Updated: 15 November, 2011 Page 20
REF: REI-85-0045
MACHINE STOPS
SUDDENLY WHILE
OPERATING
1. Container falls down inaccurately
into lower mould.
2. Pressure is low.
3. No electricity.
4. Security door of Sealing area
unlocked.
5. Cylinder of sealing no any
response.
1. Check and wipe the sensor surface which
located at cup drop area, also adjust sensor
ray.
2. Check air compressor and pressure switch.
3. Check power plug.
4. Check micro switch and shot the security
door in property.
5. Check cylinder sensor if it is out of right
position.
FILM PATTERN
OUT OF RIGHT
POSITION WHILE
SEALING.
1. Film sensor dirty.
2. Film sensor no response.
3. Film sensor broken.
1. Wipe the film sensor surface
。
2. Adjust the ray of film sensor
。
3. Replace film sensor.
OTHERS
1. Sealing plate does not always not
enough hot when heating time over 7
minutes.
2.Always show high temperature as
soon as turning on the power of
temperature controller.
3.Unable to reach the presetting
temperature.
1. Check temperature controller, thermocouple,
and heater if they have
been turned on, broken, or burnt.
2. Thermocouple may damage, replace new one.
3. Some of heaters may be burnt.