Pre-Lighting Checklist

Be sure to check these items before the initial lighting of the insert:

c  

Gas pressure has been checked carefully - see 

Page 20

.

c  

All gas fittings have been checked for leaks.

c  

All clearances to combustibles have been met-see 

Page 14

.

c  

All combustible materials have been removed from the area 
in front of the insert.

c  

All vented areas of the insert face are unobstructed.

c  

House is ventilated to clear initial paint curing odors - see 

Page 26

.

c  

All packaging materials have been removed from the firebox.

c  

While appliance is cool, fingerprints or other marks have been 
cleaned from any plated surfaces with denatured alcohol and a 
soft cloth. Marks left on these surfaces may become permanent 
into the finish if not removed prior to burning the unit.

c  

Firebox liner panels and log set have been installed.

c  

The glass door is in place and is properly sealed.

Operating Instructions

FOR YOUR SAFETY READ BEFORE OPERATING

OPERATION

OPERATING INSTRUCTIONS

1.   STOP! Read the safety information above on this label.
2.   Read the operation section of the Installation and Operation manual.
3.   Turn the burner ON/OFF switch in the control compartment to "OFF."
4.   Turn "OFF" all electric power to the appliance.
5.   This appliance is equipped with an ignition device which automatically 

lights the pilot.  Do not try to light the pilot by hand.

6.   Wait five (5) minutes to clear out any gas. If you then smell gas, STOP!  

Follow “B” in the safety information above on this page. If you do not 

smell gas, go to the next step.

7.   Turn on all electric power to the appliance. 
8.   Turn the burner ON/OFF switch in the control compartment to ON.  After 

approximately 4 seconds the spark ignition system will spark for 60 

seconds to light the main burner.

9.   If the appliance will not operate, follow the instructions "To Turn Off 

Gas To Appliance" and call your service technician or gas supplier.

TO TURN OFF GAS TO APPLIANCE

1.  Turn the burner ON/OFF switch in the control compartment to "OFF."
2.  Turn off all electric power to the appliance if service is to be performed.
3.  Close the main line gas shut-off valve.

WARNING: If you do not follow these instructions exactly, 

a fire or explosion may result causing property damage, 

personal injury or loss of life. 

A. This appliance is equipped with an ignition device which automatically 

lights the pilot. Do not try to light the pilot by hand.

B. BEFORE OPERATING smell all around the appliance area for gas. Be sure 

to smell next to the floor because some gas is heavier than air and will 

settle on the floor.

WHAT TO DO IF YOU SMELL GAS:
•  Do not try to light any appliance.

•  Do not touch any electric switch; do not use any phone in your building.

• Immediately call your gas supplier from a neighbor’s phone. Follow the 

gas supplier’s instructions.

•  If you cannot reach your gas supplier, call the fire department.
C. If any portion of this appliance does not operate as the instructions 

indicate, do not try to repair it, call a qualified service technician.  Do not 

use tools.  Force or attempted repair may result in a fire or explosion.

D. Do not use this appliance if any part has been under water. Immediately 

call a qualified service technician to inspect the appliance and to replace 

any part of the control system and any gas control which has been under 

water.

INSTALLER INSTRUCTIONS - ATTACH SAFETY-IN-

OPERATION WARNING LABELS

It is required that the set of safety instruction labels that have 

been furnished with the appliance be affixed to the operation 

and control points of the appliance per the instructions on 

Page 

7

. It is the installers responsibility to ensure these warnings 

are properly affixed during installation. These warning labels 

are a critical step in informing consumers of safe operation 

of this appliance.

Содержание DRI2530TEN

Страница 1: ...tely call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by...

Страница 2: ...O CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas de contact ac...

Страница 3: ...o Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio Mantenga la ropa mobiliario gasolina y otros l quidos inflamable...

Страница 4: ...t Leveling 14 Fan Control Module Switch RDV 33 40 TCC models only 15 Installation 15 21 Venting Installation 15 USING THIS MANUAL Please read and carefully follow all of the instructions found in this...

Страница 5: ...avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une barri re de s curit cett...

Страница 6: ...porcionadas con estas instrucciones y prosiga de la siguiente manera 1 Identifique el interruptor de control en el panel de control del artefacto verifique que el interruptor opera el artefacto encend...

Страница 7: ...pareil Figure A Choisissezlalanguequiestprincipalementparl e dans la r sidence du propri taire En cas de doute collez l tiquette en anglais 2 Rep rezlat l commandeetnettoyez lasoigneuse ment pour limi...

Страница 8: ...se or anemia those under the influence of alcohol and those at high altitudes Turn off gas and electrical power to the appliance and allow it to cool before cleaning or servicing the appliance If the...

Страница 9: ...ver use solid fuels such as wood paper cardboard coal or any flammable liquids etc in this appliance Plated surfaces must be cleaned with glass cleaner and a clean soft cloth before firing the first t...

Страница 10: ...ural gas or propane Is NOT for use with solid fuels Is approved for sitting rooms and or bedrooms This appliance is suitable for installation into masonry or factory built fireplaces Fireplace Require...

Страница 11: ...a nationally recognized testing and certification laboratory to ANSI American National Standard Institute gas appliance safety standards This appliance has been tested and certified to ANSI Z21 88 CSA...

Страница 12: ...r Propane LP Bedrooms Remote Control Electrical The standard blower motor requires 120 Volts AC for operation The fireplaceisnotdependentontheblowertooperate WARNING Electrical Grounding Instructions...

Страница 13: ...A 31 1 2 800mm Front Opening Width B 19 1 2 495mm Height C 18 457mm Rear Width D 16 406mm Fireplace Depth Top View Left Side View Right Side View Front View A B C D Figure 3 Minimum Fireplace Cavity...

Страница 14: ...learances Please note that the DRI3030TEN 33 and DRI2530TEN 33 mantel clear ances are 4 less than the DRI3030TEN 40 and DRI2530TEN 40 mantel clearances as shown in Figure 4A DRI3030TEN 40 and DRI2530T...

Страница 15: ...for installation and vent termination These appliances are approved for use with the following vent kits Amerivent Flex Liner 3 X 35 3AFL 35 Adaptor w Flashing 4DCAT33 Termination Cap 4DVC Selkirk Fle...

Страница 16: ...e sealed around the vent pipes Use a non combustible seal off plate i e 22 gage sheet steel or unfaced fiberglass insulation 8 lb per square foot density minimum to seal around the vent pipes Whicheve...

Страница 17: ...l 33 000 BTU Natural Gas Input To convert input from 40 000 BTU s to 33 000 BTU s Assuming the front door is already removed 1 Remove the log rack Use a 5 32 allen wrench by removing two screws on the...

Страница 18: ...oundpanelsinfrontoftheholesonthesurroundbrackets Next insert two slotted 1 4 truss screws for each side surround panel and secure loosely 5 Fasten the top surround panel with the remaining two truss s...

Страница 19: ...Figure 15 The panel has keyhole slots where it mounts to the base Loosen the two nuts securing the panel using 3 8 wrench Carefully move out the panel far enough to access the back Do not pull the pa...

Страница 20: ...leak test solution retighten if necessary If the pressure is not sufficient make sure the gas supply line is large enough the supply regulator is properly adjusted and the total gas load for the resid...

Страница 21: ...air will result in bigger flames and more color To adjust the air shutter insert a regular screwdriver into the slide adjustment and slide it side to side see Figures 19a and 19b CAUTION The air shut...

Страница 22: ...ance will not operate follow the instructions To Turn Off Gas To Appliance and call your service technician or gas supplier TO TURN OFF GAS TO APPLIANCE 1 Turn the burner ON OFF switch in the control...

Страница 23: ...IT Proflame Stepper Electronic Pilot Assembly Electronic Pilot Assembly Unit Mounted Controls Unit Mounted Controls Intermittent Standing Pilot Mode On Auto Pilot Mode Switch Thisappliancecanbeswitche...

Страница 24: ...to indicate that it is ready to synchronize with the Remote transmitter Install 3 AAA type batteries in the Remote transmitter battery bay located on the base of the Remote With the batteries already...

Страница 25: ...ned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the high position s...

Страница 26: ...per main burner operation at both high and low flame OPERATION DRI3030TEN Model Only No Blue Flame Center Soot at Flame Tip Dark Orange Flame IMPROPERLY BURNING FLAME Soot above Flame Tip No Soot at F...

Страница 27: ...E RECEIVER BLOWER SPEED CONTROL PILOT ON AUTO SWITCH AC DC ADAPTER POWER OUTLET BOX 6 WHT 5 BLUE WHT BLK WHT BLK BLK BLK 4 GRN GRN 8 GRN 3 GRAY 14 RED 9 GRN 2 RED 1 RED 3 BLK 2 BLK 1 RED PILOT ROOM AI...

Страница 28: ...W 10 ORG 13 BLK 12 BRN 14 RED 4 PUR WHT BLK BLK WHT 4 GRN 8 GRN 2 BLK 3 BLK 1 RED 9 WHT 3 GRAY 2 RED GRN 1 2 3 4 1 Figure 28C Electronic Control Schematic Model DRI3030TEN NOTE SWITCH CONDITIONS GIVEN...

Страница 29: ...n those approved for use with this appliance o Check that the chimney and its outlet are open and free of soot block age or debris The venting system should be periodically examined by a qualified age...

Страница 30: ...not attempt to substitute the materials used on these doors or replace cracked or broken glass Handle this glass with extreme care Glass is susceptible to damage Do not scratch or handle roughly while...

Страница 31: ...Unplug the power supply cord from the electrical outlet prior to removing theblower Theblowercanbeaccessedthroughthebackwallofthefirebox Remove the insert face glass door log set and firebox liner pan...

Страница 32: ...and lifting up slightly and then out away from the unit 3 Lay the facade face down on a soft surface that will not scratch the paint 4 Using a 3 8 socket remove the six nuts holding the left 1 and rig...

Страница 33: ...ion on Pages 17 and 18 The main Burner comes on but then goes out Gas is not reaching the appliance Loose wires to the valve or ignition module Pilot flame is not engulf ing the sensor Obstructed vent...

Страница 34: ...equires H8457 Conversion Kit For Model DRI2530TEN with Manual Hi Lo Regulator 26 H8507 Cassette Assembly NG 40 000 BTU if LP also requires H8459 Conversion Kit For Model DRI3030TEN with Auto Hi Lo Reg...

Страница 35: ...DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE REPLACEMENT PARTS DRI3030TEN AND DRI2530TEN 1 27 26 2 3 4 5 15 6 7 16 37 14 36 25 33 34 21 22 23 13 32 31 30 29 28 8 17 9 10 11 20 19 33 21 34 22 23 12 24 18 38...

Страница 36: ...0 BTU input to optional 33 000 BTU input Cat No Description H5924 Orifice Main Burner 36 Natural Gas 33 000 BTU H5925 Orifice Main Burner 51 Propane 33 000 BTU Firebox Panel Kits required accessory Ca...

Страница 37: ...8 Black Trim Includes black trim x x x H8556 RDV DBV FP3341 D 33 x 41 Black Trim Includes black trim x x x H8557 RDV DBV FP3348 D 33 x 48 Black Trim Includes black trim x x x 75362 RDV DBV FP2941 B1 2...

Страница 38: ...000 FT 0 610 M IN CANADA 0 4500 FT 0 1370 M ELECTRICAL RATING 120 VAC 60 HZ LESS THAN 2 AMPS CHIMNEY USE 3 76 MM GAS VENT FLEX CHIMNEY LINER LISTED TO UL 1777 OR ULC S635 THIS APPLIANCE MUST BE PROPER...

Страница 39: ...CANADA 0 4500 FT 0 1370 M ELECTRICAL RATING 120 VAC 60 HZ LESS THAN 2 AMPS CHIMNEY USE 3 76 MM GAS VENT FLEX CHIMNEY LINER LISTED TO UL 1777 OR ULC S635 THIS APPLIANCE MUST BE PROPERLY CONNECTED TO A...

Страница 40: ...iance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any e...

Страница 41: ...or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c damage...

Страница 42: ...distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The serial num...

Отзывы: