Installation
900960-00C, 06/2019
Innovative Hearth Products
DRT3500-C Series Direct-Vent Gas Fireplaces
47
23.
Install the Finishing Materials
1. Complete finished interior wall.
NOTE:
To install the fireplace facing flush with the finished
wall, position framework to accommodate the thickness of the
finished wall.
NOTE:
See Cold Climate Insulation on
Page 11
and Vent
Termination Clearances on
Page 13
.
24.
Attach the Safety-in-Operation Warning Labels
1. Attach the furnished safety instruction labels at all fireplace
operation and control points (
Page 48
).
NOTE:
The installer MUST ensure these warnings are properly
attached during installation. The warning labels are a critical
means of informing consumers of safe operation practices.
Figure 37 - Combustible Wall Framing
Top Of Appliance
3”
(77 mm)
This Area Must
Remain Clear
of Combustible
Materials
1” Min.
(26 mm)
4” Clearance Minimum
Hood
Standoff Provides Space
From Combustible Materials
Stand Off Must Be Bent
To Vertical Position
Combustible Finished
Wall Materials