Operation
900285-00 12/2016
Innovative Hearth Products
DRT3000 and DRC3000 Series Direct-Vent Gas Fireplaces
69
6-3/4"
9-5/8"
1. Slide the switch on the receiver, wall switch or ON/OFF switch to "OFF.
2. (if applicable) Press ON/OFF button on remote control transmitter to
"OFF."
P/N 900337-00, Rev. 0
DRAFT
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal
injury or loss of life.
A. This appliance is equipped with an ignition device which automatically lights
the pilot. Do not try to light the pilot by hand.
B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to
smell next to the floor because some gas is heavier than air and will settle
on the floor.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
OPERATING INSTRUCTIONS
TO TURN OFF GAS TO APPLIANCE
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
C. If any portion of this appliance does not operate as the instructions indicate,
do not try to repair it, call a qualified service technician. Do not use tools.
Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately call
a qualified service technician to inspect the appliance and to replace any
part of the control system and any gas control which has been under water.
Electronic Gas Control
Valve - SIT
Electronic Pilot Assembly
3. Turn off all electric power to the appliance if service is to be performed.
Note: The control may have a battery backup (remove batteries, if
installed).
4. Close the main line gas shut-off valve.
1. STOP! Read the safety information above on this label.
2. Read the Care and Operation manual including the section on "Remote Control
System," (if applicable).
3. Slide the switch on the receiver, wall switch or ON/OFF switch to "OFF."
4. Turn "OFF" all electric power to the appliance. Note: The control may have a
battery backup (remove batteries, if installed).
5. This appliance is equipped with an ignition device which automatically lights the
pilot. Do not try to light the pilot by hand.
6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the
floor. If you smell gas, STOP! Follow “B” in the safety information above on this
label. If you don’t smell gas, go to the next step.
7. Turn on all electric power to the appliance. Note: The control may have a battery
backup (install batteries, if applicable).
8. Slide the switch on the receiver to REMOTE or ON/OFF switch /wall switch to ON.
9. (if applicable) Press ON/OFF button on remote control transmitter to "ON."
10. (if applicable) Set thermostat on remote control to desired setting.
11. If the appliance will not operate, follow the instructions "To Turn Off Gas To
Appliance" and call your service technician or gas supplier.
DANGER
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this
appliance and shall be installed for the protection of children and other at-risk individuals.
LIGHTING INSTRUCTIONS, ELECTRONIC SIT - ENGLISH