39
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
SAFETY / LISTING LABEL - DRI3030TEN
DRI3030TEN
MANUFACTURED BY:
INNOVATIVE HEARTH PRODUCTS
1502 14TH ST NW
AUBURN, WA., USA 98001
SERIAL
NO.
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL
CONFORMS TO ANSI Z21.88-2014/CSA 2.33-2014 AND CAN/CGA-2.17-M91 (R2009).
THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF ANY. IF NOT, FOLLOW THE CURRENT ANSI Z223.1/NFPA
54-LATEST EDITION (USA) OR CAN/CGA B149.1-LATEST EDITION (CANADA). THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE
WITH THE MANUFACTURER’S INSTALLATION INSTRUCTION. FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES ONLY - MASONRY
OR FACTORY BUILT. THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE WITH AIR FILTERS.
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE AND MAY BE INSTALLED IN AN
AFTERMARKET, PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME WHERE NOT PROHIBITED BY LOCAL CODES. SEE OWNER’S
MANUAL FOR DETAILS. THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES UNLESS A CERTIFIED KIT IS USED.
DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.
IF ELECTRICALLY CONNECTED, CONNECTIONS AND GROUNDING MUST BE IN ACCORDANCE WITH LOCAL CODES, IF ANY. IF NOT,
FOLLOW THE CURRENT NATIONAL ELECTRICAL CODE ANSI/NFPA 70-LATEST EDITION (USA) OR CSA C22.1-LATEST EDITION (CANADA).
FACTORY EQUIPPED FOR NATURAL GAS. IF CONTROL PANEL CONTRADICTS THIS LABEL, UNIT FUEL TYPE HAS BEEN CONVERTED.
WARNING: IF UNIT IS CONVERTED TO A DRI3030TEN-40 FROM A DRI3030TEN-33 ENSURE THAT THE
CLEARANCES TO COMBUSTIBLES ARE CORRECT FOR DRI3030TEN-40.
RATINGS
DRI3030TEN-40
DRI3030TEN-33
For use only with barrier
Part No. J7510. Follow
installation instructions.
NATURAL GAS
LP GAS
NATURAL GAS
LP GAS
MAX/MIN INPUT BTUH 0-2,000 FT (0-610 M)*
40,000/28,000
37,500/26,000
33,000/24,000
33,000/24,000
MANIFOLD PRESSURE (IN. WC)
3.5
10.0
3.5
10.0
MIN. INLET PRESSURE (IN. WC)
5.0
10.5
5.0
10.5
ORIFICE (DMS) 0-2,000 FT (0-610 M)*
1/8”
#49
#36
#51
*UNIT FACTORY EQUIPPED FOR 0-2000 FT/0-610 M, IN CANADA 0-4500 FT/0-1370 M. ELECTRICAL RATING: 120 VAC, 60 HZ, LESS THAN 2 AMPS
CHIMNEY - USE 3" (76 MM) GAS VENT FLEX CHIMNEY LINER LISTED TO UL 1777 OR ULC S635.
THIS APPLIANCE MUST BE PROPERLY CONNECTED TO A VENTING SYSTEM IN ACCORDANCE WITH THE MANUFACTURER’S
INSTALLATION INSTRUCTIONS.
FOR ALTITUDES ABOVE 2,000 FT/610M (IN CANADA 4500 FT/1370M) DE-RATE THE APPLIANCE BY FOUR (4)% FOR EVERY 1,000 FT (305 M).
CAUTION:
HOT WHILE IN OPERATION. DO NOT TOUCH. SEVERE BURNS MAY RESULT. KEEP
CHILDREN, CLOTHING, FURNITURE, GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE VAPORS AWAY.
KEEP BURNER AND CONTROL COMPARTMENT CLEAN. SEE INSTALLATION AND OPERATING INSTRUCTIONS
ACCOMPANYING APPLIANCE. FOR USE WITH GLASS DOORS CERTIFIED WITH THIS APPLIANCE ONLY. DO NOT
OPERATE THE APPLIANCE WITH GLASS REMOVED, CRACKED OR BROKEN. REPLACEMENT OF THE PANEL(S)
SHOULD BE DONE BY A LICENSED OR QUALIFIED PERSON.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE
INJURY OR PROPERTY DAMAGE. REFER TO THE OWNER’S INFORMATION MANUAL PROVIDED WITH THIS
APPLIANCE. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER, SERVICE
AGENCY OR GAS SUPPLIER.
DO NOT REMOVE OR COVER THIS LABEL
Part No. 900374-00 Rev. 0, 12/2014
IGN _____
DATE OF MANUFACTURE / DATE DE FABRICATION
2014
2016
2017
2015
JAN
FEB MAR
APR MAY
JUN
JUL
AUG SEP
OCT
NOV DEC
MODEL
MINIMUM CLEARANCES
Note: Hearth protection to be min.
3/8” (10mm) thick non-combustible
or equivalent, with a k factor of .84.
A
D
B
E
C
CL
MANTEL
TRIM
MINIMUM FIREPLACE SIZES REQUIRED
....................
DRI3030TEN-40
DRI3030TEN-33
Front Opening ................................................................... 31.50” (800mm)
31.50” (800mm)
Height ................................................................................. 19.50” (495mm)
19.50” (495mm)
Rear Width ........................................................................ 18.00” (457mm)
18.00” (457mm)
Depth ................................................................................. 16.00” (406mm)
16.00” (406mm)
MINIMUM CLEARANCES TO COMBUSTIBLES
A = Top Facing to Bottom of Appliance ..................... 35.5" (902mm)
31.5" (800mm)
B = Side Facing or Side Wall to Center of Glass ...... 25.5" (648mm)
25.5" (648mm)
* C = 10.5” (267mm) Mantel to Bottom of Appliance . 43" (1092mm)
39" (991mm)
HEARTH PROTECTION
D = Vertical Distance from base of appliance 0" 2” 4” 0" 2” 4”
to Hearth Extension .......................................... (0mm) (51mm) (102mm) (0mm) (51mm) (102mm)
E = Minimum Horizontal Distance
14" 10” 0” 13" 10” 0”
from Front of Appliance .................................. (356mm) (254mm) (0mm) (330mm) (254mm) (0mm)
MANTEL
FACING
*See owner’s manual for additional mantel clearances and options.
Report No. 14-192