14
Faston #
Description
Function
1
Accessory power output
Connection for power to accessories
(fused internally, resettable)
2
LIN bus connection
LIN bus communication channel (CI-
bus support)
3
IO1 connection
Input or output 1 (configurable)
4
IO2 connection
Input or output 2 (configurable)
5
SOC output (analogue)
Analogue SOC output (0-10V) (load
must be higher than 100kOhms)
6
GND connection
GND connection (fused internally,
resettable)
7
IO3 connection
Input or output 3 (configurable)
8
Heater power supply input
External power supply for heater (12-
14V) (120W / 10A max)
Table 11. FASTON connections
3.6.3. FASTON Connection electrical specifications
Description
Value
Units
I/O connection
1-3
Input voltage range
0 .. 15
V
Input impedance
>100
KOhm
Input high level
>8.4
V
Input low level
<6.8
V
Output current sink
(open drain output type)
0.5
A
SoC output
Output voltage range
0.01 .. 10
V
Output impedance
<1
Ohm
Heater input
Input voltage range
12 .. 15
V
Power rating 150Ah
120
W
Power rating 100Ah
80
W
Table 12. FASTON connection electrical specifications
3.6.4. Bluetooth
Service description
Type of signal
Range
Bluetooth Low Energy
(5.1 standard)
Communication
10 - 25 meter (typical)
Table 13. Bluetooth