EXPRESS START-UP PROCEDURE
STEPS NECESSARY TO BECOME OPERATIONAL
This section outlines the minimum steps necessary for the unit to become operational.
FAILURE TO PERFORM THESE STEPS MAY
RESULT IN DAMAGE TO THE DRIVE.
I. POWER SUPPLIES
Be absolutely certain that the power supplied to the Translator/Oscillator meets the following specifications:
Supply
Nominal
Voltage Range
Current
Connector J2
Type
Voltage
(Worst Case)
(Amperes)
Pin Number
Logic
+5 Vdc
+4.75 to +5.25 Vdc
(without SSP-500)
0.6*
2
+5.00 to +5.25
(with SSP-500)
0.9*
2
Digital
+15 Vdc
+12 to +16 Vdc
0.030
1
Logic
Common
—
—
—
3
Motor (Vm)
+28 Vdc
+26 to +32 Vdc
2.5 (230 drive)
4
4.0 (430 drive)
4
Motor Supply
Common
—
—
—
5
* Current Level is Logic board (Translator/Oscillator, Indexer) dependent.
The Power Supply peak ripple voltages must not go higher than 32 volts or lower than 26 volts.
POWER CONNECTOR
(mates with J2 on printed circuit board)
Superior Electric part number B209270-003
AMP part number 640599-5
MOTOR CONNECTOR
(mates with J4 on printed circuit board)
Superior Electric part number B215744-007
Electrovert part number 25.600.0753
NOTE: These parts are supplied in the accessory kit provided with your unit.