background image

                                                                      Specification of excellent controller 

                                                                                                               

Page - 20 - 

17.    Troubleshooting Guide: 

 

18.    Warranty and after Sales Service 

The charge controller is warranted to be free from defects for a period of 

ONE (1) years from the date of shipment to the original end user. We will, 
at its option, repair or replace any such defective products. 

 

 

Claim procedure: 

Before  requesting  warranty  service,  check  the  Operation  Manual  to  be  certain 
that  there  is  a  problem  with  the  controller.  Return  the  defective  product  to  us 
with  shipping  charges  prepaid  if  problem  cannot  be  solved.  Provide  proof  of 
date  and  place  of  purchase.  To  obtain  rapid  service  under  this  warranty,  the 

 

Fault Phenomenon 

Reason 

Solution 

Connected to the 
battery, the controller 
does not work 

The battery voltage is too 
low 
 

Charger to charge 
the battery or 
replace the battery 

Connected to the 
battery, the controller 
does not output 

The battery voltage is below 
the release point 

Normal, wait for the 
system to charge to 
the recovery point 

Access photovoltaic panels, 
switch on    PV 

Remove the 
photovoltaic panels 

Controller is 1 minute output 
delay (battery voltage is   
normal) 

Normal 

The controller is not 
charging 

The voltage of Wind turbine 
and photovoltaic panels   
too low 

Observe When 
Wind or PV is 
strong enough 

The battery voltage is too 
high, has been in the 
overvoltage condition 

Normal 

Still no output when 
Batteries    rose to a 
recovery point ,from 
over-discharge point   

The controller has two 
minutes, delayed output 

observe and test 
after 1 minute 

The speed of the wind 
turbine is very low 

The wind speed is too low 

Observe When 
wind speed is high 

The battery is not connected, 
the controller starts the 
open-circuit protection 
function 

Securely connected 
again 

The battery voltage is too 
high, has been in the brake 
condition 

Observe after the 
Battery discharge 

Содержание SSWC-06-1224-TA

Страница 1: ...el No SSWC 06 1224 TA Version 5 0 Thank you very much for selecting our product This manual offers important information and suggestions with respect to installation use and troubleshooting etc Please...

Страница 2: ...ller 5 Step 1 Battery Wiring 5 Step 2 Loading Wiring 6 Step 3 Solar Module Wiring 7 Step 4 Wind turbine PMG Wiring 7 Step 5 Switch power wiring 8 Step 6 Accessories Option 8 Step 7 Confirmation for Wi...

Страница 3: ...er than controller rating accordingly 2 General Safety Information Please don t use low quality battery to avoid leakage rust or burn Please don t use thin or low quality cable to avoid leakage or fir...

Страница 4: ...light sensor voltage timer and so on 5 Protection Functions Solar cells reverse charging solar cells anti reverse connection Battery over charging over discharge battery anti reverse connection Over...

Страница 5: ...er the controller Loose power connections and or corroded wires may result in resistive connections that melt wire insulation burn surrounding materials or even cause fire Ensure tight connections and...

Страница 6: ...h the drilled holes in step 4 Secure the controller in place using the mounting screws 8 3 System connection with controller NOTE A recommended connection sequence has been provided for maximum safety...

Страница 7: ...ce will provide battery voltage to the loads DC loading could be LED lamp or monitor devices etc 1 Connect load1 positive and negative to the controller related terminals and connect load2 positive an...

Страница 8: ...ause severe shock or injury Cover the solar module s from the sun before installing solar wiring CAUTION 1 If you can not confirm the scientific and rational PV module connection by series or parallel...

Страница 9: ...e 2 wires from controller need connect to switch power Red wire is positive Black wire is negative polarity 2 Please make sure connection are correct with switch power related terminals 3 Switch power...

Страница 10: ...power terminals are tightened Step 8 Power up sequence after confirmation of connection 1 Turn on battery firstly 2 Turn on solar panel 3 Turn on wind turbine 4 Turn on DC loading 5 Turn on switch po...

Страница 11: ...ne 1 minute delay 4 If battery voltage lower than over discharge point no DC power output 5 As street lighting system while solar panel voltage higher than threshold voltage controller no DC power out...

Страница 12: ...batteries Eb mean power volume of battery with percent format Uw meaning voltage of wind turbine but this value is DC voltage which be rectified voltage from wind turbine output Iw charging current f...

Страница 13: ...d abnormal is troubleshooting the screen will automatically back to first browsing page content If the wind turbines in the brake protection status the screen display Tip Once the wind turbine brake a...

Страница 14: ...the value each press means increase or reduce 0 1V Press ENTER to choose 11 3 Press ENTER key to next page Press key or key to adjust the number each press means increase or reduce 0 1V If set time ea...

Страница 15: ...ill showing is 12v it was rectified value wind turbine output approximate 10vac 12v system will showing6 0v wind turbine output approximate 6vac Press key or key to adjust the number each press means...

Страница 16: ...battery to power up controller This is intent to make sure the program running in you done modified setting condition PLEASE MAKE SURE NO CONNECTIION WITH WIND TURBINE AND SOLAR PANEL BEFORE SETTING...

Страница 17: ...toT1 4 step T1 4 this process is balance of whole night time And turn off lamp while dawn This value would not show on LCD so this value is not adjustable Of course you could to cover this process by...

Страница 18: ...ischarge Recovery Voltage 12V 24V 12 0V 24 0V adjustable Over charge Voltage 12V 24V 15 0V 30 0V adjustable Over charge Recovery Voltage 12V 24V 13 5V 27 0V adjustable 14 4 Output Set up function Each...

Страница 19: ...rminals Inspect for loose broken or burnt wire connections Check and confirm that LCD is consistent with required Pay attention to any troubleshooting or error indication Take necessary corrective act...

Страница 20: ...battery 2 Connected to the battery the controller does not output The battery voltage is below the release point Normal wait for the system to charge to the recovery point Access photovoltaic panels s...

Страница 21: ...1 Damage by accident negligence abuse or improper use 2 PV or load current exceeding the rating of product 3 Unauthorized product modification attempted repair 4 Damage occurring during shipment 5 Dam...

Отзывы: