26
OK: Equally divided battery current.
All batteries contribute equally to the current into the load.
NOT OK: Current not equally divided.
Batteries closest to load will have the highest contribution to the current into the load.
Whereas batteries further away from load will have lesser current contribution.
Wear and tear will be higher on the Li-ion battery close to the load. Never connect the setup
like this!
4.10. Disconnecting the Li-ion battery
1. Turn off any device or charger the Li-ion battery is connected to.
2. Disconnect the negative wire and accessories connection from the - terminal
of the Li-ion battery.
3. Disconnect the positive wire and accessories connection from the + terminal
of the Li-ion battery.
4. Disconnect all other connections like the FASTON and communication interface connection
which are located under the protective lid.
5. Battery use
5.1. General information
!
Warning!
Follow the safety guidelines and measures of chapter 1.
!
Caution!
Charge the Li-ion battery before use.
!
Caution!
Do not operate the Li-ion battery beyond its maximum specifications.
!
Caution!
Charging at deep discharge conditions can lead to venting, excessive heat or
thermal runaway of the cells.
!
Caution!
This Li-ion battery stores fault conditions and usage storage internally, like
excessive charge current or deep discharge situations. Super B uses this information in the
warranty process.
!
Warning!
Do not overcharge the Li-ion battery.
5.2. Charging
!
Warning!
Never charge the Li-ion battery with a charging current higher than mentioned in
table 4.
!
Caution!
Stop charging in case the Li-ion battery switches into error mode.
!
Caution!
Disconnect the charger from the Li-ion battery if it is not used for a long time.
!
Caution!
To charge the Li-ion battery, use a charger which follow Super B’s charging profile
(see charging manual which can be found on the Super B website).
1. Connect the charger to the Li-ion battery as described in paragraph 4.8.