Installation
900960-00C, 06/2019
Innovative Hearth Products
DRT3500-C Series Direct-Vent Gas Fireplaces
40
Green
Ground
Screw
Black
Hot Side of
Receptacle
Tab Intact
Tab
Broken
Green
White
Neutral
Side of
Receptacle
120 VAC - Black
Neutral - White
Ground - Green
J-BOX / RECEPTACLE
WIRING 120V, 60HZ, 1PH
Junction Box
Field Wired
Factory Wired
(Power
Supply
Unswitched)
4. Connect the black power supply wire to the lower
outlet’s black and red pigtail lead (
Figures 29
and
30
). Connect the white power supply wire to the
outlet’s common terminal.
5. Connect the ground supply wire to the pigtail lead
attached to the outlet’s green ground screw. Restrain
the inlet power lead per NEC or local codes.
6. After the wiring is complete, replace the cover plate.
WARNING
Electronic models of these appliances are equipped with a three-prong (grounding)
plug utilized in connecting the electronic components to the junction box in the lower
compartment. This grounding plug provides protection against shock hazard and should be
plugged directly into a properly grounded three-prong receptacle. DO NOT cut or remove the
grounding prong from the plug.
13.
Connect the Gas Line
All codes require a shutoff valve mounted in the supply line.
Figure 31, Page 41
illustrates two methods for
connecting the gas supply. The flex-line method is acceptable in the U.S., however, Canadian requirements vary
depending on locality. Installation must be in compliance with local codes.
Figure 30 - Wiring Diagram—Junction Box
Red