 5LA is fitted with a locking inclined channel end identical to a normalventsectioncomponent andaplainend with 3 pilot holes Slip the plain end over the locking channel end of a standard...

Страница 19: ...The elbows feature a twist section to allow them to be routed about the center axis of their initial collar section to align with the required direction of the next vent run element Twist elbow secti...

Страница 20: ...ned together H V V1 V H Figure 29 Top Vent STRAIGHT Figure 31 Top Vent TWO 90 DEGREE ELBOWS 40 feet 12 2 meters Maximum uCeiling Firestop Spacer SV4 5VF uWhenusingSecureFlex use Firestop Spacer SF4 5V...

Страница 21: ...ing Secure Flex use Firestop Spacer SF4 5VF vWhen using Secure Flex use Firestop Spacer SF4 5HF uCeiling Firestop Spacer SV4 5VF uCeiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4 5HF Table D...

Страница 22: ...ise per foot runratiosthataresmallerareacceptableallthe way down to at or near level Use a carpenter s level to measure from a constant surface and adjust the support straps as necessary It is importa...

Страница 23: ...w box The SVHRK cap is for use with flex vent Theverticaldistancebetweentheinletandoutlet of the cap is 28 711 mm pipe IMPORTANT The vent termination is hot while in operation and for a period of time...

Страница 24: ...per foot run ratios that are smaller are acceptable all the way down to at or near level NOTE SV4 5VF Secure Vent SF4 5VF Secure Flex firestop spacer must be used anytime vent pipe passes through a co...

Страница 25: ...V vertical vent will be required Thistableshowsa1 V to5 H ratio Forevery1 foot of V vertical you are allowed 5 feet of H H1 horizontal run up to a maximum horizontal run of 20 feet Table H H H1 Maximu...

Страница 26: ...12 192 m Max V H H1 V1 v Wall Firestop Spacer SV4 5HF uCeiling Firestop Spacer SV4 5VF uCeiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4 5HF vWall Firestop Spacer SV4 5HF Figure 41 Side Vent...

Страница 27: ...ion in a rigid system in the exact same fashion as any other Secure Vent section Align the dimpled end of the adaptor overthepreviouslyinstalledsectionorappliance collar adjusting the radial alignment...

Страница 28: ...Install the junction box and receptacle outlet to the right of the valve in the front for optional blower kit See junction box and receptacle outlet as explained in steps 1 11 for B Elec tronic Wiring...

Страница 29: ...K 100 FBK 200 FBK 250 Kits Schematic Representation Only Relay Module C W FBK 250 only Plug blower into J Box receptacle for FBK 100 or FBK 200 application See View A for J Box wiring Optional Blower...

Страница 30: ...able in the U S however Canadian requirements vary depending on locality Installation must be in compliance with local codes A sediment trap is recommended in the gas piping within the home to prevent...

Страница 31: ...e pilot and burner willlightandoperateasindicatedintheinstruc tion manual Subsequent lighting of the appliance will not require such purging Inspect the pilot flame remove logs if necessary handling c...

Страница 32: ...Embers 80L42 FDVS Bag of Decorative Volcanic Stone Glowing Embers Bag of Glowing Embers rockwool Separate into Quarter Size separate Pieces F D Bottom View of Logs in packaging C E A B C F A D Top Vi...

Страница 33: ...LITEONTHEBURNER 5 Placement of Glowing Embers Separatethe Embers rockwool intopiecesabout thesizeofaquarter see Figure 54 Keep the pieces fluffed up not matted Distribute these pieces over the surface...

Страница 34: ...lectricity to the appliancebeforeyouinstallgrate volcanicstone vermiculite embers and logs This appliance is not designed to burn wood Any attempttodosocouldcauseirreparabledamageto the appliance and...

Страница 35: ...s Door Frame Figure 62 front face assembly and barrier removed to access glass door Installation and Operation Instructions 900300 00 01 2018 Innovative Hearth Products DRT35ST and DRT35PF Direct Vent...

Страница 36: ...lower control area Position the air shutter to the factory setting as shown in the table in Figure 64 2 Light appliance follow lighting procedure on lighting label in control compartment or see the In...

Страница 37: ...r Opening In This Direction Decrease Shutter Opening In This Direction Note Burners are omitted in this view for clarity Orifice This Area Must Remain Clear of Combustible Materials Installation and O...

Страница 38: ...nt la plaque murale de l interrupteur ou le thermostat mural pour liminer la poussi re et les traces de graisse ou d huile Collez l tiquette sur la surface de la plaque de l interrupteur mural qui con...

Страница 39: ...12 to 7 12 Adjustable Flashing 77L80 SV4 5FB 7 12 to 12 12 Adjustable Flashing 77L81 SV4 5SC6 Storm Collar 6 per box H6183 SV4 5HF5 Firestop Spacer 5 rigid H6184 SF4 5HF5 Firestop Spacer 5 flex H2246...

Страница 40: ...r gear clamps and flex adaptor 60L10 SF 18 18 feet 5 49 m com pressed flex Ref instr 750053M 98K03 SF 12 12 feet 3 66 m com pressed flex Ref instr 750052M H2248 SF4 5HF 10 Firestop Spacer Hori zontal...

Страница 41: ...ualified service agency in accordance with the manufacturer s instructions and all applicable codes andrequirementsoftheauthorityhavingjurisdiction Iftheinformationin these instruction is not followed...

Страница 42: ...to lift the top flange of the door frame away from the appliance Step 2 Carefully remove the log set Exercise care as not to break the log set Step 3 Referring to Figure 66 remove the burner Millivolt...

Страница 43: ...l provided in the conversion kit to the rating plate on the appliance Step 11 Turn on gas supply and test for gas leaks NOTE Front Face Assembly with barrier installed must be rein stalled prior to op...

Страница 44: ...ied installer service agency or the gas supplier AVERTISSEMENT Les enfants et les adultes devraient tre infor m s des dangersqueposentlestemp ra tures de surface lev es et se tenir distance afin d vit...

Страница 45: ...lianceand or its operating controls is dan gerous Improperinstallationor use of this appliance can cause serious injury or death from fire burns explosion or carbon monoxide poisoning WARNING Thisappl...

Страница 46: ...14 The appliance must be isolated from the gas supply piping system by closing its equipmentshutoffvalveduringanypressure testing of the gas supply piping system at test pressures equal to or less tha...

Страница 47: ...es chaudes Gas Controls Control Compartment Access Thegascontrolscanbefoundbehindthehinged drop down panel Open the control compartment access panel byliftingpanelapproximately1 2 todisengage and swin...

Страница 48: ...h and Page 61 French Millivolt appliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve Millivolt appliances are fitted with an O...

Страница 49: ...elpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptorquecontrola la chimenea Figura A o en el termostato de pared Figura B Seleccione el idioma que m s se habla en la casa 2 Si se usa u...

Страница 50: ...g the burn season inspect the horizontal terminationfordebrissuchasbirdnests leaves paper or branches Remove any items from the surfaces of the termina tion prior to use Also be aware of shrubs and pl...

Страница 51: ...ity to the appliance beforeyouinstallvermiculite embersandlogs DO NOT attempt to install the logs until the appliance installation has been completed the gas line connected and tested for leaks and th...

Страница 52: ...of Decorative Volcanic Stone Glowing Embers Bag of Glowing Embers rockwool Separate into Quarter Size separate Pieces NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE F D Bottom View of Logs in packaging...

Страница 53: ...hese pieces over the surface of the burner as shown in Figure 78 Do not use more than is necessary Ensure that the main burner ports remain uncovered by the ember material NOTE This appliance is provi...

Страница 54: ...hot up to one hour after gas supply is turned off Handle only when logs are cool Turn off all electricity to the appliancebeforeyouinstallgrate volcanicstone vermiculite embers and logs Thisappliance...

Страница 55: ...oes not soot the shutter opening must be adjusted between these two extremes Air Shutter Adjustment Guidelines Amount of Primary Air Flame Color Air Shutter Adjustment If air shutter is closed too far...

Страница 56: ...r ance is achieved 4 Leave the control knob off pilot on in the ON position and the burner OFF ON switch OFF and remote switches if applicable 5 When satisfied that the burner flame appear ance is nor...

Страница 57: ...llowing information 1 The model number of the appliance 2 The serial number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appl...

Страница 58: ...0 36 Blower Kit Variable Speed with Thermo Snap Switch 36 Pack ref Form 750028M 750029M Brickaded Wall Liner Kits Cat No ModelNo Description H3207 MBLK 35ST Interior Brick Liner Kit Brickaded Panel Li...

Страница 59: ...tion can be caused by long lateral runs too many elbows and or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in p...

Страница 60: ...t after several tries turn the gas control knob to OFF and call your service technician or gas supplier 10 Turn gas control knob counterclockwise to ON 11 Close control compartment 12 If applicable Tu...

Страница 61: ...technicien qualifi ou le fournisseur de gaz 10 Tournez le bouton de r glage du gaz en sens inverse des aiguilles d une montre jusqu sa position de marche ON 11 Fermer le compartiment de contr le 12 S...

Страница 62: ...control compartment OPERATING INSTRUCTIONS 1 If applicable Set the thermostat to lowest setting Turn wall on off switch unit mounted on off switch or remote control switch OFF 2 Turn OFF all electric...

Страница 63: ...p u r r e t n i l OFF 2 Coupez l alimentation lectrique de l appareil s il faut proc der l entretien COMMENT COUPER L ADMISSION DE GAZ DE L APPAREIL 3 Acc dez au compartiment de contr le 4 Tournez l i...

Страница 64: ...Pilot will not stay lit after carefully following the lighting instructions A Defective pilot generator thermocouple Check pilot flame it must impinge on thermocouple Figure 86 on Page 56 clean and o...

Страница 65: ...owered Check Transformer And Line Volt Supply NO Replace Pilot Assembly YES Check That Pilot Flame Makes Good Contact With Pilot Burner Flame Rod Check For Good Electrical Connection Through The Pilot...

Страница 66: ...C All 10 H6554 2 Glass Enclosure Assembly 35 SEE THROUGH 11 H7033 1 Glass Enclosure Assembly 22 SEE THROUGH 12 H6319 1 Vermiculite Bag of All 13 H6287 1 Grate Assembly All 14 69L21 4 Latch Glass Enclo...

Страница 67: ...PARTS PENINSULASHOWN 16 Complete Log Set Available Only 25 25 22 7 8 11 7 26 15 10 4 6 5 10 18 1 21 24 23 20 9 19 13 14 12 2 9 Installation and Operation Instructions 900300 00 01 2018 Innovative Hear...

Страница 68: ...68 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE NOTES Installation and Operation Instructions 900300 00 01 2018 Innovative Hearth Products DRT35ST and DRT35PF Direct Vent Gas Fireplaces...

Страница 69: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Страница 70: ...lso to discontinue colors styles and products Consult your local distributor for fireplace code information 1769 East Lawrence Street Russellville AL 35654 Printed in U S A 2015 Innovative Hearth Prod...

Отзывы: