Note: This is when the muting lamp diagnosis function is valid. If the muting lamp does not light up even if 1s is
passed, the muting function becomes invalid. When the muting lamp diagnosis function is invalid, the
muting function becomes valid 50ms after the input conditions of the muting sensor A (C) and B (D) were
satisfied.
<Reference>
It is recommended that two muting lamps should be connected in parallel. In this case, take care not to exceed
10W
.