23
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
WARNING
•
Operation of this appliance when not connected
to a properly installed and maintained venting
system can result in carbon monoxide (CO)
poisoning and possible death.
Figure 21A - DRI2530TEN Model
Figure 21B - DRI3030TEN Models
IMPORTANT NOTE: When opening the lower door on the face
while the insert is burning, pull at the far left or far right
vent openings, because the door is hot during operation.
Electronic Gas Control Valve
SIT Proflame, Hi/Lo
Electronic Gas Control Valve
SIT Proflame, Stepper
Electronic Pilot
Assembly
Electronic Pilot
Assembly
Unit-Mounted Controls
Unit-Mounted Controls
Intermittent/Standing Pilot Mode
(On/Auto Pilot Mode Switch)
This appliance can be switched from intermittent ignition to a standing pilot
simply by toggling the switch located in the lower control compartment
(refer to
Figure 21A and 20B
)
. To save energy, switch to intermittent
mode. To have a standing pilot which will help startup during cold climate
conditions by warming the flue and the glass, switch to standing pilot.
The standing pilot mode is indicated by a pilot that comes on and remains
lit when the fireplace is off.
AUTO
ON
ON
OFF
BLOWER
PILOT
FLAME HEIGHT
BURNER
AUTO
ON
PILOT
BURNER
TOTAL
COMFO
RT
CONTR
OL