2-4-3 Extension and Dismantling of Sensor (Series Connection)
This section describes the extension method of the series connection using the options.
For constructing the series connection, the following procedure is required.
<Mounting method of cable for series connection>
Replace the cable for series connection (
SFB-CSL
/
SFPB-CSL
).
1. Loosen the two M2.6 screws of the end cap on the main side sensor (emitter and receiver
to which the synchronization line has been connected), and then remove the end cap from
the sensor.
2. Insert the connector of the cable for series connection (
SFB-CSL
/
SFPB-CSL
) (op-
tional) into the connector. When inserting the connector, fit the cable into the groove of this
device.
3. Tighten each two M2.6 screws. The tightening torque should be 0.3N·m or less.
Do not lose any screws during extension / dismantling work.
Furthermore, do not mix emitters and receivers to mount in series connection.