background image

5

Important Safety Informa-

tion

1. WARNING: Do not operate appliance 

with the glass front removed, cracked 
or broken. 

2. Do not use this appliance if any part 

has been under water. Immediately 
call a qualified service technician to 
inspect the appliance and to replace 
any part of the control system and 
any gas control which has been under 
water.

3. Due to high temperatures, the appli-

ance should be located out of traffic 
and away from furniture and draperies.

4. Children and adults should be alerted 

to the hazards of high surface tem-
perature and should stay away to avoid 
burns or clothing ignition. 

5. Clothing or other flammable material 

should not be placed on or near the 
appliance.

6. Young children should be carefully 

supervised when they are in the same 
room as the appliance. Toddlers, 
young children, and others may be sus-
ceptible to accidental contact burns. 
A physical barrier is recommended 
if there are at-risk individuals in the 
house. To restrict access to a fireplace 
or stove, install an adjustable safety 
gate to keep toddlers, young children, 
and other at-risk individuals out of the 
room and away from hot surfaces.

7. Any safety screen, guard or barrier 

removed for servicing an appliance 
must be replaced prior to operating 
the appliance.

8. Installation and repair should be done 

by a qualified service person. The 
appliance should be inspected before 
use and at least annually by a profes-
sional service person. More frequent 
cleaning may be required due to 
excessive lint from carpeting, bedding 
material, et cetera. It is imperative 
that control compartments, burners, 
and circulating air passageways of the 
appliance be kept clean. See mainte-
nance instructions on 

Pages 29-32

.

L’information de sûreté 

importante

1.  AVERTISSEMENT. Ne pas utiliser l’appareil 

si le panneau frontal en verre n’est pas en 

place, est craqué ou brisé. 

2.  Ne pas se servir de cet appareil s’il a été 

plongé dans l’eau, même partiellement. 

Faire inspecter l'appareil par un technicien 

qualifié et remplacer toute partie du systéme 

de contrôle et toute commande qui ont été 

plongées dans l'eau.

3.  En raison des températures élevées, 

l’appareil devrait être installé dans un 

endroit où il y a peu de circulation et loin 

du mobilier et des tentures.

4.  Les enfants et les adultes devraient être 

informés des dangers que posent les tem-

pératures de surface élevées et se tenir à 

distance afin d’éviter des brûlures ou que 

leurs vêtements ne s’enflamment.

5.  On ne devrait pas placer de vêtements 

ni d’autres matières inflammables sur 

l’appareil ni à proximité.

6.  Les jeunes enfants devraient être surveillés 

étroitement lorsqu’ils se trouvent dans la 

même pièce que l’appareil. Les tout petits, 

les jeunes enfants ou les adultes peuvent 

subir des brûlures s’ils viennent en contact 

avec la surface chaude. Il est recommandé 

d’installer une barrière physique si des 

personnes à risques habitent la maison. 

Pour empêcher l’accès à un foyer ou à un 

poêle, installez une barrière de sécurité 

; cette mesure empêchera les tout petits, 

les jeunes enfants et toute autre personne 

à risque d’avoir accès à la pièce et aux 

surfaces chaudes.

7.  Tout écran ou protecteur retiré pour per-

mettre l’entretien de l’appareil doit être 

remis en place avant de mettre l’appareil 

en marche.

8.  L’installation et la réparation devrait être 

confiées à un technicien qualifié. L’appareil 

devrait faire l’objet d’une inspection par un 

technicien professionnel avant d’être utilisé 

et au moins une fois l’an par la suite. Des 

nettoyages plus fréquents peuvent être 

nécessaires si les tapis, la literie, et cetera 

produisent une quantité importante de pous-

sière. Il est essentiel que les compartiments 

abritant les commandes, les brûleurs et les 

conduits de circulation d’air de l’appareil 

soient tenus propres. Voyez les instructions 

d’entretien à la 

Pages 29-32

.

Información importante de 

seguridad

1.  ADVERTENCIA: No opere el artefacto con el 

frente de vidrio quitado, agrietado o roto.  

2.  No use este artefacto si alguna de sus partes 

ha estado bajo agua. Llame de inmediato 
a un técnico de servicio calificado para 
que inspeccione el artefacto y reemplace 
cualquier parte del sistema de control y 
cualquier control de gas que haya estado 
bajo agua.

3.  Debido a las altas temperaturas, el artefacto 

debe situarse fuera de las áreas de tráfico y 
lejos del mobiliario y cortinas.

4.  Se debe alertar a los niños y adultos sobre 

los peligros de las altas temperaturas en la 
superficie y que se mantengan alejados para 
evitar quemaduras o ignición de la ropa. 

5.  No debe colocarse ropa u otros materiales 

inflamables sobre y cerca del artefacto.

6.  Se debe supervisar de cerca a los niños 

cuando estén en el mismo cuarto que el 
artefacto. Los niños pequeños, los jóvenes 
y otras personas pueden ser susceptibles 
a quemaduras por contacto accidental. Se 
recomienda instalar una barrera física si hay 
personas en riesgo en la casa. Para restringir 
el acceso a una chimenea o estufa, instale 
una puerta de seguridad ajustable para 
mantener a los niños pequeños, jóvenes y 
otras personas en riesgo fuera del cuarto y 
lejos de las superficies calientes.

7.  Cualquier malla o resguardo de seguridad 

quitado para dar servicio a un artefacto, debe 
reinstalarse antes de operar el artefacto.

8.  Una persona de servicio competente debe 

realizar la instalación y reparación. Una 
persona de servicio profesional debe 
inspeccionar el artefacto antes de usar al 
menos una vez por año. Se puede requerir 
limpieza más frecuente debido a la pelusa 
excesiva del alfombrado, del material de 
cobijas, etc. Es imprescindible mantener 
limpios los compartimientos de control, los 
quemadores y los pasajes de circulación del 
aire del artefacto. Ver las instrucciones de 
mantenimiento en la 

páginas 29-32

.

IMPORTANT SAFETY INFORMATION

Содержание DRI2530TEN

Страница 1: ...tely call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by...

Страница 2: ...O CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas de contact ac...

Страница 3: ...o Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio Mantenga la ropa mobiliario gasolina y otros l quidos inflamable...

Страница 4: ...t Leveling 14 Fan Control Module Switch RDV 33 40 TCC models only 15 Installation 15 21 Venting Installation 15 USING THIS MANUAL Please read and carefully follow all of the instructions found in this...

Страница 5: ...avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une barri re de s curit cett...

Страница 6: ...porcionadas con estas instrucciones y prosiga de la siguiente manera 1 Identifique el interruptor de control en el panel de control del artefacto verifique que el interruptor opera el artefacto encend...

Страница 7: ...pareil Figure A Choisissezlalanguequiestprincipalementparl e dans la r sidence du propri taire En cas de doute collez l tiquette en anglais 2 Rep rezlat l commandeetnettoyez lasoigneuse ment pour limi...

Страница 8: ...se or anemia those under the influence of alcohol and those at high altitudes Turn off gas and electrical power to the appliance and allow it to cool before cleaning or servicing the appliance If the...

Страница 9: ...ver use solid fuels such as wood paper cardboard coal or any flammable liquids etc in this appliance Plated surfaces must be cleaned with glass cleaner and a clean soft cloth before firing the first t...

Страница 10: ...ural gas or propane Is NOT for use with solid fuels Is approved for sitting rooms and or bedrooms This appliance is suitable for installation into masonry or factory built fireplaces Fireplace Require...

Страница 11: ...a nationally recognized testing and certification laboratory to ANSI American National Standard Institute gas appliance safety standards This appliance has been tested and certified to ANSI Z21 88 CSA...

Страница 12: ...r Propane LP Bedrooms Remote Control Electrical The standard blower motor requires 120 Volts AC for operation The fireplaceisnotdependentontheblowertooperate WARNING Electrical Grounding Instructions...

Страница 13: ...A 31 1 2 800mm Front Opening Width B 19 1 2 495mm Height C 18 457mm Rear Width D 16 406mm Fireplace Depth Top View Left Side View Right Side View Front View A B C D Figure 3 Minimum Fireplace Cavity...

Страница 14: ...learances Please note that the DRI3030TEN 33 and DRI2530TEN 33 mantel clear ances are 4 less than the DRI3030TEN 40 and DRI2530TEN 40 mantel clearances as shown in Figure 4A DRI3030TEN 40 and DRI2530T...

Страница 15: ...for installation and vent termination These appliances are approved for use with the following vent kits Amerivent Flex Liner 3 X 35 3AFL 35 Adaptor w Flashing 4DCAT33 Termination Cap 4DVC Selkirk Fle...

Страница 16: ...e sealed around the vent pipes Use a non combustible seal off plate i e 22 gage sheet steel or unfaced fiberglass insulation 8 lb per square foot density minimum to seal around the vent pipes Whicheve...

Страница 17: ...l 33 000 BTU Natural Gas Input To convert input from 40 000 BTU s to 33 000 BTU s Assuming the front door is already removed 1 Remove the log rack Use a 5 32 allen wrench by removing two screws on the...

Страница 18: ...oundpanelsinfrontoftheholesonthesurroundbrackets Next insert two slotted 1 4 truss screws for each side surround panel and secure loosely 5 Fasten the top surround panel with the remaining two truss s...

Страница 19: ...Figure 15 The panel has keyhole slots where it mounts to the base Loosen the two nuts securing the panel using 3 8 wrench Carefully move out the panel far enough to access the back Do not pull the pa...

Страница 20: ...leak test solution retighten if necessary If the pressure is not sufficient make sure the gas supply line is large enough the supply regulator is properly adjusted and the total gas load for the resid...

Страница 21: ...air will result in bigger flames and more color To adjust the air shutter insert a regular screwdriver into the slide adjustment and slide it side to side see Figures 19a and 19b CAUTION The air shut...

Страница 22: ...ance will not operate follow the instructions To Turn Off Gas To Appliance and call your service technician or gas supplier TO TURN OFF GAS TO APPLIANCE 1 Turn the burner ON OFF switch in the control...

Страница 23: ...IT Proflame Stepper Electronic Pilot Assembly Electronic Pilot Assembly Unit Mounted Controls Unit Mounted Controls Intermittent Standing Pilot Mode On Auto Pilot Mode Switch Thisappliancecanbeswitche...

Страница 24: ...to indicate that it is ready to synchronize with the Remote transmitter Install 3 AAA type batteries in the Remote transmitter battery bay located on the base of the Remote With the batteries already...

Страница 25: ...ned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the high position s...

Страница 26: ...per main burner operation at both high and low flame OPERATION DRI3030TEN Model Only No Blue Flame Center Soot at Flame Tip Dark Orange Flame IMPROPERLY BURNING FLAME Soot above Flame Tip No Soot at F...

Страница 27: ...E RECEIVER BLOWER SPEED CONTROL PILOT ON AUTO SWITCH AC DC ADAPTER POWER OUTLET BOX 6 WHT 5 BLUE WHT BLK WHT BLK BLK BLK 4 GRN GRN 8 GRN 3 GRAY 14 RED 9 GRN 2 RED 1 RED 3 BLK 2 BLK 1 RED PILOT ROOM AI...

Страница 28: ...W 10 ORG 13 BLK 12 BRN 14 RED 4 PUR WHT BLK BLK WHT 4 GRN 8 GRN 2 BLK 3 BLK 1 RED 9 WHT 3 GRAY 2 RED GRN 1 2 3 4 1 Figure 28C Electronic Control Schematic Model DRI3030TEN NOTE SWITCH CONDITIONS GIVEN...

Страница 29: ...n those approved for use with this appliance o Check that the chimney and its outlet are open and free of soot block age or debris The venting system should be periodically examined by a qualified age...

Страница 30: ...not attempt to substitute the materials used on these doors or replace cracked or broken glass Handle this glass with extreme care Glass is susceptible to damage Do not scratch or handle roughly while...

Страница 31: ...Unplug the power supply cord from the electrical outlet prior to removing theblower Theblowercanbeaccessedthroughthebackwallofthefirebox Remove the insert face glass door log set and firebox liner pan...

Страница 32: ...and lifting up slightly and then out away from the unit 3 Lay the facade face down on a soft surface that will not scratch the paint 4 Using a 3 8 socket remove the six nuts holding the left 1 and rig...

Страница 33: ...ion on Pages 17 and 18 The main Burner comes on but then goes out Gas is not reaching the appliance Loose wires to the valve or ignition module Pilot flame is not engulf ing the sensor Obstructed vent...

Страница 34: ...equires H8457 Conversion Kit For Model DRI2530TEN with Manual Hi Lo Regulator 26 H8507 Cassette Assembly NG 40 000 BTU if LP also requires H8459 Conversion Kit For Model DRI3030TEN with Auto Hi Lo Reg...

Страница 35: ...DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE REPLACEMENT PARTS DRI3030TEN AND DRI2530TEN 1 27 26 2 3 4 5 15 6 7 16 37 14 36 25 33 34 21 22 23 13 32 31 30 29 28 8 17 9 10 11 20 19 33 21 34 22 23 12 24 18 38...

Страница 36: ...0 BTU input to optional 33 000 BTU input Cat No Description H5924 Orifice Main Burner 36 Natural Gas 33 000 BTU H5925 Orifice Main Burner 51 Propane 33 000 BTU Firebox Panel Kits required accessory Ca...

Страница 37: ...8 Black Trim Includes black trim x x x H8556 RDV DBV FP3341 D 33 x 41 Black Trim Includes black trim x x x H8557 RDV DBV FP3348 D 33 x 48 Black Trim Includes black trim x x x 75362 RDV DBV FP2941 B1 2...

Страница 38: ...000 FT 0 610 M IN CANADA 0 4500 FT 0 1370 M ELECTRICAL RATING 120 VAC 60 HZ LESS THAN 2 AMPS CHIMNEY USE 3 76 MM GAS VENT FLEX CHIMNEY LINER LISTED TO UL 1777 OR ULC S635 THIS APPLIANCE MUST BE PROPER...

Страница 39: ...CANADA 0 4500 FT 0 1370 M ELECTRICAL RATING 120 VAC 60 HZ LESS THAN 2 AMPS CHIMNEY USE 3 76 MM GAS VENT FLEX CHIMNEY LINER LISTED TO UL 1777 OR ULC S635 THIS APPLIANCE MUST BE PROPERLY CONNECTED TO A...

Страница 40: ...iance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any e...

Страница 41: ...or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c damage...