Figure 9.
4.5. Connecting to the CAN interface (RJ45)
4.5.1. Connecting the data cables
The wired communication interface must be used in a bus network topology (Table 13). Do
not use a ring- or a star topology. The wired communication interface specifications restrict
the Bus length/Bus speed.
Bus length (L)
Max. stub length (S)
Accumulated stub length
250 m
11 m
55m
Table 14. wired network interface cable lengths
CAN Cables
Use standard UTP cable to connect the battery to your application.
Termination Resistors
A high-speed bus requires termination at the two ends of the bus.
Use termination resistors at the end nodes to impede reflections on the line. The value of this
resistor should be +/- 120 ohms.