Updated: 15 November, 2011 Page 17
REF: REI-85-0045
10. MAINTENACE
ELECTRICAL HAZARD
Always REMOVE the machine from the power outlet before performing any maintenance or cleaning
works.
BURN HAZARD
• Cleaning and maintenance should be performed by your trained personnel only
• Allow unit to cool at least 90 minutes before normal cleaning
• If hot machine must be opened, keep hands away from upper moulds and the printer
10.1
DAILY MAINTENANCE
Wipe with wet cloth the upper and lower moulds with dirt. Always remove residual films
(plastic roll films).
Clean the groove of the lower sealing mould
Clean the sensor if necessary
10.2
WEEKLY MAINTENANCE
Clean the panel box. Ensure it is free of dust, insects and etc.. If necessary, insect repellent can
be placed in the panel box.
10.3 MONTHLY MAINTENANCE
Regularly check the air pressure controller (once every month). Check lubricant oil every
month. If less than 50%, refill the lubricant oil (Specification: Number 68)
Check if all sealing springs are in good condition
Lubricate moving parts.
11. ERROR CODES AND TROUBLE SHOOTING
This error is related to the magnetic sensor
situated on the sealing cylinder.
The sensor could be faulty or has been moved
out of position. Move the magnetic sensor into
position or replace.
The error can also be caused by unstable air
pressure. Please check compressed air supply.