12. Instructions for assembling and fitting the Solar collectors

Your solar collectors will arrive with the evacuated glass tubes installed. These evacuated glass tubes must be 
handled very carefully – Please note that these glass tubes never come into contact with the solar hot water, so if 
they ever got broken during the operational life of the solar hot water system, no solar hot water will ever get lost. 
They are easy to replace in-situ and do not require the system to be drained. This is because the Suntrap Solar 
Hot water system uses U-Tube solar collector technology which fully contains all the solar water within high 
pressure copper pipes which run inside the evacuated glass tubes.

As can be seen from the following pictures, the evacuated glass tubes slide into the 
collector manifold and are retained by plastic shrouds at the opposite end.

16 U-tubes make up each Solar collector

2 x Solar collectors are shown below

Part/n SET232

3 x Solar collectors are shown below

Part/n SET348

Pre-check list before starting to commission system:

Do not attempt Solar collector installation on a hot day – the Solar collectors and fittings 
will be too hot to touch

Turn off mains water supply valve

Make sure all connections are tightened

Make sure all fittings are securely tightened

Ensure Air vent valve has been opened at least 1 turn (and leave open)

Understand the importance of correctly purging the system – use of the purge valve at 
point G (and the Test plug in the Solar Controller Unit) – if air is left in the system, this 
valve will not open and recirculation will not take place: the Solar collectors and pipe 
work will pressurise, the pump will be put under strain and damage could result. 

WARNING – the water expelled from point G can be extremely hot and 
precautions must be taken.

Ensure that the temperature sensors are correctly placed and secure – again, if these 
are not sensing the correct temperatures, the Solar controller will not operate correctly, 
which could result in the PTR valve on the tank operating prematurely, and wasting 
water. (incorrect temperature detected and solar tank water gets too warm)

Turn on mains water supply valve. Turn on the cold water in DuoValve

Turn on Ball Valve at point D (handle in-line with pipe)

Check diagram below – connections and components to be installed in the order shown

OK to start commissioning system

Cold water in

DuoValve (on/off and one way)

500kpa Pressure Limiting Valve

Tank cold water in
(point H)

Mains water supply valve

11. Check List immediately prior to commissioning System

Содержание Sol-250LPG26-32

Страница 1: ...ORER requirements Gas Boost Models Sol 250NG26 32 Sol 250LPG26 32 Sol 315NG26 32 Sol 315LPG26 32 Sol 250NG26 48 Sol 250LPG26 48 Sol 315NG26 48 Sol 315LPG26 48 October 2012 issue 5 5 Suntrap Pty Ltd P...

Страница 2: ...arts 6 The Suntrap Solar Control Kit 7 Connections to the Suntrap Solar Collectors 8 Connections to the top of the Solar Hot Water Tank 9 Connections to the middle and bottom of the Solar Hot Water Ta...

Страница 3: ...ated tube collectors Configuration Annual Energy Saving 10 Year Small scale Technology Certificate Allocation Zone 1 Zone 2 Zone 3 Zone 4 Zone 1 Zone 2 Zone 3 Zone 4 Sol 250NG26 32 Sol 250LPG26 32 Sol...

Страница 4: ...ices must be kept in working order at all times High temperatures can exist in the solar pipes and precautions must be taken to avoid young children touching them If any power cords or plugs are damag...

Страница 5: ...r heating obtained from the sun Suntrap systems are certified to use continuous electrical boosting Thermostat setting Electric Boost A high tank temperature setting active during boost times should b...

Страница 6: ...Hot water kit and all components must be installed maintained and operated as per instructions otherwise all warranties are null and void 3 Suntrap Solarius Solar Hot Water Kits Parts Supplied The Sun...

Страница 7: ...16 x evacuated glass tubes Part n SSF003 2 x sections of galvanised steel for Roof Frame top bottom and 4 x stainless steel straps Part n MOU003 12 x brackets 12 x spring clamps bolts and washers to...

Страница 8: ...stainless steel solar hot water tank with middle element 3 6 KW heating element or Part n E315ME 1 x 315 litre Everlast stainless steel solar hot water tank with middle element 3 6 KW heating element...

Страница 9: ...d Solar Tanks FCV001 Flow Control Valve and Check Valve assemblies Detail of Flow control Valve Part of FCV001 SSF003 Galvanised Steel Frame and Stainless Steel Roof straps SET348 3 x Solar Collectors...

Страница 10: ...ion boot SWR00A Solar Collector outlet assembly with Temperature Sensor Receptacle SWI00A Solar Collector inlet assembly NRV00A Solar Return Inlet Non Return Valve with Purge Valve assembly Solar hot...

Страница 11: ...and Red Dots on the Solar Collectors have no significance apart from a means of identification Solar Hot Water tank Solar Pump Solar Control Unit Solar Collector Solar Collector Hot Water Out to taps...

Страница 12: ...k Valve assembly W Flow Marked D L K 5 The Suntrap Solar Control Kit Electric The Solar Control Kit contains the following items 1 The Solar Pump 2 The Solar Controller Unit 3 Ball Valve inlet to sola...

Страница 13: ...P To Point T on Tempering Valve H From Solar Collector Outlet K Solar Outlet Return To Solar Collector inlet L via Solar Pump Solar Recycle M and N 6 Completed installation views of assembled parts So...

Страница 14: ...let side of the Solar Collector Point K Using 19mm thickness insulation connect a 15mm copper pipe from the Solar Control Kit point E to the inlet side of the solar collectors point L Water Flow Water...

Страница 15: ...int V part of P N BSR00A used as a blanking plug as this port is not used The bottom picture shows the Solar Hot water out connector and the Gas Booster connection kit Connections to the top of the El...

Страница 16: ...alve Point D H P G 10 The completed Solar Hot Water Tank assembly The Tank and Solar control kit must be positioned close together The Solar tank must sit on firm and level ground If the solar tank is...

Страница 17: ...fittings will be too hot to touch Turn off mains water supply valve Make sure all connections are tightened Make sure all fittings are securely tightened Ensure Air vent valve has been opened at least...

Страница 18: ...et 20mm from the edge of the bottom rail Clamp bracket into bottom rail Bolt collector to bracket Position 2nd collector next to the 1st collector and use the coupling to join the tops of the two coll...

Страница 19: ...use Armaflex material 19mm thickness insulation between the Solar Preheat Tank and the Gas Booster Position the Solar Hot Water tank on firm and level ground near an electrical supply Screw the Shut o...

Страница 20: ...on refer to the Gas Boost heater manufacturers instructions Set the Gas Boost temperature to 70 degrees centigrade Check all fittings and tighten as necessary 13 Completing the Installation cont Ensur...

Страница 21: ...e piece SL I 1500 Collector tubes U 1500 16 MODEL Suntrap Evacuated U Tube Solar Collector Features Simple structure and stable operation Utilization all year round even in cold climates Can operate w...

Страница 22: ...Suntrap Solar Hot water systems which have arisen due to faulty materials Please call Suntrap Solar Australia for all Warranty claims Suntrap Pty Ltd ABN 87 117 052 856 PO Box 3164 Dural NSW 2158 Tel...

Страница 23: ...ed you are entitled to an exchange or refund upon return of the product s to Suntrap within 30 days of purchase 2 Labour charges and shipping charges will not be refunded 3 If you change your mind Sun...

Отзывы: