background image

                                                                      Specification of excellent controller 

                                                                                                               

Page - 5 - 

--- Wiring connection with system terminals   

--- LCD with green backlight   

--- ▲(+) setting key to increase value of parameters. 

--- ―Esc‖ key for existing system without save setting. 

--- ▼(-) setting key to reduce value of parameters. 

---  ―Enter‖  key  to  process  setting  condition  or  save  modification  of 

parameters. 

 

8. Installation Instructions 

8.1    General Installation Notes 

 

Read through the entire installation section first before beginning installation. 

 

Be very careful when working with batteries. Wear eye protection. Have fresh 

water available to wash and clean any contact with battery acid. 

 

Uses insulated tools and avoid placing metal objects near the batteries. 

 

Explosive battery gasses may be present during charging .Be certain there is 

      sufficient ventilation to release the gasses. 

 

Avoid direct sunlight and do not install in locations where water can enter the 

controller. 

 

Loose  power  connections  and  /or  corroded  wires  may  result  in  resistive 

connections  that  melt  wire  insulation,  burn  surrounding  materials,  or  even 
cause fire. Ensure tight connections and use cable clamps to secure cables and 
prevent them from swaying in mobile applications. 

 

Use with Gel, Sealed or Flooded batteries only. 

 

Battery  connection  may  be  wired  to  one  battery  or  a  bank  of  batteries.  The 

following  instructions  refer  to  a  singular  battery,  but  it  is  implied  that  the 
battery connection can be made to either one battery or a group of batteries in 
a battery bank. 

 

Select the system cables according to 3A/mm²

 current density. 

 

8.2    Mounting 

                    NOTE:  When  mounting  the  controller,  ensure  free  air  through  the 
controller heat sink fins. There should be at least 150mm of clearance above and 
below the controller to allow for cooling. If mounted in an enclosure, ventilation 
is highly recommended.   

   

                    WARNING:  Risk  of  explosion!  Never  install  the  controller  in  a 

sealed  enclose  with  flooded  batteries!  Do  not  install  in  a  confined  area 
where battery gas can accumulate. 

 

Содержание SSWC-06-1224-TA

Страница 1: ...el No SSWC 06 1224 TA Version 5 0 Thank you very much for selecting our product This manual offers important information and suggestions with respect to installation use and troubleshooting etc Please...

Страница 2: ...ller 5 Step 1 Battery Wiring 5 Step 2 Loading Wiring 6 Step 3 Solar Module Wiring 7 Step 4 Wind turbine PMG Wiring 7 Step 5 Switch power wiring 8 Step 6 Accessories Option 8 Step 7 Confirmation for Wi...

Страница 3: ...er than controller rating accordingly 2 General Safety Information Please don t use low quality battery to avoid leakage rust or burn Please don t use thin or low quality cable to avoid leakage or fir...

Страница 4: ...light sensor voltage timer and so on 5 Protection Functions Solar cells reverse charging solar cells anti reverse connection Battery over charging over discharge battery anti reverse connection Over...

Страница 5: ...er the controller Loose power connections and or corroded wires may result in resistive connections that melt wire insulation burn surrounding materials or even cause fire Ensure tight connections and...

Страница 6: ...h the drilled holes in step 4 Secure the controller in place using the mounting screws 8 3 System connection with controller NOTE A recommended connection sequence has been provided for maximum safety...

Страница 7: ...ce will provide battery voltage to the loads DC loading could be LED lamp or monitor devices etc 1 Connect load1 positive and negative to the controller related terminals and connect load2 positive an...

Страница 8: ...ause severe shock or injury Cover the solar module s from the sun before installing solar wiring CAUTION 1 If you can not confirm the scientific and rational PV module connection by series or parallel...

Страница 9: ...e 2 wires from controller need connect to switch power Red wire is positive Black wire is negative polarity 2 Please make sure connection are correct with switch power related terminals 3 Switch power...

Страница 10: ...power terminals are tightened Step 8 Power up sequence after confirmation of connection 1 Turn on battery firstly 2 Turn on solar panel 3 Turn on wind turbine 4 Turn on DC loading 5 Turn on switch po...

Страница 11: ...ne 1 minute delay 4 If battery voltage lower than over discharge point no DC power output 5 As street lighting system while solar panel voltage higher than threshold voltage controller no DC power out...

Страница 12: ...batteries Eb mean power volume of battery with percent format Uw meaning voltage of wind turbine but this value is DC voltage which be rectified voltage from wind turbine output Iw charging current f...

Страница 13: ...d abnormal is troubleshooting the screen will automatically back to first browsing page content If the wind turbines in the brake protection status the screen display Tip Once the wind turbine brake a...

Страница 14: ...the value each press means increase or reduce 0 1V Press ENTER to choose 11 3 Press ENTER key to next page Press key or key to adjust the number each press means increase or reduce 0 1V If set time ea...

Страница 15: ...ill showing is 12v it was rectified value wind turbine output approximate 10vac 12v system will showing6 0v wind turbine output approximate 6vac Press key or key to adjust the number each press means...

Страница 16: ...battery to power up controller This is intent to make sure the program running in you done modified setting condition PLEASE MAKE SURE NO CONNECTIION WITH WIND TURBINE AND SOLAR PANEL BEFORE SETTING...

Страница 17: ...toT1 4 step T1 4 this process is balance of whole night time And turn off lamp while dawn This value would not show on LCD so this value is not adjustable Of course you could to cover this process by...

Страница 18: ...ischarge Recovery Voltage 12V 24V 12 0V 24 0V adjustable Over charge Voltage 12V 24V 15 0V 30 0V adjustable Over charge Recovery Voltage 12V 24V 13 5V 27 0V adjustable 14 4 Output Set up function Each...

Страница 19: ...rminals Inspect for loose broken or burnt wire connections Check and confirm that LCD is consistent with required Pay attention to any troubleshooting or error indication Take necessary corrective act...

Страница 20: ...battery 2 Connected to the battery the controller does not output The battery voltage is below the release point Normal wait for the system to charge to the recovery point Access photovoltaic panels s...

Страница 21: ...1 Damage by accident negligence abuse or improper use 2 PV or load current exceeding the rating of product 3 Unauthorized product modification attempted repair 4 Damage occurring during shipment 5 Dam...

Отзывы: