34
6.4. Maintenance
The Li-Ion battery is maintenance free. Charge the battery to approximately > 80% of its
capacity at least once every year to preserve the battery’s capacity.
7. Storage
Follow the storage instructions in this manual to optimize the lifespan of the battery during
storage. If these instructions are not followed and the Li-Ion battery has no charge remaining
when it is checked, consider it to be damaged. Do not attempt to recharge or use it. Replace
it with a new battery.
1. Disconnect the Li-Ion battery from all loads and, if present, the charging device.
2. To put the battery back in storage mode, 12V should be applied to pins 3/4 of connector J2.
Where PIN3 is +12V and PIN4 is GND, as shown in the pictures.
3. Place the terminal covers over the battery’s terminals during storage.
4. Store the battery in a cool and well ventilated space.
5. Avoid exposure of the battery to sunlight and/or UV radiation.
6. Charge the battery to > 80% of its capacity before storage.
7. Charge the battery to > 80% of its capacity every 100 days.
8. Transportation
8.1. General
Always check all applicable local, national, and international regulations before transporting
a Lithium Iron Phosphate battery.
Transporting an end-of-life, damaged, or recalled battery may, in certain cases, be
Содержание Epsilon SB12V1200Wh-M
Страница 1: ...Manual LITHIUM BATTERY SB12V1200Wh M 12 8 V 90 Ah 1200Wh Lithium Iron Phosphate Epsilon ...
Страница 23: ...Be in charge Super B 23 2 3 5 2x 2x Figure 3 1 2 3 13 Nm 4 5 6 2x 2x 2x Figure 4 Figure 5 ...
Страница 43: ...Be in charge Super B 43 Appendix III Performance Graphs Depth of Discharge v s Cycle life Derating performance ...
Страница 45: ...Be in charge Super B 45 ...
Страница 48: ...48 ...
Страница 49: ...Be in charge Super B 49 ...